Fx Copy
LaTeX Copy
The characteristic impedance of a uniform transmission line is the ratio of the amplitudes of voltage and current of a single wave propagating along the line during transient condition. Check FAQs
Z0=Il1-ρvρv+1
Z0 - Characteristic Impedance?Il - Load Impedance?ρv - Reflection Coefficient of Voltage?

Characteristic Impedance using Reflected Coefficient of Voltage Example

With values
With units
Only example

Here is how the Characteristic Impedance using Reflected Coefficient of Voltage equation looks like with Values.

Here is how the Characteristic Impedance using Reflected Coefficient of Voltage equation looks like with Units.

Here is how the Characteristic Impedance using Reflected Coefficient of Voltage equation looks like.

-5.7067Edit=8.56Edit1-5Edit5Edit+1
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Characteristic Impedance using Reflected Coefficient of Voltage

Characteristic Impedance using Reflected Coefficient of Voltage Solution

Follow our step by step solution on how to calculate Characteristic Impedance using Reflected Coefficient of Voltage?

FIRST Step Consider the formula
Z0=Il1-ρvρv+1
Next Step Substitute values of Variables
Z0=8.56Ω1-55+1
Next Step Prepare to Evaluate
Z0=8.561-55+1
Next Step Evaluate
Z0=-5.70666666666667Ω
LAST Step Rounding Answer
Z0=-5.7067Ω

Characteristic Impedance using Reflected Coefficient of Voltage Formula Elements

Variables
Characteristic Impedance
The characteristic impedance of a uniform transmission line is the ratio of the amplitudes of voltage and current of a single wave propagating along the line during transient condition.
Symbol: Z0
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.
Load Impedance
The load impedance is defined as the impedance of the load of the Transmission line during transient.
Symbol: Il
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.
Reflection Coefficient of Voltage
Reflection Coefficient Of Voltage is defined as the ratio of the reflected voltage to the incident voltage of the Transmission line during any transient condition.
Symbol: ρv
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.

Other Formulas to find Characteristic Impedance

​Go Characteristic Impedance (Line SC)
Z0=ViIi
​Go Characteristic Impedance using Transmitted Current
Z0=Il2Ii-ItIt
​Go Characteristic Impedance using Reflected Coefficient of Current
Z0=Ilρi-11-ρi
​Go Characteristic Impedance using Transmitted Coefficient of Voltage
Z0=Il2-τvτv

Other formulas in Transient category

​Go Incident Voltage using Transmitted Voltage (Load OC)
Vi=Vt2
​Go Load Impedance using Reflected Coefficient of Current
Il=Z01-ρiρi-1
​Go Load Impedance using Reflected Coefficient of Voltage
Il=Z0ρv+11-ρv
​Go Reflection Coefficient for Voltage
ρv=ErVi

How to Evaluate Characteristic Impedance using Reflected Coefficient of Voltage?

Characteristic Impedance using Reflected Coefficient of Voltage evaluator uses Characteristic Impedance = Load Impedance*(1-Reflection Coefficient of Voltage)/(Reflection Coefficient of Voltage+1) to evaluate the Characteristic Impedance, The Characteristic Impedance using Reflected Coefficient of Voltage formula is defined as a uniform transmission line is the ratio of the amplitudes of voltage and current of a single wave propagating along the line. Characteristic Impedance is denoted by Z0 symbol.

How to evaluate Characteristic Impedance using Reflected Coefficient of Voltage using this online evaluator? To use this online evaluator for Characteristic Impedance using Reflected Coefficient of Voltage, enter Load Impedance (Il) & Reflection Coefficient of Voltage v) and hit the calculate button.

FAQs on Characteristic Impedance using Reflected Coefficient of Voltage

What is the formula to find Characteristic Impedance using Reflected Coefficient of Voltage?
The formula of Characteristic Impedance using Reflected Coefficient of Voltage is expressed as Characteristic Impedance = Load Impedance*(1-Reflection Coefficient of Voltage)/(Reflection Coefficient of Voltage+1). Here is an example- -5.706667 = 8.56*(1-5)/(5+1).
How to calculate Characteristic Impedance using Reflected Coefficient of Voltage?
With Load Impedance (Il) & Reflection Coefficient of Voltage v) we can find Characteristic Impedance using Reflected Coefficient of Voltage using the formula - Characteristic Impedance = Load Impedance*(1-Reflection Coefficient of Voltage)/(Reflection Coefficient of Voltage+1).
What are the other ways to Calculate Characteristic Impedance?
Here are the different ways to Calculate Characteristic Impedance-
  • Characteristic Impedance=Incident Voltage/Incident CurrentOpenImg
  • Characteristic Impedance=Load Impedance*(2*Incident Current-Transmitted Current)/Transmitted CurrentOpenImg
  • Characteristic Impedance=Load Impedance*(Reflection Coefficient of Current-1)/(1-Reflection Coefficient of Current)OpenImg
Can the Characteristic Impedance using Reflected Coefficient of Voltage be negative?
Yes, the Characteristic Impedance using Reflected Coefficient of Voltage, measured in Electric Resistance can be negative.
Which unit is used to measure Characteristic Impedance using Reflected Coefficient of Voltage?
Characteristic Impedance using Reflected Coefficient of Voltage is usually measured using the Ohm[Ω] for Electric Resistance. Megohm[Ω], Microhm[Ω], Volt per Ampere[Ω] are the few other units in which Characteristic Impedance using Reflected Coefficient of Voltage can be measured.
Copied!