Average Width of Peak given Resolution and Change in Retention Volume Formula

Fx Copy
LaTeX Copy
Average Width of Peaks given RV is the addition of the width of the number of peaks divided by the total number of peaks. Check FAQs
wav_RV=(ΔVrR)
wav_RV - Average Width of Peaks given RV?ΔVr - Change in retention volume?R - Resolution?

Average Width of Peak given Resolution and Change in Retention Volume Example

With values
With units
Only example

Here is how the Average Width of Peak given Resolution and Change in Retention Volume equation looks like with Values.

Here is how the Average Width of Peak given Resolution and Change in Retention Volume equation looks like with Units.

Here is how the Average Width of Peak given Resolution and Change in Retention Volume equation looks like.

0.0008Edit=(9Edit11Edit)
You are here -
HomeIcon Home » Category Chemistry » Category Analytical chemistry » Category Method of Separation Technique » fx Average Width of Peak given Resolution and Change in Retention Volume

Average Width of Peak given Resolution and Change in Retention Volume Solution

Follow our step by step solution on how to calculate Average Width of Peak given Resolution and Change in Retention Volume?

FIRST Step Consider the formula
wav_RV=(ΔVrR)
Next Step Substitute values of Variables
wav_RV=(9L11)
Next Step Convert Units
wav_RV=(0.00911)
Next Step Prepare to Evaluate
wav_RV=(0.00911)
Next Step Evaluate
wav_RV=0.000818181818181818s
LAST Step Rounding Answer
wav_RV=0.0008s

Average Width of Peak given Resolution and Change in Retention Volume Formula Elements

Variables
Average Width of Peaks given RV
Average Width of Peaks given RV is the addition of the width of the number of peaks divided by the total number of peaks.
Symbol: wav_RV
Measurement: TimeUnit: s
Note: Value can be positive or negative.
Change in retention volume
The Change in retention volume is the subtraction of retention volume of solute 2 from solute 1.
Symbol: ΔVr
Measurement: VolumeUnit: L
Note: Value can be positive or negative.
Resolution
The Resolution is defined as the resolving power of the column.
Symbol: R
Measurement: NAUnit: Unitless
Note: Value should be greater than 2.

Other formulas in Retention Volume category

​Go Adjusted Retention Time given Retention Time
t'RT=(tr-tm)
​Go Average Width of Peak given Resolution and Change in Retention Time
wav_RT=(ΔtrR)
​Go Retention Time given Capacity Factor
Tcf=tm(kc+1)
​Go Width of Peak given Number of Theoretical Plates and Retention Time
wNPandRT=4trNTP

How to Evaluate Average Width of Peak given Resolution and Change in Retention Volume?

Average Width of Peak given Resolution and Change in Retention Volume evaluator uses Average Width of Peaks given RV = (Change in retention volume/Resolution) to evaluate the Average Width of Peaks given RV, The Average Width of Peak given Resolution and Change in Retention Volume formula is defined as the ratio of the change in retention volume of a solute to the resolution of the peaks. Average Width of Peaks given RV is denoted by wav_RV symbol.

How to evaluate Average Width of Peak given Resolution and Change in Retention Volume using this online evaluator? To use this online evaluator for Average Width of Peak given Resolution and Change in Retention Volume, enter Change in retention volume (ΔVr) & Resolution (R) and hit the calculate button.

FAQs on Average Width of Peak given Resolution and Change in Retention Volume

What is the formula to find Average Width of Peak given Resolution and Change in Retention Volume?
The formula of Average Width of Peak given Resolution and Change in Retention Volume is expressed as Average Width of Peaks given RV = (Change in retention volume/Resolution). Here is an example- 0.000818 = (0.009/11).
How to calculate Average Width of Peak given Resolution and Change in Retention Volume?
With Change in retention volume (ΔVr) & Resolution (R) we can find Average Width of Peak given Resolution and Change in Retention Volume using the formula - Average Width of Peaks given RV = (Change in retention volume/Resolution).
Can the Average Width of Peak given Resolution and Change in Retention Volume be negative?
Yes, the Average Width of Peak given Resolution and Change in Retention Volume, measured in Time can be negative.
Which unit is used to measure Average Width of Peak given Resolution and Change in Retention Volume?
Average Width of Peak given Resolution and Change in Retention Volume is usually measured using the Second[s] for Time. Millisecond[s], Microsecond[s], Nanosecond[s] are the few other units in which Average Width of Peak given Resolution and Change in Retention Volume can be measured.
Copied!