Average Armature Voltage of Three Phase Full-Converter Drives Formula

Fx Copy
LaTeX Copy
Full Drive Armature Voltage in Three Phase is the average voltage developed at the terminals of the armature of the DC full converter drive. Check FAQs
Va(full_3p)=33Vmcos(α)π
Va(full_3p) - Full Drive Armature Voltage in Three Phase?Vm - Peak Input Voltage?α - Delay Angle of Thyristor?π - Archimedes' constant?

Average Armature Voltage of Three Phase Full-Converter Drives Example

With values
With units
Only example

Here is how the Average Armature Voltage of Three Phase Full-Converter Drives equation looks like with Values.

Here is how the Average Armature Voltage of Three Phase Full-Converter Drives equation looks like with Units.

Here is how the Average Armature Voltage of Three Phase Full-Converter Drives equation looks like.

124.4533Edit=33220Editcos(70Edit)3.1416
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power Electronics » fx Average Armature Voltage of Three Phase Full-Converter Drives

Average Armature Voltage of Three Phase Full-Converter Drives Solution

Follow our step by step solution on how to calculate Average Armature Voltage of Three Phase Full-Converter Drives?

FIRST Step Consider the formula
Va(full_3p)=33Vmcos(α)π
Next Step Substitute values of Variables
Va(full_3p)=33220Vcos(70°)π
Next Step Substitute values of Constants
Va(full_3p)=33220Vcos(70°)3.1416
Next Step Convert Units
Va(full_3p)=33220Vcos(1.2217rad)3.1416
Next Step Prepare to Evaluate
Va(full_3p)=33220cos(1.2217)3.1416
Next Step Evaluate
Va(full_3p)=124.45328796903V
LAST Step Rounding Answer
Va(full_3p)=124.4533V

Average Armature Voltage of Three Phase Full-Converter Drives Formula Elements

Variables
Constants
Functions
Full Drive Armature Voltage in Three Phase
Full Drive Armature Voltage in Three Phase is the average voltage developed at the terminals of the armature of the DC full converter drive.
Symbol: Va(full_3p)
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Peak Input Voltage
Peak input voltage is the peak value of the sinusoidal input voltage Vmsin(wt) to the converter drive.
Symbol: Vm
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
Delay Angle of Thyristor
Delay Angle of Thyristor is the angle at which thyristors are triggered after zero crossing.
Symbol: α
Measurement: AngleUnit: °
Note: Value can be positive or negative.
Archimedes' constant
Archimedes' constant is a mathematical constant that represents the ratio of the circumference of a circle to its diameter.
Symbol: π
Value: 3.14159265358979323846264338327950288
cos
Cosine of an angle is the ratio of the side adjacent to the angle to the hypotenuse of the triangle.
Syntax: cos(Angle)
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other formulas in Three Phase Drives category

​Go Average Field Voltage of Three Phase Semi-Converter Drive
Vf(semi_3p)=3Vm(1+cos(α))2π
​Go Maximum Torque in Induction Motor Drives
ζmax=(32ωs)V12r1+r12+(x1+x2)2
​Go Air Gap Power in Three Phase Induction Motor Drives
Pg=3I22(r2s)
​Go Armature Terminal Voltage in Half-Wave Converter Drives
Vo=(3Vml2π)cos(α)

How to Evaluate Average Armature Voltage of Three Phase Full-Converter Drives?

Average Armature Voltage of Three Phase Full-Converter Drives evaluator uses Full Drive Armature Voltage in Three Phase = (3*sqrt(3)*Peak Input Voltage*cos(Delay Angle of Thyristor))/pi to evaluate the Full Drive Armature Voltage in Three Phase, The Average Armature Voltage of Three Phase Full-Converter Drives formula is the average voltage developed at the terminals of the armature of the DC motor drive. In the above formula, the delay angle of the armature thyristor (αa) is considered. Full Drive Armature Voltage in Three Phase is denoted by Va(full_3p) symbol.

How to evaluate Average Armature Voltage of Three Phase Full-Converter Drives using this online evaluator? To use this online evaluator for Average Armature Voltage of Three Phase Full-Converter Drives, enter Peak Input Voltage (Vm) & Delay Angle of Thyristor (α) and hit the calculate button.

FAQs on Average Armature Voltage of Three Phase Full-Converter Drives

What is the formula to find Average Armature Voltage of Three Phase Full-Converter Drives?
The formula of Average Armature Voltage of Three Phase Full-Converter Drives is expressed as Full Drive Armature Voltage in Three Phase = (3*sqrt(3)*Peak Input Voltage*cos(Delay Angle of Thyristor))/pi. Here is an example- 124.4533 = (3*sqrt(3)*220*cos(1.2217304763958))/pi.
How to calculate Average Armature Voltage of Three Phase Full-Converter Drives?
With Peak Input Voltage (Vm) & Delay Angle of Thyristor (α) we can find Average Armature Voltage of Three Phase Full-Converter Drives using the formula - Full Drive Armature Voltage in Three Phase = (3*sqrt(3)*Peak Input Voltage*cos(Delay Angle of Thyristor))/pi. This formula also uses Archimedes' constant and , Cosine (cos), Square Root (sqrt) function(s).
Can the Average Armature Voltage of Three Phase Full-Converter Drives be negative?
Yes, the Average Armature Voltage of Three Phase Full-Converter Drives, measured in Electric Potential can be negative.
Which unit is used to measure Average Armature Voltage of Three Phase Full-Converter Drives?
Average Armature Voltage of Three Phase Full-Converter Drives is usually measured using the Volt[V] for Electric Potential. Millivolt[V], Microvolt[V], Nanovolt[V] are the few other units in which Average Armature Voltage of Three Phase Full-Converter Drives can be measured.