Area of Underground AC Wire is defined as the cross-sectional area of the wire of an AC supply system. Check FAQs
A=V2L
A - Area of Underground AC Wire?V - Volume Of Conductor?L - Length of Underground AC Wire?

Area using Volume of Conductor Material (2 Phase 4 Wire US) Example

With values
With units
Only example

Here is how the Area using Volume of Conductor Material (2 Phase 4 Wire US) equation looks like with Values.

Here is how the Area using Volume of Conductor Material (2 Phase 4 Wire US) equation looks like with Units.

Here is how the Area using Volume of Conductor Material (2 Phase 4 Wire US) equation looks like.

1.25Edit=60Edit224Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Area using Volume of Conductor Material (2 Phase 4 Wire US)

Area using Volume of Conductor Material (2 Phase 4 Wire US) Solution

Follow our step by step solution on how to calculate Area using Volume of Conductor Material (2 Phase 4 Wire US)?

FIRST Step Consider the formula
A=V2L
Next Step Substitute values of Variables
A=60224m
Next Step Prepare to Evaluate
A=60224
LAST Step Evaluate
A=1.25

Area using Volume of Conductor Material (2 Phase 4 Wire US) Formula Elements

Variables
Area of Underground AC Wire
Area of Underground AC Wire is defined as the cross-sectional area of the wire of an AC supply system.
Symbol: A
Measurement: AreaUnit:
Note: Value can be positive or negative.
Volume Of Conductor
Volume Of Conductor the 3-dimensional space enclosed by a conductor material.
Symbol: V
Measurement: VolumeUnit:
Note: Value should be greater than 0.
Length of Underground AC Wire
Length of Underground AC Wire is the total length of the wire from one end to other end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.

Other Formulas to find Area of Underground AC Wire

​Go Area using Line Losses (2 Phase 4 Wire US)
A=(I2)2ρLPloss

Other formulas in Wire Parameters category

​Go Line Losses using Area of X-Section (2 Phase 4 Wire US)
Ploss=4ρLP2A(Vm2)(cos(Φ)2)
​Go Line Losses (2 Phase 4 Wire US)
Ploss=2(I2)R
​Go Length using Line Losses (2 Phase 4 Wire US)
L=PlossA2(I2)ρ
​Go Length using Area of X-Section (2 Phase 4 Wire US)
L=APloss(Vm2)(cos(Φ))24ρ(P2)

How to Evaluate Area using Volume of Conductor Material (2 Phase 4 Wire US)?

Area using Volume of Conductor Material (2 Phase 4 Wire US) evaluator uses Area of Underground AC Wire = Volume Of Conductor/(2*Length of Underground AC Wire) to evaluate the Area of Underground AC Wire, The Area using Volume of Conductor Material (2 phase 4 wire US) formula is defined as the cross-sectional area simply as the square of the wire's diameter in mils and calls that our area in units of “circular mils.” This makes number handling ever so much easier. Area of Underground AC Wire is denoted by A symbol.

How to evaluate Area using Volume of Conductor Material (2 Phase 4 Wire US) using this online evaluator? To use this online evaluator for Area using Volume of Conductor Material (2 Phase 4 Wire US), enter Volume Of Conductor (V) & Length of Underground AC Wire (L) and hit the calculate button.

FAQs on Area using Volume of Conductor Material (2 Phase 4 Wire US)

What is the formula to find Area using Volume of Conductor Material (2 Phase 4 Wire US)?
The formula of Area using Volume of Conductor Material (2 Phase 4 Wire US) is expressed as Area of Underground AC Wire = Volume Of Conductor/(2*Length of Underground AC Wire). Here is an example- 1.25 = 60/(2*24).
How to calculate Area using Volume of Conductor Material (2 Phase 4 Wire US)?
With Volume Of Conductor (V) & Length of Underground AC Wire (L) we can find Area using Volume of Conductor Material (2 Phase 4 Wire US) using the formula - Area of Underground AC Wire = Volume Of Conductor/(2*Length of Underground AC Wire).
What are the other ways to Calculate Area of Underground AC Wire?
Here are the different ways to Calculate Area of Underground AC Wire-
  • Area of Underground AC Wire=(Current Underground AC^2)*2*Resistivity*Length of Underground AC Wire/Line LossesOpenImg
Can the Area using Volume of Conductor Material (2 Phase 4 Wire US) be negative?
Yes, the Area using Volume of Conductor Material (2 Phase 4 Wire US), measured in Area can be negative.
Which unit is used to measure Area using Volume of Conductor Material (2 Phase 4 Wire US)?
Area using Volume of Conductor Material (2 Phase 4 Wire US) is usually measured using the Square Meter[m²] for Area. Square Kilometer[m²], Square Centimeter[m²], Square Millimeter[m²] are the few other units in which Area using Volume of Conductor Material (2 Phase 4 Wire US) can be measured.
Copied!