Armature Terminal Voltage in Half-Wave Converter Drives Formula

Fx Copy
LaTeX Copy
Average Output Voltage of a DC machine drive is the average voltage that is applied to the armature of the DC machine. Check FAQs
Vo=(3Vml2π)cos(α)
Vo - Average Output Voltage?Vml - Maximum Line Voltage?α - Delay Angle of Thyristor?π - Archimedes' constant?

Armature Terminal Voltage in Half-Wave Converter Drives Example

With values
With units
Only example

Here is how the Armature Terminal Voltage in Half-Wave Converter Drives equation looks like with Values.

Here is how the Armature Terminal Voltage in Half-Wave Converter Drives equation looks like with Units.

Here is how the Armature Terminal Voltage in Half-Wave Converter Drives equation looks like.

34.2935Edit=(3210Edit23.1416)cos(70Edit)
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power Electronics » fx Armature Terminal Voltage in Half-Wave Converter Drives

Armature Terminal Voltage in Half-Wave Converter Drives Solution

Follow our step by step solution on how to calculate Armature Terminal Voltage in Half-Wave Converter Drives?

FIRST Step Consider the formula
Vo=(3Vml2π)cos(α)
Next Step Substitute values of Variables
Vo=(3210V2π)cos(70°)
Next Step Substitute values of Constants
Vo=(3210V23.1416)cos(70°)
Next Step Convert Units
Vo=(3210V23.1416)cos(1.2217rad)
Next Step Prepare to Evaluate
Vo=(321023.1416)cos(1.2217)
Next Step Evaluate
Vo=34.2935437618073V
LAST Step Rounding Answer
Vo=34.2935V

Armature Terminal Voltage in Half-Wave Converter Drives Formula Elements

Variables
Constants
Functions
Average Output Voltage
Average Output Voltage of a DC machine drive is the average voltage that is applied to the armature of the DC machine.
Symbol: Vo
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
Maximum Line Voltage
The maximum Line voltage for a DC machine drive is the highest voltage that can be applied to the input of the drive. The maximum line voltage is determined by the design of the drive and the ratings.
Symbol: Vml
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
Delay Angle of Thyristor
Delay Angle of Thyristor is the angle at which thyristors are triggered after zero crossing.
Symbol: α
Measurement: AngleUnit: °
Note: Value can be positive or negative.
Archimedes' constant
Archimedes' constant is a mathematical constant that represents the ratio of the circumference of a circle to its diameter.
Symbol: π
Value: 3.14159265358979323846264338327950288
cos
Cosine of an angle is the ratio of the side adjacent to the angle to the hypotenuse of the triangle.
Syntax: cos(Angle)

Other formulas in Three Phase Drives category

​Go Average Field Voltage of Three Phase Semi-Converter Drive
Vf(semi_3p)=3Vm(1+cos(α))2π
​Go Average Armature Voltage of Three Phase Full-Converter Drives
Va(full_3p)=33Vmcos(α)π
​Go Maximum Torque in Induction Motor Drives
ζmax=(32ωs)V12r1+r12+(x1+x2)2
​Go Air Gap Power in Three Phase Induction Motor Drives
Pg=3I22(r2s)

How to Evaluate Armature Terminal Voltage in Half-Wave Converter Drives?

Armature Terminal Voltage in Half-Wave Converter Drives evaluator uses Average Output Voltage = ((3*Maximum Line Voltage)/(2*pi))*cos(Delay Angle of Thyristor) to evaluate the Average Output Voltage, Armature Terminal Voltage in Half-Wave Converter Drives refers to the voltage applied to the armature (the rotor) of a DC motor. A half-wave converter is an electronic device used to control the voltage supplied to a DC motor's armature, typically by modulating the average voltage to control the motor's speed. Average Output Voltage is denoted by Vo symbol.

How to evaluate Armature Terminal Voltage in Half-Wave Converter Drives using this online evaluator? To use this online evaluator for Armature Terminal Voltage in Half-Wave Converter Drives, enter Maximum Line Voltage (Vml) & Delay Angle of Thyristor (α) and hit the calculate button.

FAQs on Armature Terminal Voltage in Half-Wave Converter Drives

What is the formula to find Armature Terminal Voltage in Half-Wave Converter Drives?
The formula of Armature Terminal Voltage in Half-Wave Converter Drives is expressed as Average Output Voltage = ((3*Maximum Line Voltage)/(2*pi))*cos(Delay Angle of Thyristor). Here is an example- 34.29354 = ((3*210)/(2*pi))*cos(1.2217304763958).
How to calculate Armature Terminal Voltage in Half-Wave Converter Drives?
With Maximum Line Voltage (Vml) & Delay Angle of Thyristor (α) we can find Armature Terminal Voltage in Half-Wave Converter Drives using the formula - Average Output Voltage = ((3*Maximum Line Voltage)/(2*pi))*cos(Delay Angle of Thyristor). This formula also uses Archimedes' constant and Cosine (cos) function(s).
Can the Armature Terminal Voltage in Half-Wave Converter Drives be negative?
No, the Armature Terminal Voltage in Half-Wave Converter Drives, measured in Electric Potential cannot be negative.
Which unit is used to measure Armature Terminal Voltage in Half-Wave Converter Drives?
Armature Terminal Voltage in Half-Wave Converter Drives is usually measured using the Volt[V] for Electric Potential. Millivolt[V], Microvolt[V], Nanovolt[V] are the few other units in which Armature Terminal Voltage in Half-Wave Converter Drives can be measured.