Circuit Turn off Time Class C Commutation Formula

Fx Copy
LaTeX Copy
Circuit turn off time Class C commutation is the time required by the thyristor circuit to turn off for class C commutation. Check FAQs
tC(off)=RstbCcomln(2)
tC(off) - Circuit Turn Off Time Class C Commutation?Rstb - Stablizing Resistance?Ccom - Thyristor Commutation Capacitance?

Circuit Turn off Time Class C Commutation Example

With values
With units
Only example

Here is how the Circuit Turn off Time Class C Commutation equation looks like with Values.

Here is how the Circuit Turn off Time Class C Commutation equation looks like with Units.

Here is how the Circuit Turn off Time Class C Commutation equation looks like.

0.6654Edit=32Edit0.03Editln(2)
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power Electronics » fx Circuit Turn off Time Class C Commutation

Circuit Turn off Time Class C Commutation Solution

Follow our step by step solution on how to calculate Circuit Turn off Time Class C Commutation?

FIRST Step Consider the formula
tC(off)=RstbCcomln(2)
Next Step Substitute values of Variables
tC(off)=32Ω0.03Fln(2)
Next Step Prepare to Evaluate
tC(off)=320.03ln(2)
Next Step Evaluate
tC(off)=0.665421293337547s
LAST Step Rounding Answer
tC(off)=0.6654s

Circuit Turn off Time Class C Commutation Formula Elements

Variables
Functions
Circuit Turn Off Time Class C Commutation
Circuit turn off time Class C commutation is the time required by the thyristor circuit to turn off for class C commutation.
Symbol: tC(off)
Measurement: TimeUnit: s
Note: Value should be greater than 0.
Stablizing Resistance
Stablizing Resistance is defined as the opposition faced by the flow of current through a thyristor based circuit which is used to stablize.
Symbol: Rstb
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.
Thyristor Commutation Capacitance
Thyristor Commutation Capacitance refers to the capacitance present in a thyristor device that affects the commutation process.
Symbol: Ccom
Measurement: CapacitanceUnit: F
Note: Value should be greater than 0.
ln
The natural logarithm, also known as the logarithm to the base e, is the inverse function of the natural exponential function.
Syntax: ln(Number)

Other formulas in SCR or Thyristor Commutation category

​Go Derating Factor of Series Connected Thyristor String
DRF=1-VstringVssn
​Go Leakage Current of Collector-Base Junction
ICBO=IC-αIC
​Go Power Dissipated by Heat in SCR
Pdis=Tjunc-Tambθ
​Go Thermal Resistance of SCR
θ=Tjunc-TambPdis

How to Evaluate Circuit Turn off Time Class C Commutation?

Circuit Turn off Time Class C Commutation evaluator uses Circuit Turn Off Time Class C Commutation = Stablizing Resistance*Thyristor Commutation Capacitance*ln(2) to evaluate the Circuit Turn Off Time Class C Commutation, The Circuit turn off time Class C commutation formula is defined as the time required by the thyristor circuit to turn off for class C commutation. Circuit Turn Off Time Class C Commutation is denoted by tC(off) symbol.

How to evaluate Circuit Turn off Time Class C Commutation using this online evaluator? To use this online evaluator for Circuit Turn off Time Class C Commutation, enter Stablizing Resistance (Rstb) & Thyristor Commutation Capacitance (Ccom) and hit the calculate button.

FAQs on Circuit Turn off Time Class C Commutation

What is the formula to find Circuit Turn off Time Class C Commutation?
The formula of Circuit Turn off Time Class C Commutation is expressed as Circuit Turn Off Time Class C Commutation = Stablizing Resistance*Thyristor Commutation Capacitance*ln(2). Here is an example- 0.665421 = 32*0.03*ln(2).
How to calculate Circuit Turn off Time Class C Commutation?
With Stablizing Resistance (Rstb) & Thyristor Commutation Capacitance (Ccom) we can find Circuit Turn off Time Class C Commutation using the formula - Circuit Turn Off Time Class C Commutation = Stablizing Resistance*Thyristor Commutation Capacitance*ln(2). This formula also uses Natural Logarithm (ln) function(s).
Can the Circuit Turn off Time Class C Commutation be negative?
No, the Circuit Turn off Time Class C Commutation, measured in Time cannot be negative.
Which unit is used to measure Circuit Turn off Time Class C Commutation?
Circuit Turn off Time Class C Commutation is usually measured using the Second[s] for Time. Millisecond[s], Microsecond[s], Nanosecond[s] are the few other units in which Circuit Turn off Time Class C Commutation can be measured.
Copied!