Fx Copy
LaTeX Copy
Area of Underground AC Wire is defined as the cross-sectional area of the wire of an AC supply system. Check FAQs
A=ρL2R
A - Area of Underground AC Wire?ρ - Resistivity?L - Length of Underground AC Wire?R - Resistance Underground AC?

Area using Resistance of Natural Wire (2-Phase 3-Wire US) Example

With values
With units
Only example

Here is how the Area using Resistance of Natural Wire (2-Phase 3-Wire US) equation looks like with Values.

Here is how the Area using Resistance of Natural Wire (2-Phase 3-Wire US) equation looks like with Units.

Here is how the Area using Resistance of Natural Wire (2-Phase 3-Wire US) equation looks like.

5.8E-5Edit=1.7E-5Edit24Edit25Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Area using Resistance of Natural Wire (2-Phase 3-Wire US)

Area using Resistance of Natural Wire (2-Phase 3-Wire US) Solution

Follow our step by step solution on how to calculate Area using Resistance of Natural Wire (2-Phase 3-Wire US)?

FIRST Step Consider the formula
A=ρL2R
Next Step Substitute values of Variables
A=1.7E-5Ω*m24m25Ω
Next Step Prepare to Evaluate
A=1.7E-52425
Next Step Evaluate
A=5.76999133448223E-05
LAST Step Rounding Answer
A=5.8E-5

Area using Resistance of Natural Wire (2-Phase 3-Wire US) Formula Elements

Variables
Functions
Area of Underground AC Wire
Area of Underground AC Wire is defined as the cross-sectional area of the wire of an AC supply system.
Symbol: A
Measurement: AreaUnit:
Note: Value can be positive or negative.
Resistivity
Resistivity is the measure of how strongly a material opposes the flow of current through them.
Symbol: ρ
Measurement: Electric ResistivityUnit: Ω*m
Note: Value can be positive or negative.
Length of Underground AC Wire
Length of Underground AC Wire is the total length of the wire from one end to other end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Resistance Underground AC
Resistance Underground AC is defined as the property of the wire or line that opposes the flow of current through it.
Symbol: R
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other Formulas to find Area of Underground AC Wire

​Go Area of X Section using Volume of Conductor Material (2 Phase 3 Wire US)
A=V(2+2)L
​Go Area of X-Section using Line Losses (2-Phase 3-Wire US)
A=(2+2)ρL(P)2Ploss(Vmcos(Φ))2

Other formulas in Wire Parameters category

​Go Line Losses using Volume of Conductor Material (2 Phase 3 Wire US)
Ploss=((2+2)P)2ρ(L)2(Vmcos(Φ))2V
​Go Length using Volume of Conductor Material (2 Phase 3 Wire US)
L=VPloss(cos(Φ)Vm)2ρ((2+2)P2)
​Go Constant using Volume of Conductor Material (2 Phase 3 Wire US)
K=V(cos(Φ))22.914
​Go Angle of PF using Volume of Conductor Material (2 Phase 3 Wire US)
Φ=acos((2.914)KV)

How to Evaluate Area using Resistance of Natural Wire (2-Phase 3-Wire US)?

Area using Resistance of Natural Wire (2-Phase 3-Wire US) evaluator uses Area of Underground AC Wire = Resistivity*Length of Underground AC Wire/(sqrt(2)*Resistance Underground AC) to evaluate the Area of Underground AC Wire, The Area using Resistance of Natural Wire (2-Phase 3-Wire US) formula is defined as the cross-sectional area simply as the square of the wire's diameter in mils and calls that our area in units of “circular mils.” This makes number handling ever so much easier. Area of Underground AC Wire is denoted by A symbol.

How to evaluate Area using Resistance of Natural Wire (2-Phase 3-Wire US) using this online evaluator? To use this online evaluator for Area using Resistance of Natural Wire (2-Phase 3-Wire US), enter Resistivity (ρ), Length of Underground AC Wire (L) & Resistance Underground AC (R) and hit the calculate button.

FAQs on Area using Resistance of Natural Wire (2-Phase 3-Wire US)

What is the formula to find Area using Resistance of Natural Wire (2-Phase 3-Wire US)?
The formula of Area using Resistance of Natural Wire (2-Phase 3-Wire US) is expressed as Area of Underground AC Wire = Resistivity*Length of Underground AC Wire/(sqrt(2)*Resistance Underground AC). Here is an example- 5.8E-5 = 1.7E-05*24/(sqrt(2)*5).
How to calculate Area using Resistance of Natural Wire (2-Phase 3-Wire US)?
With Resistivity (ρ), Length of Underground AC Wire (L) & Resistance Underground AC (R) we can find Area using Resistance of Natural Wire (2-Phase 3-Wire US) using the formula - Area of Underground AC Wire = Resistivity*Length of Underground AC Wire/(sqrt(2)*Resistance Underground AC). This formula also uses Square Root (sqrt) function(s).
What are the other ways to Calculate Area of Underground AC Wire?
Here are the different ways to Calculate Area of Underground AC Wire-
  • Area of Underground AC Wire=Volume Of Conductor/((2+sqrt(2))*Length of Underground AC Wire)OpenImg
  • Area of Underground AC Wire=(2+sqrt(2))*Resistivity*Length of Underground AC Wire*(Power Transmitted)^2/(Line Losses*(Maximum Voltage Underground AC*cos(Phase Difference))^2)OpenImg
Can the Area using Resistance of Natural Wire (2-Phase 3-Wire US) be negative?
Yes, the Area using Resistance of Natural Wire (2-Phase 3-Wire US), measured in Area can be negative.
Which unit is used to measure Area using Resistance of Natural Wire (2-Phase 3-Wire US)?
Area using Resistance of Natural Wire (2-Phase 3-Wire US) is usually measured using the Square Meter[m²] for Area. Square Kilometer[m²], Square Centimeter[m²], Square Millimeter[m²] are the few other units in which Area using Resistance of Natural Wire (2-Phase 3-Wire US) can be measured.
Copied!