Fx Copy
LaTeX Copy
Bed Slope of Channel refers to the gradient or incline of a channel's bed, influencing the velocity and direction of water flow, typically measured as a ratio or percentage. Check FAQs
s=ss(νsVratio(Nnp)(rpfRrf)23)2
s - Bed Slope of Channel?ss - Bed Slope of Partial Flow?νsVratio - Velocity Ratio?N - Roughness Coefficient for Running Full?np - Roughness Coefficient Partially Full?rpf - Hydraulic Mean Depth for Partially Full?Rrf - Hydraulic Mean Depth while Running Full?

Bed Slope for Full Flow given Velocity Ratio Example

With values
With units
Only example

Here is how the Bed Slope for Full Flow given Velocity Ratio equation looks like with Values.

Here is how the Bed Slope for Full Flow given Velocity Ratio equation looks like with Units.

Here is how the Bed Slope for Full Flow given Velocity Ratio equation looks like.

0.0011Edit=0.0018Edit(0.76Edit(0.74Edit0.9Edit)(3.2Edit5.2Edit)23)2
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Bed Slope for Full Flow given Velocity Ratio

Bed Slope for Full Flow given Velocity Ratio Solution

Follow our step by step solution on how to calculate Bed Slope for Full Flow given Velocity Ratio?

FIRST Step Consider the formula
s=ss(νsVratio(Nnp)(rpfRrf)23)2
Next Step Substitute values of Variables
s=0.0018(0.76(0.740.9)(3.2m5.2m)23)2
Next Step Prepare to Evaluate
s=0.0018(0.76(0.740.9)(3.25.2)23)2
Next Step Evaluate
s=0.00110277248273772
LAST Step Rounding Answer
s=0.0011

Bed Slope for Full Flow given Velocity Ratio Formula Elements

Variables
Bed Slope of Channel
Bed Slope of Channel refers to the gradient or incline of a channel's bed, influencing the velocity and direction of water flow, typically measured as a ratio or percentage.
Symbol: s
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Bed Slope of Partial Flow
Bed Slope of Partial Flow means the slope at which partial flow is occurring.
Symbol: ss
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Velocity Ratio
The Velocity Ratio compares the flow velocity in a partially full pipe to that in a fully running pipe.
Symbol: νsVratio
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Roughness Coefficient for Running Full
The Roughness Coefficient for Running Full accounts for uniform surface resistance affecting flow velocity and friction loss.
Symbol: N
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Roughness Coefficient Partially Full
Roughness Coefficient Partially Full means roughness coefficient of pipe while running partially full.
Symbol: np
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Hydraulic Mean Depth for Partially Full
Hydraulic Mean Depth for Partially Full refers to the cross-sectional area of flow divided by the wetted perimeter, adapting to varying water levels.
Symbol: rpf
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Hydraulic Mean Depth while Running Full
Hydraulic Mean Depth while Running Full refers to the ratio of the pipe's full cross-sectional area to its full wetted perimeter.
Symbol: Rrf
Measurement: LengthUnit: m
Note: Value should be greater than 0.

Other Formulas to find Bed Slope of Channel

​Go Bed Slope for Full Flow given Bed Slope for Partial Flow
s=ssrpfRrf

Other formulas in Bed Slope of Circular Sewer category

​Go Bed Slope for Partial Flow
ss=Rrfsrpf
​Go Bed Slope for Partial Flow given Velocity Ratio
ss=s(νsVratio(Nnp)(rpfRrf)23)2

How to Evaluate Bed Slope for Full Flow given Velocity Ratio?

Bed Slope for Full Flow given Velocity Ratio evaluator uses Bed Slope of Channel = Bed Slope of Partial Flow/(Velocity Ratio/((Roughness Coefficient for Running Full/Roughness Coefficient Partially Full)*(Hydraulic Mean Depth for Partially Full/Hydraulic Mean Depth while Running Full)^(2/3)))^2 to evaluate the Bed Slope of Channel, The Bed Slope for Full Flow given Velocity Ratio is defined as the gradient or incline of a channel's bed, influencing the velocity and direction of water flow, typically measured as a ratio or percentage. Bed Slope of Channel is denoted by s symbol.

How to evaluate Bed Slope for Full Flow given Velocity Ratio using this online evaluator? To use this online evaluator for Bed Slope for Full Flow given Velocity Ratio, enter Bed Slope of Partial Flow (ss), Velocity Ratio (νsVratio), Roughness Coefficient for Running Full (N), Roughness Coefficient Partially Full (np), Hydraulic Mean Depth for Partially Full (rpf) & Hydraulic Mean Depth while Running Full (Rrf) and hit the calculate button.

FAQs on Bed Slope for Full Flow given Velocity Ratio

What is the formula to find Bed Slope for Full Flow given Velocity Ratio?
The formula of Bed Slope for Full Flow given Velocity Ratio is expressed as Bed Slope of Channel = Bed Slope of Partial Flow/(Velocity Ratio/((Roughness Coefficient for Running Full/Roughness Coefficient Partially Full)*(Hydraulic Mean Depth for Partially Full/Hydraulic Mean Depth while Running Full)^(2/3)))^2. Here is an example- 1.225303 = bed_slope_of_partial_flow/(0.76/((0.74/0.9)*(3.2/5.2)^(2/3)))^2.
How to calculate Bed Slope for Full Flow given Velocity Ratio?
With Bed Slope of Partial Flow (ss), Velocity Ratio (νsVratio), Roughness Coefficient for Running Full (N), Roughness Coefficient Partially Full (np), Hydraulic Mean Depth for Partially Full (rpf) & Hydraulic Mean Depth while Running Full (Rrf) we can find Bed Slope for Full Flow given Velocity Ratio using the formula - Bed Slope of Channel = Bed Slope of Partial Flow/(Velocity Ratio/((Roughness Coefficient for Running Full/Roughness Coefficient Partially Full)*(Hydraulic Mean Depth for Partially Full/Hydraulic Mean Depth while Running Full)^(2/3)))^2.
What are the other ways to Calculate Bed Slope of Channel?
Here are the different ways to Calculate Bed Slope of Channel-
  • Bed Slope of Channel=(Bed Slope of Partial Flow*Hydraulic Mean Depth for Partially Full)/Hydraulic Mean Depth while Running FullOpenImg
Copied!