Fx Copy
LaTeX Copy
Area of Overhead AC Wire is defined as the cross-sectional area of the wire of an AC supply system. Check FAQs
A=V(3.5)L
A - Area of Overhead AC Wire?V - Volume of Conductor?L - Length of Overhead AC Wire?

Area of X-section using Volume of Conductor Material (3-Phase 4-Wire OS) Example

With values
With units
Only example

Here is how the Area of X-section using Volume of Conductor Material (3-Phase 4-Wire OS) equation looks like with Values.

Here is how the Area of X-section using Volume of Conductor Material (3-Phase 4-Wire OS) equation looks like with Units.

Here is how the Area of X-section using Volume of Conductor Material (3-Phase 4-Wire OS) equation looks like.

0.6988Edit=26Edit(3.5)10.63Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Area of X-section using Volume of Conductor Material (3-Phase 4-Wire OS)

Area of X-section using Volume of Conductor Material (3-Phase 4-Wire OS) Solution

Follow our step by step solution on how to calculate Area of X-section using Volume of Conductor Material (3-Phase 4-Wire OS)?

FIRST Step Consider the formula
A=V(3.5)L
Next Step Substitute values of Variables
A=26(3.5)10.63m
Next Step Prepare to Evaluate
A=26(3.5)10.63
Next Step Evaluate
A=0.698830802311517
LAST Step Rounding Answer
A=0.6988

Area of X-section using Volume of Conductor Material (3-Phase 4-Wire OS) Formula Elements

Variables
Area of Overhead AC Wire
Area of Overhead AC Wire is defined as the cross-sectional area of the wire of an AC supply system.
Symbol: A
Measurement: AreaUnit:
Note: Value should be greater than 0.
Volume of Conductor
Volume of Conductor is the total volume of the material used to make the conductor of an overhead ac line.
Symbol: V
Measurement: VolumeUnit:
Note: Value can be positive or negative.
Length of Overhead AC Wire
Length of Overhead AC Wire is the total length of the wire from one end to other end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.

Other Formulas to find Area of Overhead AC Wire

​Go Area of X-Section(3-Phase 4-Wire OS)
A=2(P2)ρL((cos(Φ))2)Ploss3(Vm2)
​Go Area of X-Section using Resistance (3-Phase 4-Wire OS)
A=ρLR

Other formulas in Wire Parameters category

​Go Constant(3-Phase 4-Wire OS)
K=4(P2)ρ(L2)Ploss(Vm2)
​Go Line Losses(3-Phase 4-Wire OS)
Ploss=(3)((I)2)R
​Go Volume of Conductor Material(3-Phase 4-Wire OS)
V=(3.5)AL
​Go Length of Wire using Area of X-Section(3-Phase 4-Wire OS)
L=3A(Vm2)Ploss(cos(Φ))22ρ(P2)

How to Evaluate Area of X-section using Volume of Conductor Material (3-Phase 4-Wire OS)?

Area of X-section using Volume of Conductor Material (3-Phase 4-Wire OS) evaluator uses Area of Overhead AC Wire = Volume of Conductor/((3.5)*Length of Overhead AC Wire) to evaluate the Area of Overhead AC Wire, The Area of X-section using Volume of Conductor Material (3-phase 4-wire OS) formula is defined as the cross-sectional area simply as the square of the wire's diameter in mils and calls that our area in units of “circular mils.” This makes number handling ever so much easier. Area of Overhead AC Wire is denoted by A symbol.

How to evaluate Area of X-section using Volume of Conductor Material (3-Phase 4-Wire OS) using this online evaluator? To use this online evaluator for Area of X-section using Volume of Conductor Material (3-Phase 4-Wire OS), enter Volume of Conductor (V) & Length of Overhead AC Wire (L) and hit the calculate button.

FAQs on Area of X-section using Volume of Conductor Material (3-Phase 4-Wire OS)

What is the formula to find Area of X-section using Volume of Conductor Material (3-Phase 4-Wire OS)?
The formula of Area of X-section using Volume of Conductor Material (3-Phase 4-Wire OS) is expressed as Area of Overhead AC Wire = Volume of Conductor/((3.5)*Length of Overhead AC Wire). Here is an example- 0.698831 = 26/((3.5)*10.63).
How to calculate Area of X-section using Volume of Conductor Material (3-Phase 4-Wire OS)?
With Volume of Conductor (V) & Length of Overhead AC Wire (L) we can find Area of X-section using Volume of Conductor Material (3-Phase 4-Wire OS) using the formula - Area of Overhead AC Wire = Volume of Conductor/((3.5)*Length of Overhead AC Wire).
What are the other ways to Calculate Area of Overhead AC Wire?
Here are the different ways to Calculate Area of Overhead AC Wire-
  • Area of Overhead AC Wire=2*(Power Transmitted^2)*Resistivity*Length of Overhead AC Wire/(((cos(Phase Difference))^2)*Line Losses*3*(Maximum Voltage Overhead AC^2))OpenImg
  • Area of Overhead AC Wire=Resistivity*Length of Overhead AC Wire/Resistance Overhead ACOpenImg
Can the Area of X-section using Volume of Conductor Material (3-Phase 4-Wire OS) be negative?
No, the Area of X-section using Volume of Conductor Material (3-Phase 4-Wire OS), measured in Area cannot be negative.
Which unit is used to measure Area of X-section using Volume of Conductor Material (3-Phase 4-Wire OS)?
Area of X-section using Volume of Conductor Material (3-Phase 4-Wire OS) is usually measured using the Square Meter[m²] for Area. Square Kilometer[m²], Square Centimeter[m²], Square Millimeter[m²] are the few other units in which Area of X-section using Volume of Conductor Material (3-Phase 4-Wire OS) can be measured.
Copied!