Bottom Product based on Boil-up Ratio Formula

Fx Copy
LaTeX Copy
The Residue flowrate from Distillation Column is the amount of moles of bottom liquid product (Residue) flowing out from the column per unit time. Check FAQs
W=VRv
W - Residue Flowrate from Distillation Column?V - Boil-Up Flowrate to the Distillation Column?Rv - Boil-Up Ratio?

Bottom Product based on Boil-up Ratio Example

With values
With units
Only example

Here is how the Bottom Product based on Boil-up Ratio equation looks like with Values.

Here is how the Bottom Product based on Boil-up Ratio equation looks like with Units.

Here is how the Bottom Product based on Boil-up Ratio equation looks like.

6.0215Edit=11.2Edit1.86Edit
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Mass Transfer Operations » fx Bottom Product based on Boil-up Ratio

Bottom Product based on Boil-up Ratio Solution

Follow our step by step solution on how to calculate Bottom Product based on Boil-up Ratio?

FIRST Step Consider the formula
W=VRv
Next Step Substitute values of Variables
W=11.2mol/s1.86
Next Step Prepare to Evaluate
W=11.21.86
Next Step Evaluate
W=6.02150537634409mol/s
LAST Step Rounding Answer
W=6.0215mol/s

Bottom Product based on Boil-up Ratio Formula Elements

Variables
Residue Flowrate from Distillation Column
The Residue flowrate from Distillation Column is the amount of moles of bottom liquid product (Residue) flowing out from the column per unit time.
Symbol: W
Measurement: Molar Flow RateUnit: mol/s
Note: Value should be greater than 0.
Boil-Up Flowrate to the Distillation Column
The Boil-Up Flowrate to the Distillation Column is the vapour's molar flowrate, leaving the reboiler back into the distillation column.
Symbol: V
Measurement: Molar Flow RateUnit: mol/s
Note: Value should be greater than 0.
Boil-Up Ratio
The Boil-Up Ratio is defined as the ratio of molar flowrate of vapour leaving the reboiler back into the column to the molar flowrate of liquid drawn out as bottom product.
Symbol: Rv
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.

Other formulas in Continuous Distillation category

​Go Murphree Efficiency of Distillation Column Based on Vapour Phase
EMurphree=(yn-yn+1yn*-yn+1)100
​Go Overall Efficiency of Distillation Column
Eoverall=(NthNac)100
​Go External Reflux Ratio
R=L0D
​Go Liquid Reflux Flowrate based on External Reflux Ratio
L0=RD

How to Evaluate Bottom Product based on Boil-up Ratio?

Bottom Product based on Boil-up Ratio evaluator uses Residue Flowrate from Distillation Column = Boil-Up Flowrate to the Distillation Column/Boil-Up Ratio to evaluate the Residue Flowrate from Distillation Column, The Bottom Product based on Boil-up Ratio formula is defined as the ratio of the Boil-up vapor flowrate back to the distillation column to the Boil-up Ratio. Residue Flowrate from Distillation Column is denoted by W symbol.

How to evaluate Bottom Product based on Boil-up Ratio using this online evaluator? To use this online evaluator for Bottom Product based on Boil-up Ratio, enter Boil-Up Flowrate to the Distillation Column (V) & Boil-Up Ratio (Rv) and hit the calculate button.

FAQs on Bottom Product based on Boil-up Ratio

What is the formula to find Bottom Product based on Boil-up Ratio?
The formula of Bottom Product based on Boil-up Ratio is expressed as Residue Flowrate from Distillation Column = Boil-Up Flowrate to the Distillation Column/Boil-Up Ratio. Here is an example- 6.021505 = 11.2/1.86.
How to calculate Bottom Product based on Boil-up Ratio?
With Boil-Up Flowrate to the Distillation Column (V) & Boil-Up Ratio (Rv) we can find Bottom Product based on Boil-up Ratio using the formula - Residue Flowrate from Distillation Column = Boil-Up Flowrate to the Distillation Column/Boil-Up Ratio.
Can the Bottom Product based on Boil-up Ratio be negative?
No, the Bottom Product based on Boil-up Ratio, measured in Molar Flow Rate cannot be negative.
Which unit is used to measure Bottom Product based on Boil-up Ratio?
Bottom Product based on Boil-up Ratio is usually measured using the Mole per Second[mol/s] for Molar Flow Rate. Kilomole per Second[mol/s], Dekamole per Second[mol/s], Mole per Minute[mol/s] are the few other units in which Bottom Product based on Boil-up Ratio can be measured.
Copied!