Armature Induced Voltage of Series DC motor given Voltage Formula

Fx Copy
LaTeX Copy
The Armature Voltage is described by making use of Faraday’s law of induction. Induced voltage of a closed circuit is described as rate of change of magnetic flux through that closed circuit. Check FAQs
Va=Vs-Ia(Ra+Rsf)
Va - Armature Voltage?Vs - Supply Voltage?Ia - Armature Current?Ra - Armature Resistance?Rsf - Series Field Resistance?

Armature Induced Voltage of Series DC motor given Voltage Example

With values
With units
Only example

Here is how the Armature Induced Voltage of Series DC motor given Voltage equation looks like with Values.

Here is how the Armature Induced Voltage of Series DC motor given Voltage equation looks like with Units.

Here is how the Armature Induced Voltage of Series DC motor given Voltage equation looks like.

180.9361Edit=240Edit-0.724Edit(80Edit+1.58Edit)
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Machine » fx Armature Induced Voltage of Series DC motor given Voltage

Armature Induced Voltage of Series DC motor given Voltage Solution

Follow our step by step solution on how to calculate Armature Induced Voltage of Series DC motor given Voltage?

FIRST Step Consider the formula
Va=Vs-Ia(Ra+Rsf)
Next Step Substitute values of Variables
Va=240V-0.724A(80Ω+1.58Ω)
Next Step Prepare to Evaluate
Va=240-0.724(80+1.58)
Next Step Evaluate
Va=180.93608V
LAST Step Rounding Answer
Va=180.9361V

Armature Induced Voltage of Series DC motor given Voltage Formula Elements

Variables
Armature Voltage
The Armature Voltage is described by making use of Faraday’s law of induction. Induced voltage of a closed circuit is described as rate of change of magnetic flux through that closed circuit.
Symbol: Va
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Supply Voltage
Supply Voltage is the input voltage being fed to the dc motor circuit. It affects various motor parameters, such as speed, torque, and power consumption.
Symbol: Vs
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
Armature Current
The armature current plays a crucial role in determining the performance and operation of a DC motor. It affects the motor's torque production, speed, and efficiency.
Symbol: Ia
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.
Armature Resistance
The Armature Resistance is the ohmic resistance of the copper winding wires plus the brush resistance in an electrical dc motor.
Symbol: Ra
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.
Series Field Resistance
The Series Field Resistance is resistance just like the field resistance but it is connected to a series with the armature of the dc generator.
Symbol: Rsf
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.

Other formulas in Voltage category

​Go Voltage Equation of Series DC Motor
Vs=Va+Ia(Ra+Rsf)
​Go Voltage of Series DC Motor given Input Power
Vs=PinIa
​Go Input Power of Series DC Motor
Pin=VsIa

How to Evaluate Armature Induced Voltage of Series DC motor given Voltage?

Armature Induced Voltage of Series DC motor given Voltage evaluator uses Armature Voltage = Supply Voltage-Armature Current*(Armature Resistance+Series Field Resistance) to evaluate the Armature Voltage, The Armature Induced Voltage of Series DC motor given Voltage formula is defined as the voltage induced in the armature of the series DC motor. Armature Voltage is denoted by Va symbol.

How to evaluate Armature Induced Voltage of Series DC motor given Voltage using this online evaluator? To use this online evaluator for Armature Induced Voltage of Series DC motor given Voltage, enter Supply Voltage (Vs), Armature Current (Ia), Armature Resistance (Ra) & Series Field Resistance (Rsf) and hit the calculate button.

FAQs on Armature Induced Voltage of Series DC motor given Voltage

What is the formula to find Armature Induced Voltage of Series DC motor given Voltage?
The formula of Armature Induced Voltage of Series DC motor given Voltage is expressed as Armature Voltage = Supply Voltage-Armature Current*(Armature Resistance+Series Field Resistance). Here is an example- 180.2121 = 240-0.724*(80+1.58).
How to calculate Armature Induced Voltage of Series DC motor given Voltage?
With Supply Voltage (Vs), Armature Current (Ia), Armature Resistance (Ra) & Series Field Resistance (Rsf) we can find Armature Induced Voltage of Series DC motor given Voltage using the formula - Armature Voltage = Supply Voltage-Armature Current*(Armature Resistance+Series Field Resistance).
Can the Armature Induced Voltage of Series DC motor given Voltage be negative?
Yes, the Armature Induced Voltage of Series DC motor given Voltage, measured in Electric Potential can be negative.
Which unit is used to measure Armature Induced Voltage of Series DC motor given Voltage?
Armature Induced Voltage of Series DC motor given Voltage is usually measured using the Volt[V] for Electric Potential. Millivolt[V], Microvolt[V], Nanovolt[V] are the few other units in which Armature Induced Voltage of Series DC motor given Voltage can be measured.
Copied!