Average Load Current of Three Phase Uncontrolled Rectifier Formula

Fx Copy
LaTeX Copy
Average load current is a measure of the average current flowing through a load in an electrical circuit over a given period of time. Check FAQs
IL(avg)=33nVmax2πRL
IL(avg) - Average Load Current?n - Winding Ratio?Vmax - Peak Input Voltage?RL - Load Resistance?π - Archimedes' constant?

Average Load Current of Three Phase Uncontrolled Rectifier Example

With values
With units
Only example

Here is how the Average Load Current of Three Phase Uncontrolled Rectifier equation looks like with Values.

Here is how the Average Load Current of Three Phase Uncontrolled Rectifier equation looks like with Units.

Here is how the Average Load Current of Three Phase Uncontrolled Rectifier equation looks like.

390.426Edit=3315Edit220Edit23.14166.99Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power Electronics » fx Average Load Current of Three Phase Uncontrolled Rectifier

Average Load Current of Three Phase Uncontrolled Rectifier Solution

Follow our step by step solution on how to calculate Average Load Current of Three Phase Uncontrolled Rectifier?

FIRST Step Consider the formula
IL(avg)=33nVmax2πRL
Next Step Substitute values of Variables
IL(avg)=3315220V2π6.99Ω
Next Step Substitute values of Constants
IL(avg)=3315220V23.14166.99Ω
Next Step Prepare to Evaluate
IL(avg)=331522023.14166.99
Next Step Evaluate
IL(avg)=390.426041822299A
LAST Step Rounding Answer
IL(avg)=390.426A

Average Load Current of Three Phase Uncontrolled Rectifier Formula Elements

Variables
Constants
Functions
Average Load Current
Average load current is a measure of the average current flowing through a load in an electrical circuit over a given period of time.
Symbol: IL(avg)
Measurement: Electric CurrentUnit: A
Note: Value should be greater than 0.
Winding Ratio
Winding Ratio of an uncontrolled rectifier is the ratio of the number of turns on the primary winding to the number of turns on the secondary winding of the transformer.
Symbol: n
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Peak Input Voltage
Peak Input Voltage is the peak of the alternating voltage provided at the input of any electrical circuit.
Symbol: Vmax
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
Load Resistance
Load Resistance of uncontrolled rectifier is a type of rectifier circuit that uses a resistive load to convert AC voltage to DC voltage.
Symbol: RL
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.
Archimedes' constant
Archimedes' constant is a mathematical constant that represents the ratio of the circumference of a circle to its diameter.
Symbol: π
Value: 3.14159265358979323846264338327950288
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other formulas in Full Wave category

​Go Load Voltage of Full Wave Three Phase Uncontrolled Rectifier
Vac=2nVmaxπ
​Go Power Delivered to Load in Three Phase Uncontrolled Rectifier
Pout=VacVdc
​Go RMS Load Current of Three Phase Uncontrolled Rectifier
IL(rms)=nVmaxRL21+332π
​Go Average Diode Current of Three Phase Uncontrolled Rectifier
Id(avg)=3nVmax2πRL

How to Evaluate Average Load Current of Three Phase Uncontrolled Rectifier?

Average Load Current of Three Phase Uncontrolled Rectifier evaluator uses Average Load Current = (3*sqrt(3)*Winding Ratio*Peak Input Voltage)/(2*pi*Load Resistance) to evaluate the Average Load Current, Average Load Current of Three Phase Uncontrolled Rectifier is the DC current that flows through the load resistor. The average load current of an uncontrolled rectifier is an important parameter that must be considered when designing a rectifier circuit. It is important to choose diodes with a current rating that is greater than the RMS load current in order to prevent the diodes from overheating. Average Load Current is denoted by IL(avg) symbol.

How to evaluate Average Load Current of Three Phase Uncontrolled Rectifier using this online evaluator? To use this online evaluator for Average Load Current of Three Phase Uncontrolled Rectifier, enter Winding Ratio (n), Peak Input Voltage (Vmax) & Load Resistance (RL) and hit the calculate button.

FAQs on Average Load Current of Three Phase Uncontrolled Rectifier

What is the formula to find Average Load Current of Three Phase Uncontrolled Rectifier?
The formula of Average Load Current of Three Phase Uncontrolled Rectifier is expressed as Average Load Current = (3*sqrt(3)*Winding Ratio*Peak Input Voltage)/(2*pi*Load Resistance). Here is an example- 390.426 = (3*sqrt(3)*15*220)/(2*pi*6.99).
How to calculate Average Load Current of Three Phase Uncontrolled Rectifier?
With Winding Ratio (n), Peak Input Voltage (Vmax) & Load Resistance (RL) we can find Average Load Current of Three Phase Uncontrolled Rectifier using the formula - Average Load Current = (3*sqrt(3)*Winding Ratio*Peak Input Voltage)/(2*pi*Load Resistance). This formula also uses Archimedes' constant and Square Root (sqrt) function(s).
Can the Average Load Current of Three Phase Uncontrolled Rectifier be negative?
No, the Average Load Current of Three Phase Uncontrolled Rectifier, measured in Electric Current cannot be negative.
Which unit is used to measure Average Load Current of Three Phase Uncontrolled Rectifier?
Average Load Current of Three Phase Uncontrolled Rectifier is usually measured using the Ampere[A] for Electric Current. Milliampere[A], Microampere[A], Centiampere[A] are the few other units in which Average Load Current of Three Phase Uncontrolled Rectifier can be measured.
Copied!