Clear Distance from Flanges for Concentrated Load with Stiffeners Formula

Fx Copy
LaTeX Copy
Clear Distance between Flanges refers to the distance between the two endpoints of the flange. That is the height of the web including fillets. Check FAQs
h=(6800tw3R)(1+(0.4rwf3))
h - Clear Distance between Flanges?tw - Web Thickness?R - Concentrated Load of Reaction?rwf - Slenderness of Web and Flange?

Clear Distance from Flanges for Concentrated Load with Stiffeners Example

With values
With units
Only example

Here is how the Clear Distance from Flanges for Concentrated Load with Stiffeners equation looks like with Values.

Here is how the Clear Distance from Flanges for Concentrated Load with Stiffeners equation looks like with Units.

Here is how the Clear Distance from Flanges for Concentrated Load with Stiffeners equation looks like.

121.5319Edit=(6800100Edit3235Edit)(1+(0.42Edit3))
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Design of Steel Structures » fx Clear Distance from Flanges for Concentrated Load with Stiffeners

Clear Distance from Flanges for Concentrated Load with Stiffeners Solution

Follow our step by step solution on how to calculate Clear Distance from Flanges for Concentrated Load with Stiffeners?

FIRST Step Consider the formula
h=(6800tw3R)(1+(0.4rwf3))
Next Step Substitute values of Variables
h=(6800100mm3235kN)(1+(0.423))
Next Step Convert Units
h=(68000.1m3235kN)(1+(0.423))
Next Step Prepare to Evaluate
h=(68000.13235)(1+(0.423))
Next Step Evaluate
h=0.121531914893617m
Next Step Convert to Output's Unit
h=121.531914893617mm
LAST Step Rounding Answer
h=121.5319mm

Clear Distance from Flanges for Concentrated Load with Stiffeners Formula Elements

Variables
Clear Distance between Flanges
Clear Distance between Flanges refers to the distance between the two endpoints of the flange. That is the height of the web including fillets.
Symbol: h
Measurement: LengthUnit: mm
Note: Value should be greater than 0.
Web Thickness
Web Thickness is the thickness of the web section in the member of I section.
Symbol: tw
Measurement: LengthUnit: mm
Note: Value should be greater than 0.
Concentrated Load of Reaction
Concentrated Load of Reaction is the reaction force that is assumed to act at a single point on the structure.
Symbol: R
Measurement: ForceUnit: kN
Note: Value should be greater than 0.
Slenderness of Web and Flange
Slenderness of Web and Flange of a structural element is a measure of its susceptibility to buckling under compressive stress.
Symbol: rwf
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.

Other formulas in Webs under Concentrated Loads category

​Go Stress when Concentrated Load is Applied Close to Beam End
fa=Rtw(N+2.5k)
​Go Stress for Concentrated Load Applied at Distance Larger than Depth of Beam
fa=Rtw(N+5k)
​Go Length of Bearing when Load applied at Distance Larger than Depth of Beam
N=(Rfatw)-5k
​Go Web Thickness for Given Stress
tw=Rfa(N+5k)

How to Evaluate Clear Distance from Flanges for Concentrated Load with Stiffeners?

Clear Distance from Flanges for Concentrated Load with Stiffeners evaluator uses Clear Distance between Flanges = ((6800*Web Thickness^3)/Concentrated Load of Reaction)*(1+(0.4*Slenderness of Web and Flange^3)) to evaluate the Clear Distance between Flanges, The Clear Distance from Flanges for Concentrated Load with Stiffeners formula is defined as the distance between the top and bottom flange when the relative slenderness of the web and flange is 2.3. Clear Distance between Flanges is denoted by h symbol.

How to evaluate Clear Distance from Flanges for Concentrated Load with Stiffeners using this online evaluator? To use this online evaluator for Clear Distance from Flanges for Concentrated Load with Stiffeners, enter Web Thickness (tw), Concentrated Load of Reaction (R) & Slenderness of Web and Flange (rwf) and hit the calculate button.

FAQs on Clear Distance from Flanges for Concentrated Load with Stiffeners

What is the formula to find Clear Distance from Flanges for Concentrated Load with Stiffeners?
The formula of Clear Distance from Flanges for Concentrated Load with Stiffeners is expressed as Clear Distance between Flanges = ((6800*Web Thickness^3)/Concentrated Load of Reaction)*(1+(0.4*Slenderness of Web and Flange^3)). Here is an example- 121531.9 = ((6800*0.1^3)/235000)*(1+(0.4*2^3)).
How to calculate Clear Distance from Flanges for Concentrated Load with Stiffeners?
With Web Thickness (tw), Concentrated Load of Reaction (R) & Slenderness of Web and Flange (rwf) we can find Clear Distance from Flanges for Concentrated Load with Stiffeners using the formula - Clear Distance between Flanges = ((6800*Web Thickness^3)/Concentrated Load of Reaction)*(1+(0.4*Slenderness of Web and Flange^3)).
Can the Clear Distance from Flanges for Concentrated Load with Stiffeners be negative?
No, the Clear Distance from Flanges for Concentrated Load with Stiffeners, measured in Length cannot be negative.
Which unit is used to measure Clear Distance from Flanges for Concentrated Load with Stiffeners?
Clear Distance from Flanges for Concentrated Load with Stiffeners is usually measured using the Millimeter[mm] for Length. Meter[mm], Kilometer[mm], Decimeter[mm] are the few other units in which Clear Distance from Flanges for Concentrated Load with Stiffeners can be measured.
Copied!