Bursting Force for Square End Zone Formula

Fx Copy
LaTeX Copy
The Prestress Bursting force represents the resultant of the tensile stress in a transverse direction. Check FAQs
Fbst=F(0.32-0.3(YpoYo))
Fbst - Prestress Bursting force?F - Prestressing Force?Ypo - Side Length of Bearing Plate?Yo - Traverse Dimension of End Zone?

Bursting Force for Square End Zone Example

With values
With units
Only example

Here is how the Bursting Force for Square End Zone equation looks like with Values.

Here is how the Bursting Force for Square End Zone equation looks like with Units.

Here is how the Bursting Force for Square End Zone equation looks like.

68Edit=400Edit(0.32-0.3(5Edit10Edit))
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Structural Engineering » fx Bursting Force for Square End Zone

Bursting Force for Square End Zone Solution

Follow our step by step solution on how to calculate Bursting Force for Square End Zone?

FIRST Step Consider the formula
Fbst=F(0.32-0.3(YpoYo))
Next Step Substitute values of Variables
Fbst=400kN(0.32-0.3(5cm10cm))
Next Step Convert Units
Fbst=400000N(0.32-0.3(0.05m0.1m))
Next Step Prepare to Evaluate
Fbst=400000(0.32-0.3(0.050.1))
Next Step Evaluate
Fbst=68000N
LAST Step Convert to Output's Unit
Fbst=68kN

Bursting Force for Square End Zone Formula Elements

Variables
Prestress Bursting force
The Prestress Bursting force represents the resultant of the tensile stress in a transverse direction.
Symbol: Fbst
Measurement: ForceUnit: kN
Note: Value should be greater than 0.
Prestressing Force
Prestressing Force is the force internally applied to the prestressed concrete section.
Symbol: F
Measurement: ForceUnit: kN
Note: Value should be greater than 0.
Side Length of Bearing Plate
Side Length of Bearing Plate represented the length of the bearing plate in which the burst force is acting.
Symbol: Ypo
Measurement: LengthUnit: cm
Note: Value should be greater than 0.
Traverse Dimension of End Zone
Traverse Dimension of End Zone can be defined as the measurement of bearing plate in traverse direction.
Symbol: Yo
Measurement: LengthUnit: cm
Note: Value should be greater than 0.

Other formulas in Post Tensioned Members category

​Go End Zone Reinforcement along Transmission Length
Ast=2.5Mtσalh
​Go Allowable Stress given End Zone Reinforcement
σal=2.5MtAsth
​Go Prestress in Tendon given Bursting Force for Square End Zone
F=Fbst0.32-0.3(YpoYo)
​Go Length of Side of Bearing Plate given Bursting Force for Square End Zone
Ypo=-((FbstF)-0.320.3)Yo

How to Evaluate Bursting Force for Square End Zone?

Bursting Force for Square End Zone evaluator uses Prestress Bursting force = Prestressing Force*(0.32-0.3*(Side Length of Bearing Plate/Traverse Dimension of End Zone)) to evaluate the Prestress Bursting force, The Bursting Force for Square End Zone iFormula is defined as the resultant of the tensile stress in a transverse direction. Prestress Bursting force is denoted by Fbst symbol.

How to evaluate Bursting Force for Square End Zone using this online evaluator? To use this online evaluator for Bursting Force for Square End Zone, enter Prestressing Force (F), Side Length of Bearing Plate (Ypo) & Traverse Dimension of End Zone (Yo) and hit the calculate button.

FAQs on Bursting Force for Square End Zone

What is the formula to find Bursting Force for Square End Zone?
The formula of Bursting Force for Square End Zone is expressed as Prestress Bursting force = Prestressing Force*(0.32-0.3*(Side Length of Bearing Plate/Traverse Dimension of End Zone)). Here is an example- 0.068 = 400000*(0.32-0.3*(0.05/0.1)).
How to calculate Bursting Force for Square End Zone?
With Prestressing Force (F), Side Length of Bearing Plate (Ypo) & Traverse Dimension of End Zone (Yo) we can find Bursting Force for Square End Zone using the formula - Prestress Bursting force = Prestressing Force*(0.32-0.3*(Side Length of Bearing Plate/Traverse Dimension of End Zone)).
Can the Bursting Force for Square End Zone be negative?
No, the Bursting Force for Square End Zone, measured in Force cannot be negative.
Which unit is used to measure Bursting Force for Square End Zone?
Bursting Force for Square End Zone is usually measured using the Kilonewton[kN] for Force. Newton[kN], Exanewton[kN], Meganewton[kN] are the few other units in which Bursting Force for Square End Zone can be measured.
Copied!