Fx Copy
LaTeX Copy
Bundle Diameter refers to the diameter of the tube bundle within the heat exchanger. Check FAQs
DBundle=DiaO(NT0.175)12.285
DBundle - Bundle Diameter?DiaO - Pipe Outer Diameter in Bundle Diameter?NT - Number of Tubes in Bundle Diameter?

Bundle Diameter for Four Tube Pass Triangular Pitch in Heat Exchanger Example

With values
With units
Only example

Here is how the Bundle Diameter for Four Tube Pass Triangular Pitch in Heat Exchanger equation looks like with Values.

Here is how the Bundle Diameter for Four Tube Pass Triangular Pitch in Heat Exchanger equation looks like with Units.

Here is how the Bundle Diameter for Four Tube Pass Triangular Pitch in Heat Exchanger equation looks like.

517.4497Edit=19.2Edit(325Edit0.175)12.285
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Process Equipment Design » fx Bundle Diameter for Four Tube Pass Triangular Pitch in Heat Exchanger

Bundle Diameter for Four Tube Pass Triangular Pitch in Heat Exchanger Solution

Follow our step by step solution on how to calculate Bundle Diameter for Four Tube Pass Triangular Pitch in Heat Exchanger?

FIRST Step Consider the formula
DBundle=DiaO(NT0.175)12.285
Next Step Substitute values of Variables
DBundle=19.2mm(3250.175)12.285
Next Step Convert Units
DBundle=0.0192m(3250.175)12.285
Next Step Prepare to Evaluate
DBundle=0.0192(3250.175)12.285
Next Step Evaluate
DBundle=0.517449658879305m
Next Step Convert to Output's Unit
DBundle=517.449658879305mm
LAST Step Rounding Answer
DBundle=517.4497mm

Bundle Diameter for Four Tube Pass Triangular Pitch in Heat Exchanger Formula Elements

Variables
Bundle Diameter
Bundle Diameter refers to the diameter of the tube bundle within the heat exchanger.
Symbol: DBundle
Measurement: LengthUnit: mm
Note: Value should be greater than 0.
Pipe Outer Diameter in Bundle Diameter
Pipe Outer Diameter in Bundle Diameter refers to the measurement of the outside or external diameter of a cylindrical pipe. It includes the pipe thickness into it.
Symbol: DiaO
Measurement: LengthUnit: mm
Note: Value should be greater than 0.
Number of Tubes in Bundle Diameter
Number of Tubes in Bundle Diameter in a heat exchanger refers to the count of individual tubes that form the heat transfer surface inside the heat exchanger forming a bundle of tubes.
Symbol: NT
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.

Other Formulas to find Bundle Diameter

​Go Bundle Diameter for Eight Tube Pass Square Pitch in Heat Exchanger
DBundle=DiaO(NT0.0331)12.643
​Go Bundle Diameter for Eight Tube Pass Triangular Pitch in Heat Exchanger
DBundle=DiaO(NT0.0365)12.675
​Go Bundle Diameter for Four Tube Pass Square Pitch in Heat Exchanger
DBundle=DiaO(NT0.158)12.263
​Go Bundle Diameter for One Tube Pass Square Pitch in Heat Exchanger
DBundle=DiaO(NT0.215)12.207

How to Evaluate Bundle Diameter for Four Tube Pass Triangular Pitch in Heat Exchanger?

Bundle Diameter for Four Tube Pass Triangular Pitch in Heat Exchanger evaluator uses Bundle Diameter = Pipe Outer Diameter in Bundle Diameter*(Number of Tubes in Bundle Diameter/0.175)^(1/2.285) to evaluate the Bundle Diameter, The Bundle Diameter for Four Tube Pass Triangular Pitch in Heat Exchanger formula is defined as the diameter of the tube bundle with Four or Multiple tube-pass within the heat exchanger having triangular pitch layout on tube-side. Bundle Diameter is denoted by DBundle symbol.

How to evaluate Bundle Diameter for Four Tube Pass Triangular Pitch in Heat Exchanger using this online evaluator? To use this online evaluator for Bundle Diameter for Four Tube Pass Triangular Pitch in Heat Exchanger, enter Pipe Outer Diameter in Bundle Diameter (DiaO) & Number of Tubes in Bundle Diameter (NT) and hit the calculate button.

FAQs on Bundle Diameter for Four Tube Pass Triangular Pitch in Heat Exchanger

What is the formula to find Bundle Diameter for Four Tube Pass Triangular Pitch in Heat Exchanger?
The formula of Bundle Diameter for Four Tube Pass Triangular Pitch in Heat Exchanger is expressed as Bundle Diameter = Pipe Outer Diameter in Bundle Diameter*(Number of Tubes in Bundle Diameter/0.175)^(1/2.285). Here is an example- 517449.7 = 0.0192*(325/0.175)^(1/2.285).
How to calculate Bundle Diameter for Four Tube Pass Triangular Pitch in Heat Exchanger?
With Pipe Outer Diameter in Bundle Diameter (DiaO) & Number of Tubes in Bundle Diameter (NT) we can find Bundle Diameter for Four Tube Pass Triangular Pitch in Heat Exchanger using the formula - Bundle Diameter = Pipe Outer Diameter in Bundle Diameter*(Number of Tubes in Bundle Diameter/0.175)^(1/2.285).
What are the other ways to Calculate Bundle Diameter?
Here are the different ways to Calculate Bundle Diameter-
  • Bundle Diameter=Pipe Outer Diameter in Bundle Diameter*(Number of Tubes in Bundle Diameter/0.0331)^(1/2.643)OpenImg
  • Bundle Diameter=Pipe Outer Diameter in Bundle Diameter*(Number of Tubes in Bundle Diameter/0.0365)^(1/2.675)OpenImg
  • Bundle Diameter=Pipe Outer Diameter in Bundle Diameter*(Number of Tubes in Bundle Diameter/0.158)^(1/2.263)OpenImg
Can the Bundle Diameter for Four Tube Pass Triangular Pitch in Heat Exchanger be negative?
No, the Bundle Diameter for Four Tube Pass Triangular Pitch in Heat Exchanger, measured in Length cannot be negative.
Which unit is used to measure Bundle Diameter for Four Tube Pass Triangular Pitch in Heat Exchanger?
Bundle Diameter for Four Tube Pass Triangular Pitch in Heat Exchanger is usually measured using the Millimeter[mm] for Length. Meter[mm], Kilometer[mm], Decimeter[mm] are the few other units in which Bundle Diameter for Four Tube Pass Triangular Pitch in Heat Exchanger can be measured.
Copied!