Clausius Parameter b given Reduced and Actual Parameters Formula

Fx Copy
LaTeX Copy
Clausius Parameter b given RP is an empirical parameter characteristic to equation obtained from Clausius model of real gas. Check FAQs
bRP=(VrealVr)-([R](TrgTr)4(pPr))
bRP - Clausius Parameter b given RP?Vreal - Volume of Real Gas?Vr - Reduced Volume?Trg - Temperature of Real Gas?Tr - Reduced Temperature?p - Pressure?Pr - Reduced Pressure?[R] - Universal gas constant?

Clausius Parameter b given Reduced and Actual Parameters Example

With values
With units
Only example

Here is how the Clausius Parameter b given Reduced and Actual Parameters equation looks like with Values.

Here is how the Clausius Parameter b given Reduced and Actual Parameters equation looks like with Units.

Here is how the Clausius Parameter b given Reduced and Actual Parameters equation looks like.

2.2534Edit=(22Edit9.5Edit)-(8.3145(300Edit10Edit)4(800Edit0.8Edit))
You are here -
HomeIcon Home » Category Chemistry » Category Kinetic Theory of Gases » Category Real Gas » fx Clausius Parameter b given Reduced and Actual Parameters

Clausius Parameter b given Reduced and Actual Parameters Solution

Follow our step by step solution on how to calculate Clausius Parameter b given Reduced and Actual Parameters?

FIRST Step Consider the formula
bRP=(VrealVr)-([R](TrgTr)4(pPr))
Next Step Substitute values of Variables
bRP=(22L9.5L)-([R](300K10)4(800Pa0.8))
Next Step Substitute values of Constants
bRP=(22L9.5L)-(8.3145(300K10)4(800Pa0.8))
Next Step Convert Units
bRP=(0.0220.0095)-(8.3145(300K10)4(800Pa0.8))
Next Step Prepare to Evaluate
bRP=(0.0220.0095)-(8.3145(30010)4(8000.8))
Next Step Evaluate
bRP=2.25343100404806
LAST Step Rounding Answer
bRP=2.2534

Clausius Parameter b given Reduced and Actual Parameters Formula Elements

Variables
Constants
Clausius Parameter b given RP
Clausius Parameter b given RP is an empirical parameter characteristic to equation obtained from Clausius model of real gas.
Symbol: bRP
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Volume of Real Gas
Volume of Real Gas is the space occupied by that real gas at standard temperature and pressure.
Symbol: Vreal
Measurement: VolumeUnit: L
Note: Value should be greater than 0.
Reduced Volume
Reduced Volume of a fluid is computed from the ideal gas law as the ratio of its actual volume to critical volume.
Symbol: Vr
Measurement: VolumeUnit: L
Note: Value can be positive or negative.
Temperature of Real Gas
Temperature of Real Gas is the degree or intensity of heat present in a substance or object.
Symbol: Trg
Measurement: TemperatureUnit: K
Note: Value can be positive or negative.
Reduced Temperature
Reduced Temperature is the ratio of the actual temperature of the fluid to its critical temperature. It is dimensionless.
Symbol: Tr
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Pressure
Pressure is the force applied perpendicular to the surface of an object per unit area over which that force is distributed.
Symbol: p
Measurement: PressureUnit: Pa
Note: Value can be positive or negative.
Reduced Pressure
Reduced Pressure is the ratio of the actual pressure of the fluid to its critical pressure. It is dimensionless.
Symbol: Pr
Measurement: NAUnit: Unitless
Note: Value should be between 0 to 1.
Universal gas constant
Universal gas constant is a fundamental physical constant that appears in the ideal gas law, relating the pressure, volume, and temperature of an ideal gas.
Symbol: [R]
Value: 8.31446261815324

Other formulas in Clausius Parameter category

​Go Actual Pressure of Real Gas given Clausius Parameter a, Reduced and Critical Parameters
Pa=(27([R]2)(T'c3)64a)Pr
​Go Actual Pressure of Real Gas given Clausius Parameter b, Reduced and Actual Parameters
Pb=([R](TrgTr)4((VrealVr)-b'))Pr

How to Evaluate Clausius Parameter b given Reduced and Actual Parameters?

Clausius Parameter b given Reduced and Actual Parameters evaluator uses Clausius Parameter b given RP = (Volume of Real Gas/Reduced Volume)-(([R]*(Temperature of Real Gas/Reduced Temperature))/(4*(Pressure/Reduced Pressure))) to evaluate the Clausius Parameter b given RP, The Clausius parameter b given reduced and actual parameters formula is defined as an empirical parameter characteristic to equation obtained from Clausius model of real gas. Clausius Parameter b given RP is denoted by bRP symbol.

How to evaluate Clausius Parameter b given Reduced and Actual Parameters using this online evaluator? To use this online evaluator for Clausius Parameter b given Reduced and Actual Parameters, enter Volume of Real Gas (Vreal), Reduced Volume (Vr), Temperature of Real Gas (Trg), Reduced Temperature (Tr), Pressure (p) & Reduced Pressure (Pr) and hit the calculate button.

FAQs on Clausius Parameter b given Reduced and Actual Parameters

What is the formula to find Clausius Parameter b given Reduced and Actual Parameters?
The formula of Clausius Parameter b given Reduced and Actual Parameters is expressed as Clausius Parameter b given RP = (Volume of Real Gas/Reduced Volume)-(([R]*(Temperature of Real Gas/Reduced Temperature))/(4*(Pressure/Reduced Pressure))). Here is an example- 2.298121 = (0.022/0.0095)-(([R]*(300/10))/(4*(800/0.8))).
How to calculate Clausius Parameter b given Reduced and Actual Parameters?
With Volume of Real Gas (Vreal), Reduced Volume (Vr), Temperature of Real Gas (Trg), Reduced Temperature (Tr), Pressure (p) & Reduced Pressure (Pr) we can find Clausius Parameter b given Reduced and Actual Parameters using the formula - Clausius Parameter b given RP = (Volume of Real Gas/Reduced Volume)-(([R]*(Temperature of Real Gas/Reduced Temperature))/(4*(Pressure/Reduced Pressure))). This formula also uses Universal gas constant .
Copied!