Fx Copy
LaTeX Copy
Area of Underground AC Wire is defined as the cross-sectional area of the wire of an AC supply system. Check FAQs
A=ρLR
A - Area of Underground AC Wire?ρ - Resistivity?L - Length of Underground AC Wire?R - Resistance Underground AC?

Area of X-Section using Resistance (1-Phase 2-Wire US) Example

With values
With units
Only example

Here is how the Area of X-Section using Resistance (1-Phase 2-Wire US) equation looks like with Values.

Here is how the Area of X-Section using Resistance (1-Phase 2-Wire US) equation looks like with Units.

Here is how the Area of X-Section using Resistance (1-Phase 2-Wire US) equation looks like.

8.2E-5Edit=1.7E-5Edit24Edit5Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Area of X-Section using Resistance (1-Phase 2-Wire US)

Area of X-Section using Resistance (1-Phase 2-Wire US) Solution

Follow our step by step solution on how to calculate Area of X-Section using Resistance (1-Phase 2-Wire US)?

FIRST Step Consider the formula
A=ρLR
Next Step Substitute values of Variables
A=1.7E-5Ω*m24m5Ω
Next Step Prepare to Evaluate
A=1.7E-5245
Next Step Evaluate
A=8.16E-05
LAST Step Rounding Answer
A=8.2E-5

Area of X-Section using Resistance (1-Phase 2-Wire US) Formula Elements

Variables
Area of Underground AC Wire
Area of Underground AC Wire is defined as the cross-sectional area of the wire of an AC supply system.
Symbol: A
Measurement: AreaUnit:
Note: Value can be positive or negative.
Resistivity
Resistivity is the measure of how strongly a material opposes the flow of current through them.
Symbol: ρ
Measurement: Electric ResistivityUnit: Ω*m
Note: Value can be positive or negative.
Length of Underground AC Wire
Length of Underground AC Wire is the total length of the wire from one end to other end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Resistance Underground AC
Resistance Underground AC is defined as the property of the wire or line that opposes the flow of current through it.
Symbol: R
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.

Other Formulas to find Area of Underground AC Wire

​Go Area of X-Section (1-Phase 2-Wire US)
A=(4)ρL(P)2Ploss(Vmcos(Φ))2
​Go Area of X-Section using Volume of Conductor Material (1-Phase 2-Wire US)
A=V2L
​Go Area of X-Section using Load Current (1-Phase 2-Wire US)
A=2(I)2ρLPloss
​Go Area of X-Section using Line Losses (1-Phase 2-Wire US)
A=(4)ρL(P)2Ploss(Vmcos(Φ))2

Other formulas in Wire Parameters category

​Go Voltage of Conductor Material (1-Phase 2-Wire US)
V=2K(cos(Φ))2
​Go Constant (1-Phase 2-Wire US)
K=4ρ(PL)2Ploss(Vm)2
​Go Length using Area of X-Section (1-Phase 2-Wire US)
L=APloss(Vmcos(Φ))24(P2)ρ
​Go Length using Volume of Conductor Material (1-Phase 2-Wire US)
L=V2A

How to Evaluate Area of X-Section using Resistance (1-Phase 2-Wire US)?

Area of X-Section using Resistance (1-Phase 2-Wire US) evaluator uses Area of Underground AC Wire = Resistivity*Length of Underground AC Wire/Resistance Underground AC to evaluate the Area of Underground AC Wire, The Area of X-Section using Resistance (1-Phase 2-Wire US) formula is defined as the cross-sectional area simply as the square of the wire's diameter in mils and calls that our area in units of “circular mils.” This makes number handling ever so much easier. Area of Underground AC Wire is denoted by A symbol.

How to evaluate Area of X-Section using Resistance (1-Phase 2-Wire US) using this online evaluator? To use this online evaluator for Area of X-Section using Resistance (1-Phase 2-Wire US), enter Resistivity (ρ), Length of Underground AC Wire (L) & Resistance Underground AC (R) and hit the calculate button.

FAQs on Area of X-Section using Resistance (1-Phase 2-Wire US)

What is the formula to find Area of X-Section using Resistance (1-Phase 2-Wire US)?
The formula of Area of X-Section using Resistance (1-Phase 2-Wire US) is expressed as Area of Underground AC Wire = Resistivity*Length of Underground AC Wire/Resistance Underground AC. Here is an example- 8.2E-5 = 1.7E-05*24/5.
How to calculate Area of X-Section using Resistance (1-Phase 2-Wire US)?
With Resistivity (ρ), Length of Underground AC Wire (L) & Resistance Underground AC (R) we can find Area of X-Section using Resistance (1-Phase 2-Wire US) using the formula - Area of Underground AC Wire = Resistivity*Length of Underground AC Wire/Resistance Underground AC.
What are the other ways to Calculate Area of Underground AC Wire?
Here are the different ways to Calculate Area of Underground AC Wire-
  • Area of Underground AC Wire=(4)*Resistivity*Length of Underground AC Wire*(Power Transmitted)^2/(Line Losses*(Maximum Voltage Underground AC*cos(Phase Difference))^2)OpenImg
  • Area of Underground AC Wire=Volume Of Conductor/(2*Length of Underground AC Wire)OpenImg
  • Area of Underground AC Wire=2*(Current Underground AC)^2*Resistivity*Length of Underground AC Wire/(Line Losses)OpenImg
Can the Area of X-Section using Resistance (1-Phase 2-Wire US) be negative?
Yes, the Area of X-Section using Resistance (1-Phase 2-Wire US), measured in Area can be negative.
Which unit is used to measure Area of X-Section using Resistance (1-Phase 2-Wire US)?
Area of X-Section using Resistance (1-Phase 2-Wire US) is usually measured using the Square Meter[m²] for Area. Square Kilometer[m²], Square Centimeter[m²], Square Millimeter[m²] are the few other units in which Area of X-Section using Resistance (1-Phase 2-Wire US) can be measured.
Copied!