Cease to Flow Depth given Depth at Gauging Station Formula

Fx Copy
LaTeX Copy
Cease-to-Flow Depth when hydraulics of a downstream control and a gauging station are considered. Check FAQs
hcsf=hG-Hc(Q)-Q22
hcsf - Cease-to-Flow Depth?hG - Depth at Gauging Station?Hc - Head at Control?Q - Discharge?Q2 - Terms of Order?

Cease to Flow Depth given Depth at Gauging Station Example

With values
With units
Only example

Here is how the Cease to Flow Depth given Depth at Gauging Station equation looks like with Values.

Here is how the Cease to Flow Depth given Depth at Gauging Station equation looks like with Units.

Here is how the Cease to Flow Depth given Depth at Gauging Station equation looks like.

0.1Edit=6.01Edit-0.05Edit(3Edit)-2.4Edit2
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Engineering Hydrology » fx Cease to Flow Depth given Depth at Gauging Station

Cease to Flow Depth given Depth at Gauging Station Solution

Follow our step by step solution on how to calculate Cease to Flow Depth given Depth at Gauging Station?

FIRST Step Consider the formula
hcsf=hG-Hc(Q)-Q22
Next Step Substitute values of Variables
hcsf=6.01m-0.05m(3m³/s)-2.42
Next Step Prepare to Evaluate
hcsf=6.01-0.05(3)-2.42
Next Step Evaluate
hcsf=0.0999999999999996m
LAST Step Rounding Answer
hcsf=0.1m

Cease to Flow Depth given Depth at Gauging Station Formula Elements

Variables
Cease-to-Flow Depth
Cease-to-Flow Depth when hydraulics of a downstream control and a gauging station are considered.
Symbol: hcsf
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Depth at Gauging Station
Depth at Gauging Station where the hydraulics of a downstream control and a gauging station are considered.
Symbol: hG
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Head at Control
Head at Control shown as a function of discharge Q.
Symbol: Hc
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Discharge
The Discharge refers to the volumetric flow rate of water that is transported through a given cross-sectional area. It includes any suspended solids, dissolved chemicals, or biologic material.
Symbol: Q
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Terms of Order
Terms of Order give the head loss between the gauging station and the control.
Symbol: Q2
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.

Other formulas in Low Flow category

​Go Depth at Gauging Station
hG=hcsf+Hc(Q)+Q22
​Go Head at Control given Depth at Gauging Station
Hc=hG-hcsf-Q22Q
​Go Discharge given Depth at Gauging Station
Q=hG-hcsf-Q22Hc

How to Evaluate Cease to Flow Depth given Depth at Gauging Station?

Cease to Flow Depth given Depth at Gauging Station evaluator uses Cease-to-Flow Depth = Depth at Gauging Station-Head at Control*(Discharge)-Terms of Order^2 to evaluate the Cease-to-Flow Depth, The Cease to Flow Depth given Depth at Gauging Station formula is defined as the parameters of low flow when the hydraulics of a downstream control and a gauging station are considered. Cease-to-Flow Depth is denoted by hcsf symbol.

How to evaluate Cease to Flow Depth given Depth at Gauging Station using this online evaluator? To use this online evaluator for Cease to Flow Depth given Depth at Gauging Station, enter Depth at Gauging Station (hG), Head at Control (Hc), Discharge (Q) & Terms of Order (Q2) and hit the calculate button.

FAQs on Cease to Flow Depth given Depth at Gauging Station

What is the formula to find Cease to Flow Depth given Depth at Gauging Station?
The formula of Cease to Flow Depth given Depth at Gauging Station is expressed as Cease-to-Flow Depth = Depth at Gauging Station-Head at Control*(Discharge)-Terms of Order^2. Here is an example- 0.1 = 6.01-0.05*(3)-2.4^2.
How to calculate Cease to Flow Depth given Depth at Gauging Station?
With Depth at Gauging Station (hG), Head at Control (Hc), Discharge (Q) & Terms of Order (Q2) we can find Cease to Flow Depth given Depth at Gauging Station using the formula - Cease-to-Flow Depth = Depth at Gauging Station-Head at Control*(Discharge)-Terms of Order^2.
Can the Cease to Flow Depth given Depth at Gauging Station be negative?
No, the Cease to Flow Depth given Depth at Gauging Station, measured in Length cannot be negative.
Which unit is used to measure Cease to Flow Depth given Depth at Gauging Station?
Cease to Flow Depth given Depth at Gauging Station is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Cease to Flow Depth given Depth at Gauging Station can be measured.
Copied!