Capacity Factor given Partition Coefficient and Volume of Mobile and Stationary Phase Formula

Fx Copy
LaTeX Copy
The Capacity factor given partition Coeff is directly proportional to the retention factor. The longer a component is retained by the column, the greater is the capacity factor. Check FAQs
kc'1=K(VsVmobile phase)
kc'1 - Capacity Factor given partition Coeff?K - Partition Coefficient?Vs - Volume of Stationary Phase?Vmobile phase - Volume of Mobile Phase?

Capacity Factor given Partition Coefficient and Volume of Mobile and Stationary Phase Example

With values
With units
Only example

Here is how the Capacity Factor given Partition Coefficient and Volume of Mobile and Stationary Phase equation looks like with Values.

Here is how the Capacity Factor given Partition Coefficient and Volume of Mobile and Stationary Phase equation looks like with Units.

Here is how the Capacity Factor given Partition Coefficient and Volume of Mobile and Stationary Phase equation looks like.

56Edit=40Edit(7Edit5Edit)
You are here -
HomeIcon Home » Category Chemistry » Category Analytical chemistry » Category Method of Separation Technique » fx Capacity Factor given Partition Coefficient and Volume of Mobile and Stationary Phase

Capacity Factor given Partition Coefficient and Volume of Mobile and Stationary Phase Solution

Follow our step by step solution on how to calculate Capacity Factor given Partition Coefficient and Volume of Mobile and Stationary Phase?

FIRST Step Consider the formula
kc'1=K(VsVmobile phase)
Next Step Substitute values of Variables
kc'1=40(7L5L)
Next Step Convert Units
kc'1=40(0.0070.005)
Next Step Prepare to Evaluate
kc'1=40(0.0070.005)
LAST Step Evaluate
kc'1=56

Capacity Factor given Partition Coefficient and Volume of Mobile and Stationary Phase Formula Elements

Variables
Capacity Factor given partition Coeff
The Capacity factor given partition Coeff is directly proportional to the retention factor. The longer a component is retained by the column, the greater is the capacity factor.
Symbol: kc'1
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Partition Coefficient
The Partition Coefficient is defined as the ratio of the equilibrium concentrations of a dissolved substance in a two-phase system consisting of two largely immiscible solvents.
Symbol: K
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Volume of Stationary Phase
The Volume of Stationary Phase is the amount of motionless part of the chromatography column.
Symbol: Vs
Measurement: VolumeUnit: L
Note: Value can be positive or negative.
Volume of Mobile Phase
The Volume of Mobile Phase is the amount of the solvent that runs through the chromatography column.
Symbol: Vmobile phase
Measurement: VolumeUnit: L
Note: Value can be positive or negative.

Other formulas in Capacity factor category

​Go Height of Column given Number of Theoretical Plates
HTP=(LN)
​Go Number of Theoretical Plates given Length and Height of Column
NLandH=(LH)
​Go Number of Theoretical Plates given Length of Column and Standard Deviation
NLandSD=(L)2(σ)2
​Go Number of Theoretical Plates given Length of Column and Width of Peak
NLandW=16((L)2)(w)2

How to Evaluate Capacity Factor given Partition Coefficient and Volume of Mobile and Stationary Phase?

Capacity Factor given Partition Coefficient and Volume of Mobile and Stationary Phase evaluator uses Capacity Factor given partition Coeff = Partition Coefficient*(Volume of Stationary Phase/Volume of Mobile Phase) to evaluate the Capacity Factor given partition Coeff, The Capacity factor given partition coefficient and volume of mobile and stationary phase formula is defined as the product of partition coefficient and ratio volume of stationary phase to the mobile phase. Capacity Factor given partition Coeff is denoted by kc'1 symbol.

How to evaluate Capacity Factor given Partition Coefficient and Volume of Mobile and Stationary Phase using this online evaluator? To use this online evaluator for Capacity Factor given Partition Coefficient and Volume of Mobile and Stationary Phase, enter Partition Coefficient (K), Volume of Stationary Phase (Vs) & Volume of Mobile Phase (Vmobile phase) and hit the calculate button.

FAQs on Capacity Factor given Partition Coefficient and Volume of Mobile and Stationary Phase

What is the formula to find Capacity Factor given Partition Coefficient and Volume of Mobile and Stationary Phase?
The formula of Capacity Factor given Partition Coefficient and Volume of Mobile and Stationary Phase is expressed as Capacity Factor given partition Coeff = Partition Coefficient*(Volume of Stationary Phase/Volume of Mobile Phase). Here is an example- 56 = 40*(0.007/0.005).
How to calculate Capacity Factor given Partition Coefficient and Volume of Mobile and Stationary Phase?
With Partition Coefficient (K), Volume of Stationary Phase (Vs) & Volume of Mobile Phase (Vmobile phase) we can find Capacity Factor given Partition Coefficient and Volume of Mobile and Stationary Phase using the formula - Capacity Factor given partition Coeff = Partition Coefficient*(Volume of Stationary Phase/Volume of Mobile Phase).
Copied!