Fx Copy
LaTeX Copy
B phase Current is defined as the current flowing through the b-phase in open conductor fault. Check FAQs
Ib=Vb-VcZf
Ib - B Phase Current?Vb - B Phase Voltage?Vc - C Phase Voltage?Zf - Fault Impedance?

B-Phase Current using Fault Impedance (LLF) Example

With values
With units
Only example

Here is how the B-Phase Current using Fault Impedance (LLF) equation looks like with Values.

Here is how the B-Phase Current using Fault Impedance (LLF) equation looks like with Units.

Here is how the B-Phase Current using Fault Impedance (LLF) equation looks like.

-0.4667Edit=16.5Edit-17.2Edit1.5Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx B-Phase Current using Fault Impedance (LLF)

B-Phase Current using Fault Impedance (LLF) Solution

Follow our step by step solution on how to calculate B-Phase Current using Fault Impedance (LLF)?

FIRST Step Consider the formula
Ib=Vb-VcZf
Next Step Substitute values of Variables
Ib=16.5V-17.2V1.5Ω
Next Step Prepare to Evaluate
Ib=16.5-17.21.5
Next Step Evaluate
Ib=-0.466666666666666A
LAST Step Rounding Answer
Ib=-0.4667A

B-Phase Current using Fault Impedance (LLF) Formula Elements

Variables
B Phase Current
B phase Current is defined as the current flowing through the b-phase in open conductor fault.
Symbol: Ib
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.
B Phase Voltage
B phase Voltage is defined as the voltage of b-phase.
Symbol: Vb
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
C Phase Voltage
C phase Voltage is defined as the voltage of c-phase.
Symbol: Vc
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Fault Impedance
Fault Impedance is a measure of the resistance and reactance in an electrical circuit that is used to calculate the fault current that flows through the circuit in the event of a fault.
Symbol: Zf
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.

Other Formulas to find B Phase Current

​Go B-Phase Current (LLF)
Ib=(-1)Ic
​Go B-Phase Current using A-Phase EMF(LLF)
Ib=3EaZ1+Z2

Other formulas in Current category

​Go C-Phase Current(LLF)
Ic=(-1)Ib
​Go Positive Sequence Current (LLF)
I1=(-1)I2
​Go Negative Sequence Current(LLF)
I2=(-1)I1
​Go Positive Sequence Current using Fault Impedance(LLF)
I1=V1-V2Zf

How to Evaluate B-Phase Current using Fault Impedance (LLF)?

B-Phase Current using Fault Impedance (LLF) evaluator uses B Phase Current = (B Phase Voltage-C Phase Voltage)/Fault Impedance to evaluate the B Phase Current, The b-phase Current using Fault Impedance (LLF) formula is defined as the current through any one component comprising a three-phase source or load. Here we have taken the b-phase. B Phase Current is denoted by Ib symbol.

How to evaluate B-Phase Current using Fault Impedance (LLF) using this online evaluator? To use this online evaluator for B-Phase Current using Fault Impedance (LLF), enter B Phase Voltage (Vb), C Phase Voltage (Vc) & Fault Impedance (Zf) and hit the calculate button.

FAQs on B-Phase Current using Fault Impedance (LLF)

What is the formula to find B-Phase Current using Fault Impedance (LLF)?
The formula of B-Phase Current using Fault Impedance (LLF) is expressed as B Phase Current = (B Phase Voltage-C Phase Voltage)/Fault Impedance. Here is an example- 0.6 = (16.5-17.2)/1.5.
How to calculate B-Phase Current using Fault Impedance (LLF)?
With B Phase Voltage (Vb), C Phase Voltage (Vc) & Fault Impedance (Zf) we can find B-Phase Current using Fault Impedance (LLF) using the formula - B Phase Current = (B Phase Voltage-C Phase Voltage)/Fault Impedance.
What are the other ways to Calculate B Phase Current?
Here are the different ways to Calculate B Phase Current-
  • B Phase Current=(-1)*C Phase CurrentOpenImg
  • B Phase Current=(sqrt(3)*A Phase EMF)/(Positive Sequence Impedance+Negative Sequence Impedance)OpenImg
Can the B-Phase Current using Fault Impedance (LLF) be negative?
Yes, the B-Phase Current using Fault Impedance (LLF), measured in Electric Current can be negative.
Which unit is used to measure B-Phase Current using Fault Impedance (LLF)?
B-Phase Current using Fault Impedance (LLF) is usually measured using the Ampere[A] for Electric Current. Milliampere[A], Microampere[A], Centiampere[A] are the few other units in which B-Phase Current using Fault Impedance (LLF) can be measured.