Fx Copy
LaTeX Copy
The Coefficient of Permeability of soil describes how easily a liquid will move through the soil. Check FAQs
K=Q2Lstream(ho2)-(h12)
K - Coefficient of Permeability?Q - Discharge?Lstream - Length between Upstream and Downstream?ho - Piezometric Head at Upstream End?h1 - Piezometric Head at Downstream End?

Coefficient of Aquifer Permeability considering Discharge per Unit Width of Aquifer Example

With values
With units
Only example

Here is how the Coefficient of Aquifer Permeability considering Discharge per Unit Width of Aquifer equation looks like with Values.

Here is how the Coefficient of Aquifer Permeability considering Discharge per Unit Width of Aquifer equation looks like with Units.

Here is how the Coefficient of Aquifer Permeability considering Discharge per Unit Width of Aquifer equation looks like.

8.9361Edit=1.3Edit24.09Edit(12Edit2)-(5Edit2)
You are here -

Coefficient of Aquifer Permeability considering Discharge per Unit Width of Aquifer Solution

Follow our step by step solution on how to calculate Coefficient of Aquifer Permeability considering Discharge per Unit Width of Aquifer?

FIRST Step Consider the formula
K=Q2Lstream(ho2)-(h12)
Next Step Substitute values of Variables
K=1.3m³/s24.09m(12m2)-(5m2)
Next Step Prepare to Evaluate
K=1.324.09(122)-(52)
Next Step Evaluate
K=0.0893613445378151m/s
Next Step Convert to Output's Unit
K=8.93613445378151cm/s
LAST Step Rounding Answer
K=8.9361cm/s

Coefficient of Aquifer Permeability considering Discharge per Unit Width of Aquifer Formula Elements

Variables
Coefficient of Permeability
The Coefficient of Permeability of soil describes how easily a liquid will move through the soil.
Symbol: K
Measurement: SpeedUnit: cm/s
Note: Value should be greater than 0.
Discharge
The Discharge refers to the volumetric flow rate of water that is transported through a given cross-sectional area. It includes any suspended solids, dissolved chemicals, or biologic material.
Symbol: Q
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Length between Upstream and Downstream
The Length between Upstream and Downstream refers to the horizontal base with a difference in surface elevations.
Symbol: Lstream
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Piezometric Head at Upstream End
The Piezometric Head at Upstream End refers to the specific measurement of liquid pressure above a vertical datum.
Symbol: ho
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Piezometric Head at Downstream End
The Piezometric Head at Downstream End refers to the specific measurement of liquid pressure above a vertical datum.
Symbol: h1
Measurement: LengthUnit: m
Note: Value can be positive or negative.

Other Formulas to find Coefficient of Permeability

​Go Coefficient of Aquifer Permeability given Maximum Height of Water Table
K=RL2(2hm)2
​Go Coefficient of Aquifer Permeability given Water Table Profile
K=((Rh2)(L-x)x)

Other formulas in One Dimensional Dupit's Flow with Recharge category

​Go Equation of Head for Unconfined Aquifer on Horizontal Impervious Base
h=(-Rx2K)-((ho2-h12-(RLstream2K)Lstream)x)+ho2
​Go Equation for Water Divide
a=(Lstream2)-(KR)(ho2-h122Lstream)
​Go Discharge per Unit Width of Aquifer at any Location x
qx=R(x-(Lstream2))+(K2Lstream)(ho2-h12)
​Go Discharge at Downstream Water Body of Catchment
q1=(RLstream2)+((K2Lstream)(ho2-h12))

How to Evaluate Coefficient of Aquifer Permeability considering Discharge per Unit Width of Aquifer?

Coefficient of Aquifer Permeability considering Discharge per Unit Width of Aquifer evaluator uses Coefficient of Permeability = (Discharge*2*Length between Upstream and Downstream)/((Piezometric Head at Upstream End^2)-(Piezometric Head at Downstream End^2)) to evaluate the Coefficient of Permeability, The Coefficient of Aquifer Permeability considering Discharge per Unit Width of Aquifer formula is defined as the measure of the capacity of the soil with which the water can easily flow through it. Coefficient of Permeability is denoted by K symbol.

How to evaluate Coefficient of Aquifer Permeability considering Discharge per Unit Width of Aquifer using this online evaluator? To use this online evaluator for Coefficient of Aquifer Permeability considering Discharge per Unit Width of Aquifer, enter Discharge (Q), Length between Upstream and Downstream (Lstream), Piezometric Head at Upstream End (ho) & Piezometric Head at Downstream End (h1) and hit the calculate button.

FAQs on Coefficient of Aquifer Permeability considering Discharge per Unit Width of Aquifer

What is the formula to find Coefficient of Aquifer Permeability considering Discharge per Unit Width of Aquifer?
The formula of Coefficient of Aquifer Permeability considering Discharge per Unit Width of Aquifer is expressed as Coefficient of Permeability = (Discharge*2*Length between Upstream and Downstream)/((Piezometric Head at Upstream End^2)-(Piezometric Head at Downstream End^2)). Here is an example- 15122.69 = (1.3*2*4.09)/((12^2)-(5^2)).
How to calculate Coefficient of Aquifer Permeability considering Discharge per Unit Width of Aquifer?
With Discharge (Q), Length between Upstream and Downstream (Lstream), Piezometric Head at Upstream End (ho) & Piezometric Head at Downstream End (h1) we can find Coefficient of Aquifer Permeability considering Discharge per Unit Width of Aquifer using the formula - Coefficient of Permeability = (Discharge*2*Length between Upstream and Downstream)/((Piezometric Head at Upstream End^2)-(Piezometric Head at Downstream End^2)).
What are the other ways to Calculate Coefficient of Permeability?
Here are the different ways to Calculate Coefficient of Permeability-
  • Coefficient of Permeability=(Natural Recharge*Length between Tile Drain^2)/(2*Maximum Height of Water Table)^2OpenImg
  • Coefficient of Permeability=((Natural Recharge/Water Table Profile^2)*(Length between Tile Drain-Flow in 'x' Direction)*Flow in 'x' Direction)OpenImg
Can the Coefficient of Aquifer Permeability considering Discharge per Unit Width of Aquifer be negative?
No, the Coefficient of Aquifer Permeability considering Discharge per Unit Width of Aquifer, measured in Speed cannot be negative.
Which unit is used to measure Coefficient of Aquifer Permeability considering Discharge per Unit Width of Aquifer?
Coefficient of Aquifer Permeability considering Discharge per Unit Width of Aquifer is usually measured using the Centimeter per Second[cm/s] for Speed. Meter per Second[cm/s], Meter per Minute[cm/s], Meter per Hour[cm/s] are the few other units in which Coefficient of Aquifer Permeability considering Discharge per Unit Width of Aquifer can be measured.
Copied!