Fx Copy
LaTeX Copy
Runoff Coefficient is a dimensionless coefficient relating the amount of runoff to the amount of precipitation received. Check FAQs
Cr=Qp(13.6)itcpAD
Cr - Runoff Coefficient?Qp - Peak Discharge?itcp - Mean Intensity of Precipitation?AD - Drainage Area?

Coefficient of Runoff when Peak Discharge for Field Application is Considered Example

With values
With units
Only example

Here is how the Coefficient of Runoff when Peak Discharge for Field Application is Considered equation looks like with Values.

Here is how the Coefficient of Runoff when Peak Discharge for Field Application is Considered equation looks like with Units.

Here is how the Coefficient of Runoff when Peak Discharge for Field Application is Considered equation looks like.

0.5Edit=4Edit(13.6)5.76Edit18Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Engineering Hydrology » fx Coefficient of Runoff when Peak Discharge for Field Application is Considered

Coefficient of Runoff when Peak Discharge for Field Application is Considered Solution

Follow our step by step solution on how to calculate Coefficient of Runoff when Peak Discharge for Field Application is Considered?

FIRST Step Consider the formula
Cr=Qp(13.6)itcpAD
Next Step Substitute values of Variables
Cr=4m³/s(13.6)5.76mm/h18km²
Next Step Convert Units
Cr=4m³/s(13.6)1.6E-6m/s1.8E+7
Next Step Prepare to Evaluate
Cr=4(13.6)1.6E-61.8E+7
LAST Step Evaluate
Cr=0.5

Coefficient of Runoff when Peak Discharge for Field Application is Considered Formula Elements

Variables
Runoff Coefficient
Runoff Coefficient is a dimensionless coefficient relating the amount of runoff to the amount of precipitation received.
Symbol: Cr
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Peak Discharge
Peak Discharge is the maximum volume flow rate passing a particular location during an event.
Symbol: Qp
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Mean Intensity of Precipitation
Mean Intensity of Precipitation (mm/hr) for a duration equal to tc and an exceedance probability P.
Symbol: itcp
Measurement: SpeedUnit: mm/h
Note: Value should be greater than 0.
Drainage Area
Drainage Area is the total surface area, where the water from rain which is not absorbed into the ground flows over the ground surface, back into streams, to finally reach that point.
Symbol: AD
Measurement: AreaUnit: km²
Note: Value can be positive or negative.

Other Formulas to find Runoff Coefficient

​Go Coefficient of Runoff when Peak Value is Considered
Cr=QpADi

Other formulas in Rational Method to Estimate the Flood Peak category

​Go Value of Peak Discharge
Qp=CrADi
​Go Drainage Area when Peak Discharge is Considered
AD=QpiCr
​Go Intensity of Rainfall when Peak Discharge is Considered
i=QpCrAD
​Go Peak Discharge for Field Application
Qp=(13.6)CritcpAD

How to Evaluate Coefficient of Runoff when Peak Discharge for Field Application is Considered?

Coefficient of Runoff when Peak Discharge for Field Application is Considered evaluator uses Runoff Coefficient = Peak Discharge/((1/3.6)*Mean Intensity of Precipitation*Drainage Area) to evaluate the Runoff Coefficient, The Coefficient of Runoff when Peak Discharge for Field Application is Considered formula is defined as the dimensionless coefficient relating the amount of runoff to the amount of precipitation received. Runoff Coefficient is denoted by Cr symbol.

How to evaluate Coefficient of Runoff when Peak Discharge for Field Application is Considered using this online evaluator? To use this online evaluator for Coefficient of Runoff when Peak Discharge for Field Application is Considered, enter Peak Discharge (Qp), Mean Intensity of Precipitation (itcp) & Drainage Area (AD) and hit the calculate button.

FAQs on Coefficient of Runoff when Peak Discharge for Field Application is Considered

What is the formula to find Coefficient of Runoff when Peak Discharge for Field Application is Considered?
The formula of Coefficient of Runoff when Peak Discharge for Field Application is Considered is expressed as Runoff Coefficient = Peak Discharge/((1/3.6)*Mean Intensity of Precipitation*Drainage Area). Here is an example- 0.5 = 4/((1/3.6)*1.6E-06*18000000).
How to calculate Coefficient of Runoff when Peak Discharge for Field Application is Considered?
With Peak Discharge (Qp), Mean Intensity of Precipitation (itcp) & Drainage Area (AD) we can find Coefficient of Runoff when Peak Discharge for Field Application is Considered using the formula - Runoff Coefficient = Peak Discharge/((1/3.6)*Mean Intensity of Precipitation*Drainage Area).
What are the other ways to Calculate Runoff Coefficient?
Here are the different ways to Calculate Runoff Coefficient-
  • Runoff Coefficient=Peak Discharge/(Drainage Area*Intensity of Rainfall)OpenImg
Copied!