Fx Copy
LaTeX Copy
Coefficient of Permeability in Well Hydraulics of soil in well hydraulics describes how easily a liquid will move through the soil. Check FAQs
KWH=Q2.72bwStwlog((Rwr),10)
KWH - Coefficient of Permeability in Well Hydraulics?Q - Discharge?bw - Aquifer Thickness?Stw - Total Drawdown in Well?Rw - Radius of Influence?r - Radius of Well?

Coefficient of Permeability given Confined Aquifer Discharge with Base 10 Example

With values
With units
Only example

Here is how the Coefficient of Permeability given Confined Aquifer Discharge with Base 10 equation looks like with Values.

Here is how the Coefficient of Permeability given Confined Aquifer Discharge with Base 10 equation looks like with Units.

Here is how the Coefficient of Permeability given Confined Aquifer Discharge with Base 10 equation looks like.

8.9555Edit=1.01Edit2.7214.15Edit4.93Editlog((8.6Edit7.5Edit),10)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Coefficient of Permeability given Confined Aquifer Discharge with Base 10

Coefficient of Permeability given Confined Aquifer Discharge with Base 10 Solution

Follow our step by step solution on how to calculate Coefficient of Permeability given Confined Aquifer Discharge with Base 10?

FIRST Step Consider the formula
KWH=Q2.72bwStwlog((Rwr),10)
Next Step Substitute values of Variables
KWH=1.01m³/s2.7214.15m4.93mlog((8.6m7.5m),10)
Next Step Prepare to Evaluate
KWH=1.012.7214.154.93log((8.67.5),10)
Next Step Evaluate
KWH=0.0895552101052537m/s
Next Step Convert to Output's Unit
KWH=8.95552101052537cm/s
LAST Step Rounding Answer
KWH=8.9555cm/s

Coefficient of Permeability given Confined Aquifer Discharge with Base 10 Formula Elements

Variables
Functions
Coefficient of Permeability in Well Hydraulics
Coefficient of Permeability in Well Hydraulics of soil in well hydraulics describes how easily a liquid will move through the soil.
Symbol: KWH
Measurement: SpeedUnit: cm/s
Note: Value should be greater than 0.
Discharge
Discharge is the flow rate of water that is extracted from or injected into a well.
Symbol: Q
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value can be positive or negative.
Aquifer Thickness
Aquifer Thickness (at Midpoint between Equipotential lines) or otherwise is the thickness of aquifer in which the pore spaces of rock forming the aquifer may or may not be with water.
Symbol: bw
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Total Drawdown in Well
Total Drawdown in Well is defined as the reduction in hydraulic head observed at a well in an aquifer, typically due to pumping a well as part of an aquifer test or well test.
Symbol: Stw
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Radius of Influence
Radius of Influence measured from the center of the well to the point where drawdown curve meets the original water table.
Symbol: Rw
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Radius of Well
Radius of Well is defined as the distance from center of well to its outer boundary.
Symbol: r
Measurement: LengthUnit: m
Note: Value should be greater than 0.
log
Logarithmic function is an inverse function to exponentiation.
Syntax: log(Base, Number)

Other Formulas to find Coefficient of Permeability in Well Hydraulics

​Go Coefficient of Permeability given Confined Aquifer Discharge
KWH=Q2πbwstlog((Rwr),e)

Other formulas in Coefficient of Permeability category

​Go Coefficient of Permeability given Depth of Water in Two Wells
Kw=Q2.72bp(h2-h1)log((r2r1),10)

How to Evaluate Coefficient of Permeability given Confined Aquifer Discharge with Base 10?

Coefficient of Permeability given Confined Aquifer Discharge with Base 10 evaluator uses Coefficient of Permeability in Well Hydraulics = Discharge/((2.72*Aquifer Thickness*Total Drawdown in Well)/(log((Radius of Influence/Radius of Well),10))) to evaluate the Coefficient of Permeability in Well Hydraulics, The Coefficient of Permeability given Confined Aquifer Discharge with Base 10 formula is defined as the value of coefficient of permeability with base 10, when we have prior information of confined aquifer discharge. Coefficient of Permeability in Well Hydraulics is denoted by KWH symbol.

How to evaluate Coefficient of Permeability given Confined Aquifer Discharge with Base 10 using this online evaluator? To use this online evaluator for Coefficient of Permeability given Confined Aquifer Discharge with Base 10, enter Discharge (Q), Aquifer Thickness (bw), Total Drawdown in Well (Stw), Radius of Influence (Rw) & Radius of Well (r) and hit the calculate button.

FAQs on Coefficient of Permeability given Confined Aquifer Discharge with Base 10

What is the formula to find Coefficient of Permeability given Confined Aquifer Discharge with Base 10?
The formula of Coefficient of Permeability given Confined Aquifer Discharge with Base 10 is expressed as Coefficient of Permeability in Well Hydraulics = Discharge/((2.72*Aquifer Thickness*Total Drawdown in Well)/(log((Radius of Influence/Radius of Well),10))). Here is an example- 844.8041 = 1.01/((2.72*14.15*4.93)/(log((8.6/7.5),10))).
How to calculate Coefficient of Permeability given Confined Aquifer Discharge with Base 10?
With Discharge (Q), Aquifer Thickness (bw), Total Drawdown in Well (Stw), Radius of Influence (Rw) & Radius of Well (r) we can find Coefficient of Permeability given Confined Aquifer Discharge with Base 10 using the formula - Coefficient of Permeability in Well Hydraulics = Discharge/((2.72*Aquifer Thickness*Total Drawdown in Well)/(log((Radius of Influence/Radius of Well),10))). This formula also uses Logarithmic Inverse (log) function(s).
What are the other ways to Calculate Coefficient of Permeability in Well Hydraulics?
Here are the different ways to Calculate Coefficient of Permeability in Well Hydraulics-
  • Coefficient of Permeability in Well Hydraulics=Discharge/((2*pi*Aquifer Thickness*Total Drawdown)/(log((Radius of Influence/Radius of Well),e)))OpenImg
Can the Coefficient of Permeability given Confined Aquifer Discharge with Base 10 be negative?
No, the Coefficient of Permeability given Confined Aquifer Discharge with Base 10, measured in Speed cannot be negative.
Which unit is used to measure Coefficient of Permeability given Confined Aquifer Discharge with Base 10?
Coefficient of Permeability given Confined Aquifer Discharge with Base 10 is usually measured using the Centimeter per Second[cm/s] for Speed. Meter per Second[cm/s], Meter per Minute[cm/s], Meter per Hour[cm/s] are the few other units in which Coefficient of Permeability given Confined Aquifer Discharge with Base 10 can be measured.
Copied!