Area of Underground AC Wire is defined as the cross-sectional area of the wire of an AC supply system. Check FAQs
A=V(2+2)L
A - Area of Underground AC Wire?V - Volume Of Conductor?L - Length of Underground AC Wire?

Area of X Section using Volume of Conductor Material (2 Phase 3 Wire US) Example

With values
With units
Only example

Here is how the Area of X Section using Volume of Conductor Material (2 Phase 3 Wire US) equation looks like with Values.

Here is how the Area of X Section using Volume of Conductor Material (2 Phase 3 Wire US) equation looks like with Units.

Here is how the Area of X Section using Volume of Conductor Material (2 Phase 3 Wire US) equation looks like.

0.7322Edit=60Edit(2+2)24Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Area of X Section using Volume of Conductor Material (2 Phase 3 Wire US)

Area of X Section using Volume of Conductor Material (2 Phase 3 Wire US) Solution

Follow our step by step solution on how to calculate Area of X Section using Volume of Conductor Material (2 Phase 3 Wire US)?

FIRST Step Consider the formula
A=V(2+2)L
Next Step Substitute values of Variables
A=60(2+2)24m
Next Step Prepare to Evaluate
A=60(2+2)24
Next Step Evaluate
A=0.732233047033631
LAST Step Rounding Answer
A=0.7322

Area of X Section using Volume of Conductor Material (2 Phase 3 Wire US) Formula Elements

Variables
Functions
Area of Underground AC Wire
Area of Underground AC Wire is defined as the cross-sectional area of the wire of an AC supply system.
Symbol: A
Measurement: AreaUnit:
Note: Value can be positive or negative.
Volume Of Conductor
Volume Of Conductor the 3-dimensional space enclosed by a conductor material.
Symbol: V
Measurement: VolumeUnit:
Note: Value should be greater than 0.
Length of Underground AC Wire
Length of Underground AC Wire is the total length of the wire from one end to other end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other Formulas to find Area of Underground AC Wire

​Go Area of X-Section using Line Losses (2-Phase 3-Wire US)
A=(2+2)ρL(P)2Ploss(Vmcos(Φ))2
​Go Area using Resistance of Natural Wire (2-Phase 3-Wire US)
A=ρL2R

Other formulas in Wire Parameters category

​Go Line Losses using Volume of Conductor Material (2 Phase 3 Wire US)
Ploss=((2+2)P)2ρ(L)2(Vmcos(Φ))2V
​Go Length using Volume of Conductor Material (2 Phase 3 Wire US)
L=VPloss(cos(Φ)Vm)2ρ((2+2)P2)
​Go Constant using Volume of Conductor Material (2 Phase 3 Wire US)
K=V(cos(Φ))22.914
​Go Angle of PF using Volume of Conductor Material (2 Phase 3 Wire US)
Φ=acos((2.914)KV)

How to Evaluate Area of X Section using Volume of Conductor Material (2 Phase 3 Wire US)?

Area of X Section using Volume of Conductor Material (2 Phase 3 Wire US) evaluator uses Area of Underground AC Wire = Volume Of Conductor/((2+sqrt(2))*Length of Underground AC Wire) to evaluate the Area of Underground AC Wire, The Area of X section using Volume of Conductor Material (2 phase 3 wire US) formula is defined as the cross-sectional area simply as the square of the wire's diameter in mils and calls that our area in units of “circular mils.” This makes number handling ever so much easier. Area of Underground AC Wire is denoted by A symbol.

How to evaluate Area of X Section using Volume of Conductor Material (2 Phase 3 Wire US) using this online evaluator? To use this online evaluator for Area of X Section using Volume of Conductor Material (2 Phase 3 Wire US), enter Volume Of Conductor (V) & Length of Underground AC Wire (L) and hit the calculate button.

FAQs on Area of X Section using Volume of Conductor Material (2 Phase 3 Wire US)

What is the formula to find Area of X Section using Volume of Conductor Material (2 Phase 3 Wire US)?
The formula of Area of X Section using Volume of Conductor Material (2 Phase 3 Wire US) is expressed as Area of Underground AC Wire = Volume Of Conductor/((2+sqrt(2))*Length of Underground AC Wire). Here is an example- 0.732233 = 60/((2+sqrt(2))*24).
How to calculate Area of X Section using Volume of Conductor Material (2 Phase 3 Wire US)?
With Volume Of Conductor (V) & Length of Underground AC Wire (L) we can find Area of X Section using Volume of Conductor Material (2 Phase 3 Wire US) using the formula - Area of Underground AC Wire = Volume Of Conductor/((2+sqrt(2))*Length of Underground AC Wire). This formula also uses Square Root (sqrt) function(s).
What are the other ways to Calculate Area of Underground AC Wire?
Here are the different ways to Calculate Area of Underground AC Wire-
  • Area of Underground AC Wire=(2+sqrt(2))*Resistivity*Length of Underground AC Wire*(Power Transmitted)^2/(Line Losses*(Maximum Voltage Underground AC*cos(Phase Difference))^2)OpenImg
  • Area of Underground AC Wire=Resistivity*Length of Underground AC Wire/(sqrt(2)*Resistance Underground AC)OpenImg
Can the Area of X Section using Volume of Conductor Material (2 Phase 3 Wire US) be negative?
Yes, the Area of X Section using Volume of Conductor Material (2 Phase 3 Wire US), measured in Area can be negative.
Which unit is used to measure Area of X Section using Volume of Conductor Material (2 Phase 3 Wire US)?
Area of X Section using Volume of Conductor Material (2 Phase 3 Wire US) is usually measured using the Square Meter[m²] for Area. Square Kilometer[m²], Square Centimeter[m²], Square Millimeter[m²] are the few other units in which Area of X Section using Volume of Conductor Material (2 Phase 3 Wire US) can be measured.
Copied!