Coefficient of Transmissibility is defined as the rate of flow of water in gallons per day through a vertical strip of the aquifer. Check FAQs
Tenvi=Q2πstlog((Rwr),e)
Tenvi - Coefficient of Transmissibility?Q - Discharge?st - Total Drawdown?Rw - Radius of Influence?r - Radius of Well?π - Archimedes' constant?

Coefficient of Transmissibility given Confined Aquifer Discharge Example

With values
With units
Only example

Here is how the Coefficient of Transmissibility given Confined Aquifer Discharge equation looks like with Values.

Here is how the Coefficient of Transmissibility given Confined Aquifer Discharge equation looks like with Units.

Here is how the Coefficient of Transmissibility given Confined Aquifer Discharge equation looks like.

1.4151Edit=1.01Edit23.14160.83Editlog((8.6Edit7.5Edit),e)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Coefficient of Transmissibility given Confined Aquifer Discharge

Coefficient of Transmissibility given Confined Aquifer Discharge Solution

Follow our step by step solution on how to calculate Coefficient of Transmissibility given Confined Aquifer Discharge?

FIRST Step Consider the formula
Tenvi=Q2πstlog((Rwr),e)
Next Step Substitute values of Variables
Tenvi=1.01m³/s2π0.83mlog((8.6m7.5m),e)
Next Step Substitute values of Constants
Tenvi=1.01m³/s23.14160.83mlog((8.6m7.5m),e)
Next Step Prepare to Evaluate
Tenvi=1.0123.14160.83log((8.67.5),e)
Next Step Evaluate
Tenvi=1.41510762430351m²/s
LAST Step Rounding Answer
Tenvi=1.4151m²/s

Coefficient of Transmissibility given Confined Aquifer Discharge Formula Elements

Variables
Constants
Functions
Coefficient of Transmissibility
Coefficient of Transmissibility is defined as the rate of flow of water in gallons per day through a vertical strip of the aquifer.
Symbol: Tenvi
Measurement: Kinematic ViscosityUnit: m²/s
Note: Value should be greater than 0.
Discharge
Discharge is the flow rate of water that is extracted from or injected into a well.
Symbol: Q
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value can be positive or negative.
Total Drawdown
The Total Drawdown is defined as the reduction in hydraulic head observed at a well in an aquifer, typically due to pumping a well as part of an aquifer test or well test.
Symbol: st
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Radius of Influence
Radius of Influence measured from the center of the well to the point where drawdown curve meets the original water table.
Symbol: Rw
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Radius of Well
Radius of Well is defined as the distance from center of well to its outer boundary.
Symbol: r
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Archimedes' constant
Archimedes' constant is a mathematical constant that represents the ratio of the circumference of a circle to its diameter.
Symbol: π
Value: 3.14159265358979323846264338327950288
log
Logarithmic function is an inverse function to exponentiation.
Syntax: log(Base, Number)

Other Formulas to find Coefficient of Transmissibility

​Go Coefficient of Transmissibility given Discharge in Confined Aquifer with Base 10
Tenvi=Q2.72(bw-hwell)log((Rwr),10)
​Go Coefficient of Transmissibility given Depth of Water in Two Wells
Tenvi=Q2.72(h2-h1)log((r2r1'),10)

How to Evaluate Coefficient of Transmissibility given Confined Aquifer Discharge?

Coefficient of Transmissibility given Confined Aquifer Discharge evaluator uses Coefficient of Transmissibility = Discharge/((2*pi*Total Drawdown)/(log((Radius of Influence/Radius of Well),e))) to evaluate the Coefficient of Transmissibility, The Coefficient of Transmissibility given Confined Aquifer Discharge formula is defined as the value of coefficient of transmissibility when we have prior information of confined aquifer discharge. Coefficient of Transmissibility is denoted by Tenvi symbol.

How to evaluate Coefficient of Transmissibility given Confined Aquifer Discharge using this online evaluator? To use this online evaluator for Coefficient of Transmissibility given Confined Aquifer Discharge, enter Discharge (Q), Total Drawdown (st), Radius of Influence (Rw) & Radius of Well (r) and hit the calculate button.

FAQs on Coefficient of Transmissibility given Confined Aquifer Discharge

What is the formula to find Coefficient of Transmissibility given Confined Aquifer Discharge?
The formula of Coefficient of Transmissibility given Confined Aquifer Discharge is expressed as Coefficient of Transmissibility = Discharge/((2*pi*Total Drawdown)/(log((Radius of Influence/Radius of Well),e))). Here is an example- 1.415108 = 1.01/((2*pi*0.83)/(log((8.6/7.5),e))).
How to calculate Coefficient of Transmissibility given Confined Aquifer Discharge?
With Discharge (Q), Total Drawdown (st), Radius of Influence (Rw) & Radius of Well (r) we can find Coefficient of Transmissibility given Confined Aquifer Discharge using the formula - Coefficient of Transmissibility = Discharge/((2*pi*Total Drawdown)/(log((Radius of Influence/Radius of Well),e))). This formula also uses Archimedes' constant and Logarithmic Inverse (log) function(s).
What are the other ways to Calculate Coefficient of Transmissibility?
Here are the different ways to Calculate Coefficient of Transmissibility-
  • Coefficient of Transmissibility=Discharge/((2.72*(Aquifer Thickness-Depth of Water in Well))/(log((Radius of Influence/Radius of Well),10)))OpenImg
  • Coefficient of Transmissibility=Discharge/((2.72*(Depth of Water 2-Depth of Water 1))/(log((Radial Distance at Observation Well 2/Radial Distance at Well 1),10)))OpenImg
Can the Coefficient of Transmissibility given Confined Aquifer Discharge be negative?
No, the Coefficient of Transmissibility given Confined Aquifer Discharge, measured in Kinematic Viscosity cannot be negative.
Which unit is used to measure Coefficient of Transmissibility given Confined Aquifer Discharge?
Coefficient of Transmissibility given Confined Aquifer Discharge is usually measured using the Square Meter per Second[m²/s] for Kinematic Viscosity. Square Meter per Hour[m²/s], Square Centimeter per Second[m²/s], Square Millimeter per Second[m²/s] are the few other units in which Coefficient of Transmissibility given Confined Aquifer Discharge can be measured.
Copied!