Catchment Area when Recharge from Rainfall is Considered Formula

Fx Copy
LaTeX Copy
The Area of Computation for Recharge refers to the catchment area where the amount of water infiltrating the ground and replenishing aquifers is calculated, crucial for managing groundwater resources. Check FAQs
Acr=RrfmfPnm
Acr - Area of Computation for Recharge?Rrfm - Recharge from Rainfall in Monsoon Season?f - Rainfall Infiltration Factor?Pnm - Normal Rainfall in Monsoon Season?

Catchment Area when Recharge from Rainfall is Considered Example

With values
With units
Only example

Here is how the Catchment Area when Recharge from Rainfall is Considered equation looks like with Values.

Here is how the Catchment Area when Recharge from Rainfall is Considered equation looks like with Units.

Here is how the Catchment Area when Recharge from Rainfall is Considered equation looks like.

13.2576Edit=7Edit22Edit0.024Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Engineering Hydrology » fx Catchment Area when Recharge from Rainfall is Considered

Catchment Area when Recharge from Rainfall is Considered Solution

Follow our step by step solution on how to calculate Catchment Area when Recharge from Rainfall is Considered?

FIRST Step Consider the formula
Acr=RrfmfPnm
Next Step Substitute values of Variables
Acr=7m³/s220.024m
Next Step Prepare to Evaluate
Acr=7220.024
Next Step Evaluate
Acr=13.2575757575758
LAST Step Rounding Answer
Acr=13.2576

Catchment Area when Recharge from Rainfall is Considered Formula Elements

Variables
Area of Computation for Recharge
The Area of Computation for Recharge refers to the catchment area where the amount of water infiltrating the ground and replenishing aquifers is calculated, crucial for managing groundwater resources.
Symbol: Acr
Measurement: AreaUnit:
Note: Value can be positive or negative.
Recharge from Rainfall in Monsoon Season
Recharge from Rainfall in Monsoon Season is the infiltration and percolation of rainwater into subsurface aquifers, primarily occurring during the monsoon period when rainfall is significantly higher.
Symbol: Rrfm
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value can be positive or negative.
Rainfall Infiltration Factor
The Rainfall Infiltration Factor refers to the measure of the rate at which water from rainfall penetrates into the soil, a critical parameter, influencing design and management of water resources.
Symbol: f
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Normal Rainfall in Monsoon Season
The Normal Rainfall in Monsoon Season refers to the statistical average of rainfall measured over a specified period, typically 30 years, during the monsoon months in a given region.
Symbol: Pnm
Measurement: LengthUnit: m
Note: Value can be positive or negative.

Other formulas in Rainfall Infiltration Method category

​Go Recharge from Rainfall in Monsoon Season by Rainfall Infiltration Method
Rrfm=fAcrPnm
​Go Rainfall Infiltration Factor when Recharge from Rainfall is Considered
f=RrfmAcrPnm
​Go Normal Rainfall in Monsoon Season
Pnm=RrfmfAcr

How to Evaluate Catchment Area when Recharge from Rainfall is Considered?

Catchment Area when Recharge from Rainfall is Considered evaluator uses Area of Computation for Recharge = Recharge from Rainfall in Monsoon Season/(Rainfall Infiltration Factor*Normal Rainfall in Monsoon Season) to evaluate the Area of Computation for Recharge, The Catchment Area when Recharge from Rainfall is Considered formula is defined as the region from which all precipitation flows to a common outlet, such as a river, lake, or ocean. When considering recharge from rainfall, the catchment area includes not only the surface runoff but also the portion of rainfall that infiltrates the ground and recharges the groundwater. This comprehensive approach considers both surface and subsurface hydrological processes. Area of Computation for Recharge is denoted by Acr symbol.

How to evaluate Catchment Area when Recharge from Rainfall is Considered using this online evaluator? To use this online evaluator for Catchment Area when Recharge from Rainfall is Considered, enter Recharge from Rainfall in Monsoon Season (Rrfm), Rainfall Infiltration Factor (f) & Normal Rainfall in Monsoon Season (Pnm) and hit the calculate button.

FAQs on Catchment Area when Recharge from Rainfall is Considered

What is the formula to find Catchment Area when Recharge from Rainfall is Considered?
The formula of Catchment Area when Recharge from Rainfall is Considered is expressed as Area of Computation for Recharge = Recharge from Rainfall in Monsoon Season/(Rainfall Infiltration Factor*Normal Rainfall in Monsoon Season). Here is an example- 13.25758 = 7/(22*0.024).
How to calculate Catchment Area when Recharge from Rainfall is Considered?
With Recharge from Rainfall in Monsoon Season (Rrfm), Rainfall Infiltration Factor (f) & Normal Rainfall in Monsoon Season (Pnm) we can find Catchment Area when Recharge from Rainfall is Considered using the formula - Area of Computation for Recharge = Recharge from Rainfall in Monsoon Season/(Rainfall Infiltration Factor*Normal Rainfall in Monsoon Season).
Can the Catchment Area when Recharge from Rainfall is Considered be negative?
Yes, the Catchment Area when Recharge from Rainfall is Considered, measured in Area can be negative.
Which unit is used to measure Catchment Area when Recharge from Rainfall is Considered?
Catchment Area when Recharge from Rainfall is Considered is usually measured using the Square Meter[m²] for Area. Square Kilometer[m²], Square Centimeter[m²], Square Millimeter[m²] are the few other units in which Catchment Area when Recharge from Rainfall is Considered can be measured.
Copied!