Coefficient of Performance of Absorption System Formula

Fx Copy
LaTeX Copy
Coefficient of Performance of absorption system is defined as Cooling Duty(kW)/Generator Heating Duty(kW). Check FAQs
coeff_v_abs=Tevp(Tgen-Tcond)Tgen(Tcond-Tevp)
coeff_v_abs - Coefficient of Performance of absorption system?Tevp - Evaporator Temperature?Tgen - Generator temperature?Tcond - Condenser temperature?

Coefficient of Performance of Absorption System Example

With values
With units
Only example

Here is how the Coefficient of Performance of Absorption System equation looks like with Values.

Here is how the Coefficient of Performance of Absorption System equation looks like with Units.

Here is how the Coefficient of Performance of Absorption System equation looks like.

-0.4122Edit=202Edit(250Edit-300Edit)250Edit(300Edit-202Edit)
You are here -
HomeIcon Home » Category Engineering » Category Mechanical » Category Thermodynamics » fx Coefficient of Performance of Absorption System

Coefficient of Performance of Absorption System Solution

Follow our step by step solution on how to calculate Coefficient of Performance of Absorption System?

FIRST Step Consider the formula
coeff_v_abs=Tevp(Tgen-Tcond)Tgen(Tcond-Tevp)
Next Step Substitute values of Variables
coeff_v_abs=202K(250K-300K)250K(300K-202K)
Next Step Prepare to Evaluate
coeff_v_abs=202(250-300)250(300-202)
Next Step Evaluate
coeff_v_abs=-0.412244897959184
LAST Step Rounding Answer
coeff_v_abs=-0.4122

Coefficient of Performance of Absorption System Formula Elements

Variables
Coefficient of Performance of absorption system
Coefficient of Performance of absorption system is defined as Cooling Duty(kW)/Generator Heating Duty(kW).
Symbol: coeff_v_abs
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Evaporator Temperature
Evaporator temperature is the temperature of the evaporator.
Symbol: Tevp
Measurement: TemperatureUnit: K
Note: Value can be positive or negative.
Generator temperature
Generator temperature is the temperature of the generator.
Symbol: Tgen
Measurement: TemperatureUnit: K
Note: Value can be positive or negative.
Condenser temperature
Condenser temperature is the temperature of the condenser.
Symbol: Tcond
Measurement: TemperatureUnit: K
Note: Value can be positive or negative.

Other formulas in Coefficient of Performance category

​Go Coefficient of Performance of Heat Pump using Heat in Cold and Hot Reservoir
COPHP=QHQH-QL
​Go Coefficient of Performance of Heat Pump using Work and Heat in Cold Reservoir
COPHP(CR)=QHWnet
​Go Coefficient of Performance of Refrigerator
COPRefrigerator=QlowRW
​Go Coefficient of Performance of Refrigerator given Heat in Cold and Hot Reservoir
COPR=QLQH-QL

How to Evaluate Coefficient of Performance of Absorption System?

Coefficient of Performance of Absorption System evaluator uses Coefficient of Performance of absorption system = (Evaporator Temperature*(Generator temperature-Condenser temperature))/(Generator temperature*(Condenser temperature-Evaporator Temperature)) to evaluate the Coefficient of Performance of absorption system, Coefficient of Performance of Absorption System measures its efficiency in producing cooling or refrigeration. Absorption systems are used for refrigeration by utilizing a heat source to drive the refrigeration cycle, making them energy-efficient alternatives in certain applications. Coefficient of Performance of absorption system is denoted by coeff_v_abs symbol.

How to evaluate Coefficient of Performance of Absorption System using this online evaluator? To use this online evaluator for Coefficient of Performance of Absorption System, enter Evaporator Temperature (Tevp), Generator temperature (Tgen) & Condenser temperature (Tcond) and hit the calculate button.

FAQs on Coefficient of Performance of Absorption System

What is the formula to find Coefficient of Performance of Absorption System?
The formula of Coefficient of Performance of Absorption System is expressed as Coefficient of Performance of absorption system = (Evaporator Temperature*(Generator temperature-Condenser temperature))/(Generator temperature*(Condenser temperature-Evaporator Temperature)). Here is an example- -0.412245 = (202*(250-300))/(250*(300-202)).
How to calculate Coefficient of Performance of Absorption System?
With Evaporator Temperature (Tevp), Generator temperature (Tgen) & Condenser temperature (Tcond) we can find Coefficient of Performance of Absorption System using the formula - Coefficient of Performance of absorption system = (Evaporator Temperature*(Generator temperature-Condenser temperature))/(Generator temperature*(Condenser temperature-Evaporator Temperature)).
Copied!