Fx Copy
LaTeX Copy
The thickness of the base plate. Check FAQs
t=n2Pu0.9FyBN
t - Thickness?n - Projection of Base Plate Beyond Edge?Pu - Factored Load?Fy - Yield Load?B - Width?N - Length?

Base Plate Thickness given Projection of Base Plate beyond Flange and Perpendicular to Web Example

With values
With units
Only example

Here is how the Base Plate Thickness given Projection of Base Plate beyond Flange and Perpendicular to Web equation looks like with Values.

Here is how the Base Plate Thickness given Projection of Base Plate beyond Flange and Perpendicular to Web equation looks like with Units.

Here is how the Base Plate Thickness given Projection of Base Plate beyond Flange and Perpendicular to Web equation looks like.

32.8659Edit=72Edit239381Edit0.9350Edit40Edit30Edit

Base Plate Thickness given Projection of Base Plate beyond Flange and Perpendicular to Web Solution

Follow our step by step solution on how to calculate Base Plate Thickness given Projection of Base Plate beyond Flange and Perpendicular to Web?

FIRST Step Consider the formula
t=n2Pu0.9FyBN
Next Step Substitute values of Variables
t=72mm239381kN0.9350kN40mm30mm
Next Step Prepare to Evaluate
t=722393810.93504030
Next Step Evaluate
t=0.0328658572294801m
Next Step Convert to Output's Unit
t=32.8658572294801mm
LAST Step Rounding Answer
t=32.8659mm

Base Plate Thickness given Projection of Base Plate beyond Flange and Perpendicular to Web Formula Elements

Variables
Functions
Thickness
The thickness of the base plate.
Symbol: t
Measurement: LengthUnit: mm
Note: Value should be greater than 0.
Projection of Base Plate Beyond Edge
Projection of base plate beyond edge is distance between base plate beyond edges of the flange and perpendicular to the web.
Symbol: n
Measurement: LengthUnit: mm
Note: Value can be positive or negative.
Factored Load
Factored Load is a load multiplied by a certain factor designated by codes of practice to determine the strength of a structural members.
Symbol: Pu
Measurement: ForceUnit: kN
Note: Value can be positive or negative.
Yield Load
Yield load is the load value at the point of yield; that is, where plastic deformation begins in stress strain curve.
Symbol: Fy
Measurement: ForceUnit: kN
Note: Value can be positive or negative.
Width
The width is parallel to the flanges.
Symbol: B
Measurement: LengthUnit: mm
Note: Value can be positive or negative.
Length
The length of a rectangular base plate for a wide-flange column.
Symbol: N
Measurement: LengthUnit: mm
Note: Value should be greater than 0.
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other Formulas to find Thickness

​Go Base Plate Thickness given Projection of Base Plate beyond Flange and Parallel to Web
t=m2Pu0.9FyBN

Other formulas in Column Base Plate Design category

​Go Specified Compressive Strength of Concrete using Nominal Bearing Strength
f'c=(fp0.85)A1A2
​Go Nominal Bearing Strength of Concrete
fp=f'c0.85A2A1
​Go Area of Base Plate given Nominal Bearing Strength
A1=A2(fpf'c0.85)2
​Go Area of Supporting Concrete given Nominal Bearing Strength
A2=A1((fpf'c0.85)2)

How to Evaluate Base Plate Thickness given Projection of Base Plate beyond Flange and Perpendicular to Web?

Base Plate Thickness given Projection of Base Plate beyond Flange and Perpendicular to Web evaluator uses Thickness = Projection of Base Plate Beyond Edge*sqrt(2*Factored Load/(0.9*Yield Load*Width*Length)) to evaluate the Thickness, The Base Plate Thickness given Projection of Base Plate beyond Flange and Perpendicular to Web formula is defined as thickness of a rectangular base plate for a wide-flange column. Thickness is denoted by t symbol.

How to evaluate Base Plate Thickness given Projection of Base Plate beyond Flange and Perpendicular to Web using this online evaluator? To use this online evaluator for Base Plate Thickness given Projection of Base Plate beyond Flange and Perpendicular to Web, enter Projection of Base Plate Beyond Edge (n), Factored Load (Pu), Yield Load (Fy), Width (B) & Length (N) and hit the calculate button.

FAQs on Base Plate Thickness given Projection of Base Plate beyond Flange and Perpendicular to Web

What is the formula to find Base Plate Thickness given Projection of Base Plate beyond Flange and Perpendicular to Web?
The formula of Base Plate Thickness given Projection of Base Plate beyond Flange and Perpendicular to Web is expressed as Thickness = Projection of Base Plate Beyond Edge*sqrt(2*Factored Load/(0.9*Yield Load*Width*Length)). Here is an example- 32865.86 = 0.072*sqrt(2*39381000/(0.9*350000*0.04*0.03)).
How to calculate Base Plate Thickness given Projection of Base Plate beyond Flange and Perpendicular to Web?
With Projection of Base Plate Beyond Edge (n), Factored Load (Pu), Yield Load (Fy), Width (B) & Length (N) we can find Base Plate Thickness given Projection of Base Plate beyond Flange and Perpendicular to Web using the formula - Thickness = Projection of Base Plate Beyond Edge*sqrt(2*Factored Load/(0.9*Yield Load*Width*Length)). This formula also uses Square Root Function function(s).
What are the other ways to Calculate Thickness?
Here are the different ways to Calculate Thickness-
  • Thickness=Projection of Base Plate Beyond Flange*sqrt(2*Factored Load/(0.9*Yield Load*Width*Length))OpenImg
Can the Base Plate Thickness given Projection of Base Plate beyond Flange and Perpendicular to Web be negative?
No, the Base Plate Thickness given Projection of Base Plate beyond Flange and Perpendicular to Web, measured in Length cannot be negative.
Which unit is used to measure Base Plate Thickness given Projection of Base Plate beyond Flange and Perpendicular to Web?
Base Plate Thickness given Projection of Base Plate beyond Flange and Perpendicular to Web is usually measured using the Millimeter[mm] for Length. Meter[mm], Kilometer[mm], Decimeter[mm] are the few other units in which Base Plate Thickness given Projection of Base Plate beyond Flange and Perpendicular to Web can be measured.
Copied!