Fx Copy
LaTeX Copy
Area of Underground AC Wire is defined as the cross-sectional area of the wire of an AC supply system. Check FAQs
A=(I2)2ρLPloss
A - Area of Underground AC Wire?I - Current Underground AC?ρ - Resistivity?L - Length of Underground AC Wire?Ploss - Line Losses?

Area using Line Losses (2 Phase 4 Wire US) Example

With values
With units
Only example

Here is how the Area using Line Losses (2 Phase 4 Wire US) equation looks like with Values.

Here is how the Area using Line Losses (2 Phase 4 Wire US) equation looks like with Units.

Here is how the Area using Line Losses (2 Phase 4 Wire US) equation looks like.

0.0248Edit=(9Edit2)21.7E-5Edit24Edit2.67Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Area using Line Losses (2 Phase 4 Wire US)

Area using Line Losses (2 Phase 4 Wire US) Solution

Follow our step by step solution on how to calculate Area using Line Losses (2 Phase 4 Wire US)?

FIRST Step Consider the formula
A=(I2)2ρLPloss
Next Step Substitute values of Variables
A=(9A2)21.7E-5Ω*m24m2.67W
Next Step Prepare to Evaluate
A=(92)21.7E-5242.67
Next Step Evaluate
A=0.0247550561797753
LAST Step Rounding Answer
A=0.0248

Area using Line Losses (2 Phase 4 Wire US) Formula Elements

Variables
Area of Underground AC Wire
Area of Underground AC Wire is defined as the cross-sectional area of the wire of an AC supply system.
Symbol: A
Measurement: AreaUnit:
Note: Value can be positive or negative.
Current Underground AC
Current Underground AC is defined as the current flowing through the overhead ac supply wire.
Symbol: I
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.
Resistivity
Resistivity is the measure of how strongly a material opposes the flow of current through them.
Symbol: ρ
Measurement: Electric ResistivityUnit: Ω*m
Note: Value can be positive or negative.
Length of Underground AC Wire
Length of Underground AC Wire is the total length of the wire from one end to other end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Line Losses
Line Losses is defined as the total losses occurring in an Underground AC line when in use.
Symbol: Ploss
Measurement: PowerUnit: W
Note: Value can be positive or negative.

Other Formulas to find Area of Underground AC Wire

​Go Area using Volume of Conductor Material (2 Phase 4 Wire US)
A=V2L

Other formulas in Wire Parameters category

​Go Line Losses using Area of X-Section (2 Phase 4 Wire US)
Ploss=4ρLP2A(Vm2)(cos(Φ)2)
​Go Line Losses (2 Phase 4 Wire US)
Ploss=2(I2)R
​Go Length using Line Losses (2 Phase 4 Wire US)
L=PlossA2(I2)ρ
​Go Length using Area of X-Section (2 Phase 4 Wire US)
L=APloss(Vm2)(cos(Φ))24ρ(P2)

How to Evaluate Area using Line Losses (2 Phase 4 Wire US)?

Area using Line Losses (2 Phase 4 Wire US) evaluator uses Area of Underground AC Wire = (Current Underground AC^2)*2*Resistivity*Length of Underground AC Wire/Line Losses to evaluate the Area of Underground AC Wire, The Area using Line Losses (2 phase 4 wire US) formula is defined as the cross-sectional area simply as the square of the wire's diameter in mils and calls that our area in units of “circular mils.” This makes number handling ever so much easier. Area of Underground AC Wire is denoted by A symbol.

How to evaluate Area using Line Losses (2 Phase 4 Wire US) using this online evaluator? To use this online evaluator for Area using Line Losses (2 Phase 4 Wire US), enter Current Underground AC (I), Resistivity (ρ), Length of Underground AC Wire (L) & Line Losses (Ploss) and hit the calculate button.

FAQs on Area using Line Losses (2 Phase 4 Wire US)

What is the formula to find Area using Line Losses (2 Phase 4 Wire US)?
The formula of Area using Line Losses (2 Phase 4 Wire US) is expressed as Area of Underground AC Wire = (Current Underground AC^2)*2*Resistivity*Length of Underground AC Wire/Line Losses. Here is an example- 0.024755 = (9^2)*2*1.7E-05*24/2.67.
How to calculate Area using Line Losses (2 Phase 4 Wire US)?
With Current Underground AC (I), Resistivity (ρ), Length of Underground AC Wire (L) & Line Losses (Ploss) we can find Area using Line Losses (2 Phase 4 Wire US) using the formula - Area of Underground AC Wire = (Current Underground AC^2)*2*Resistivity*Length of Underground AC Wire/Line Losses.
What are the other ways to Calculate Area of Underground AC Wire?
Here are the different ways to Calculate Area of Underground AC Wire-
  • Area of Underground AC Wire=Volume Of Conductor/(2*Length of Underground AC Wire)OpenImg
Can the Area using Line Losses (2 Phase 4 Wire US) be negative?
Yes, the Area using Line Losses (2 Phase 4 Wire US), measured in Area can be negative.
Which unit is used to measure Area using Line Losses (2 Phase 4 Wire US)?
Area using Line Losses (2 Phase 4 Wire US) is usually measured using the Square Meter[m²] for Area. Square Kilometer[m²], Square Centimeter[m²], Square Millimeter[m²] are the few other units in which Area using Line Losses (2 Phase 4 Wire US) can be measured.
Copied!