Fx Copy
LaTeX Copy
The Coefficient of Permeability of soil describes how easily a liquid will move through the soil. Check FAQs
K=((Rh2)(L-x)x)
K - Coefficient of Permeability?R - Natural Recharge?h - Water Table Profile?L - Length between Tile Drain?x - Flow in 'x' Direction?

Coefficient of Aquifer Permeability given Water Table Profile Example

With values
With units
Only example

Here is how the Coefficient of Aquifer Permeability given Water Table Profile equation looks like with Values.

Here is how the Coefficient of Aquifer Permeability given Water Table Profile equation looks like with Units.

Here is how the Coefficient of Aquifer Permeability given Water Table Profile equation looks like.

8Edit=((16Edit4Edit2)(6Edit-2Edit)2Edit)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Engineering Hydrology » fx Coefficient of Aquifer Permeability given Water Table Profile

Coefficient of Aquifer Permeability given Water Table Profile Solution

Follow our step by step solution on how to calculate Coefficient of Aquifer Permeability given Water Table Profile?

FIRST Step Consider the formula
K=((Rh2)(L-x)x)
Next Step Substitute values of Variables
K=((16m³/s4m2)(6m-2m³/s)2m³/s)
Next Step Prepare to Evaluate
K=((1642)(6-2)2)
Next Step Evaluate
K=0.08m/s
LAST Step Convert to Output's Unit
K=8cm/s

Coefficient of Aquifer Permeability given Water Table Profile Formula Elements

Variables
Coefficient of Permeability
The Coefficient of Permeability of soil describes how easily a liquid will move through the soil.
Symbol: K
Measurement: SpeedUnit: cm/s
Note: Value should be greater than 0.
Natural Recharge
The Natural Recharge is a process by which groundwater is replenished naturally when precipitation infiltrates the ground, moving through the soil and rock layers until it reaches the water table.
Symbol: R
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value can be positive or negative.
Water Table Profile
The Water Table Profile refers to the depth of water table below aquifer.
Symbol: h
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Length between Tile Drain
The Length between Tile Drain refers to the approximate expression to the water table profile on a horizontal impervious boundary.
Symbol: L
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Flow in 'x' Direction
The Flow in 'x' Direction refers to the one-dimensional Dupit flow with recharge representation.
Symbol: x
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value can be positive or negative.

Other Formulas to find Coefficient of Permeability

​Go Coefficient of Aquifer Permeability given Maximum Height of Water Table
K=RL2(2hm)2
​Go Coefficient of Aquifer Permeability considering Discharge per Unit Width of Aquifer
K=Q2Lstream(ho2)-(h12)

Other formulas in One Dimensional Dupit's Flow with Recharge category

​Go Equation of Head for Unconfined Aquifer on Horizontal Impervious Base
h=(-Rx2K)-((ho2-h12-(RLstream2K)Lstream)x)+ho2
​Go Equation for Water Divide
a=(Lstream2)-(KR)(ho2-h122Lstream)
​Go Discharge per Unit Width of Aquifer at any Location x
qx=R(x-(Lstream2))+(K2Lstream)(ho2-h12)
​Go Discharge at Downstream Water Body of Catchment
q1=(RLstream2)+((K2Lstream)(ho2-h12))

How to Evaluate Coefficient of Aquifer Permeability given Water Table Profile?

Coefficient of Aquifer Permeability given Water Table Profile evaluator uses Coefficient of Permeability = ((Natural Recharge/Water Table Profile^2)*(Length between Tile Drain-Flow in 'x' Direction)*Flow in 'x' Direction) to evaluate the Coefficient of Permeability, The Coefficient of Aquifer Permeability given Water Table Profile formula is defined as the measure of the capacity of the soil through which the water can easily flow through it. Coefficient of Permeability is denoted by K symbol.

How to evaluate Coefficient of Aquifer Permeability given Water Table Profile using this online evaluator? To use this online evaluator for Coefficient of Aquifer Permeability given Water Table Profile, enter Natural Recharge (R), Water Table Profile (h), Length between Tile Drain (L) & Flow in 'x' Direction (x) and hit the calculate button.

FAQs on Coefficient of Aquifer Permeability given Water Table Profile

What is the formula to find Coefficient of Aquifer Permeability given Water Table Profile?
The formula of Coefficient of Aquifer Permeability given Water Table Profile is expressed as Coefficient of Permeability = ((Natural Recharge/Water Table Profile^2)*(Length between Tile Drain-Flow in 'x' Direction)*Flow in 'x' Direction). Here is an example- 15.44282 = ((16/water_table_profile_^2)*(6-2)*2).
How to calculate Coefficient of Aquifer Permeability given Water Table Profile?
With Natural Recharge (R), Water Table Profile (h), Length between Tile Drain (L) & Flow in 'x' Direction (x) we can find Coefficient of Aquifer Permeability given Water Table Profile using the formula - Coefficient of Permeability = ((Natural Recharge/Water Table Profile^2)*(Length between Tile Drain-Flow in 'x' Direction)*Flow in 'x' Direction).
What are the other ways to Calculate Coefficient of Permeability?
Here are the different ways to Calculate Coefficient of Permeability-
  • Coefficient of Permeability=(Natural Recharge*Length between Tile Drain^2)/(2*Maximum Height of Water Table)^2OpenImg
  • Coefficient of Permeability=(Discharge*2*Length between Upstream and Downstream)/((Piezometric Head at Upstream End^2)-(Piezometric Head at Downstream End^2))OpenImg
Can the Coefficient of Aquifer Permeability given Water Table Profile be negative?
No, the Coefficient of Aquifer Permeability given Water Table Profile, measured in Speed cannot be negative.
Which unit is used to measure Coefficient of Aquifer Permeability given Water Table Profile?
Coefficient of Aquifer Permeability given Water Table Profile is usually measured using the Centimeter per Second[cm/s] for Speed. Meter per Second[cm/s], Meter per Minute[cm/s], Meter per Hour[cm/s] are the few other units in which Coefficient of Aquifer Permeability given Water Table Profile can be measured.
Copied!