Fx Copy
LaTeX Copy
BOD Out referred as the amount of dissolved oxygen exits anaerobic digester. Check FAQs
BODout=BODin100-142Px-%SBODin100
BODout - BOD Out?BODin - BOD In?Px - Volatile Solids Produced?%S - Percent Stabilization?

BOD Out given Percent Stabilization Example

With values
With units
Only example

Here is how the BOD Out given Percent Stabilization equation looks like with Values.

Here is how the BOD Out given Percent Stabilization equation looks like with Units.

Here is how the BOD Out given Percent Stabilization equation looks like.

5.0096Edit=164Edit100-142100Edit-10.36Edit164Edit100
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx BOD Out given Percent Stabilization

BOD Out given Percent Stabilization Solution

Follow our step by step solution on how to calculate BOD Out given Percent Stabilization?

FIRST Step Consider the formula
BODout=BODin100-142Px-%SBODin100
Next Step Substitute values of Variables
BODout=164kg/d100-142100kg/d-10.36164kg/d100
Next Step Convert Units
BODout=0.0019kg/s100-1420.0012kg/s-10.360.0019kg/s100
Next Step Prepare to Evaluate
BODout=0.0019100-1420.0012-10.360.0019100
Next Step Evaluate
BODout=5.79814814814797E-05kg/s
Next Step Convert to Output's Unit
BODout=5.00959999999984kg/d
LAST Step Rounding Answer
BODout=5.0096kg/d

BOD Out given Percent Stabilization Formula Elements

Variables
BOD Out
BOD Out referred as the amount of dissolved oxygen exits anaerobic digester.
Symbol: BODout
Measurement: Mass Flow RateUnit: kg/d
Note: Value should be greater than 0.
BOD In
BOD In in anaerobic digester design lies in its role as an indicator of the organic load present in the feedstock. High BOD levels suggest a greater concentration of organic matter.
Symbol: BODin
Measurement: Mass Flow RateUnit: kg/d
Note: Value should be greater than 0.
Volatile Solids Produced
Volatile Solids Produced refers to the organic fraction of the total solids present in the sludge.
Symbol: Px
Measurement: Mass Flow RateUnit: kg/d
Note: Value should be greater than 0.
Percent Stabilization
Percent Stabilization is defined as percentage of bod removal.
Symbol: %S
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.

Other Formulas to find BOD Out

​Go BOD Out given Quantity of Volatile Solids
BODout=BODin-(PxY)(1-kdθc)
​Go BOD Out given Volume of Methane Gas Produced
BODout=(BODin-(VCH45.62)-(1.42Px))

Other formulas in Design of an Anaerobic Digester category

​Go Volume Required for Anaerobic Digester
VT=(θQs)
​Go Hydraulic Retention Time given Volume Required for Anaerobic Digester
θh=(VTQs)
​Go Influent Sludge Flow Rate given Volume Required for Anaerobic Digester
Qs=(VTθ)
​Go Volumetric Loading in Anaerobic Digester
Vl=(BODdayV)

How to Evaluate BOD Out given Percent Stabilization?

BOD Out given Percent Stabilization evaluator uses BOD Out = (BOD In*100-142*Volatile Solids Produced-Percent Stabilization*BOD In)/100 to evaluate the BOD Out, The BOD Out given Percent Stabilization formula is defined as the treated effluent from a wastewater treatment plant. It indicates the remaining organic matter in the effluent that can be decomposed by microorganisms, thus requiring oxygen. Monitoring BOD out is crucial for assessing the performance of the treatment plant and ensuring compliance with environmental regulations. BOD Out is denoted by BODout symbol.

How to evaluate BOD Out given Percent Stabilization using this online evaluator? To use this online evaluator for BOD Out given Percent Stabilization, enter BOD In (BODin), Volatile Solids Produced (Px) & Percent Stabilization (%S) and hit the calculate button.

FAQs on BOD Out given Percent Stabilization

What is the formula to find BOD Out given Percent Stabilization?
The formula of BOD Out given Percent Stabilization is expressed as BOD Out = (BOD In*100-142*Volatile Solids Produced-Percent Stabilization*BOD In)/100. Here is an example- 432829.4 = (0.00189814814814815*100-142*0.00115740740740741-10.36*0.00189814814814815)/100.
How to calculate BOD Out given Percent Stabilization?
With BOD In (BODin), Volatile Solids Produced (Px) & Percent Stabilization (%S) we can find BOD Out given Percent Stabilization using the formula - BOD Out = (BOD In*100-142*Volatile Solids Produced-Percent Stabilization*BOD In)/100.
What are the other ways to Calculate BOD Out?
Here are the different ways to Calculate BOD Out-
  • BOD Out=BOD In-(Volatile Solids Produced/Yield Coefficient)*(1-Endogenous Coefficient*Mean Cell Residence Time)OpenImg
  • BOD Out=(BOD In-(Volume of Methane/5.62)-(1.42*Volatile Solids Produced))OpenImg
Can the BOD Out given Percent Stabilization be negative?
No, the BOD Out given Percent Stabilization, measured in Mass Flow Rate cannot be negative.
Which unit is used to measure BOD Out given Percent Stabilization?
BOD Out given Percent Stabilization is usually measured using the Kilogram per Day[kg/d] for Mass Flow Rate. Kilogram per Second[kg/d], Gram per Second[kg/d], Gram per Hour[kg/d] are the few other units in which BOD Out given Percent Stabilization can be measured.
Copied!