Capacitance with No Liquid Formula

Fx Copy
LaTeX Copy
No Fluid Capacitance is non-liquid submerged capacitance. Check FAQs
Ca=CR(DLμ)+R
Ca - No Fluid Capacitance?C - Capacitance?R - Plate Height?DL - Liquid Level between Plates?μ - Dielectric Constant?

Capacitance with No Liquid Example

With values
With units
Only example

Here is how the Capacitance with No Liquid equation looks like with Values.

Here is how the Capacitance with No Liquid equation looks like with Units.

Here is how the Capacitance with No Liquid equation looks like.

4.5909Edit=10.1Edit1.05Edit(0.021Edit60Edit)+1.05Edit
You are here -
HomeIcon Home » Category Engineering » Category Electronics and Instrumentation » Category Measurement of Physical Parameters » fx Capacitance with No Liquid

Capacitance with No Liquid Solution

Follow our step by step solution on how to calculate Capacitance with No Liquid?

FIRST Step Consider the formula
Ca=CR(DLμ)+R
Next Step Substitute values of Variables
Ca=10.1F1.05m(0.021m60)+1.05m
Next Step Prepare to Evaluate
Ca=10.11.05(0.02160)+1.05
Next Step Evaluate
Ca=4.59090909090909F
LAST Step Rounding Answer
Ca=4.5909F

Capacitance with No Liquid Formula Elements

Variables
No Fluid Capacitance
No Fluid Capacitance is non-liquid submerged capacitance.
Symbol: Ca
Measurement: CapacitanceUnit: F
Note: Value should be greater than 0.
Capacitance
Capacitance is the ratio of the amount of electric charge stored on a conductor to a difference in electric potential.
Symbol: C
Measurement: CapacitanceUnit: F
Note: Value should be greater than 0.
Plate Height
Plate Height refers to the distance between the top and bottom surfaces of plates used in devices like capacitance level sensors to gauge fluid levels.
Symbol: R
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Liquid Level between Plates
Liquid Level between Plates refers to the distance or thickness of a liquid layer present between two parallel plates.
Symbol: DL
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Dielectric Constant
Dielectric Constant is a measure of a material's ability to store electrical energy in an electric field, influencing its capacitance and determining its electrical properties.
Symbol: μ
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.

Other formulas in Level Measurement category

​Go Depth of Fluid
d=ΔPγ
​Go Buoyancy
Fb=DimAγ
​Go Cross-Sectional Area of Object
A=FbDimγ
​Go Immersed Depth
Dim=FbAγ

How to Evaluate Capacitance with No Liquid?

Capacitance with No Liquid evaluator uses No Fluid Capacitance = (Capacitance*Plate Height)/((Liquid Level between Plates*Dielectric Constant)+Plate Height) to evaluate the No Fluid Capacitance, The Capacitance with no Liquid formula is defined as the ratio of the amount of electric charge stored on a conductor to a difference in electric potential. No Fluid Capacitance is denoted by Ca symbol.

How to evaluate Capacitance with No Liquid using this online evaluator? To use this online evaluator for Capacitance with No Liquid, enter Capacitance (C), Plate Height (R), Liquid Level between Plates (DL) & Dielectric Constant (μ) and hit the calculate button.

FAQs on Capacitance with No Liquid

What is the formula to find Capacitance with No Liquid?
The formula of Capacitance with No Liquid is expressed as No Fluid Capacitance = (Capacitance*Plate Height)/((Liquid Level between Plates*Dielectric Constant)+Plate Height). Here is an example- 4.713333 = (10.1*1.05)/((0.021*60)+1.05).
How to calculate Capacitance with No Liquid?
With Capacitance (C), Plate Height (R), Liquid Level between Plates (DL) & Dielectric Constant (μ) we can find Capacitance with No Liquid using the formula - No Fluid Capacitance = (Capacitance*Plate Height)/((Liquid Level between Plates*Dielectric Constant)+Plate Height).
Can the Capacitance with No Liquid be negative?
No, the Capacitance with No Liquid, measured in Capacitance cannot be negative.
Which unit is used to measure Capacitance with No Liquid?
Capacitance with No Liquid is usually measured using the Farad[F] for Capacitance. Kilofarad[F], Millifarad[F], Microfarad[F] are the few other units in which Capacitance with No Liquid can be measured.