Fx Copy
LaTeX Copy
Area of Overhead AC Wire is defined as the cross-sectional area of the wire of an AC supply system. Check FAQs
A=ρL(P)22Ploss(Vmcos(Φ))2
A - Area of Overhead AC Wire?ρ - Resistivity?L - Length of Overhead AC Wire?P - Power Transmitted?Ploss - Line Losses?Vm - Maximum Voltage Overhead AC?Φ - Phase Difference?

Area of X-Section using Line Losses (2-Phase 4-Wire OS) Example

With values
With units
Only example

Here is how the Area of X-Section using Line Losses (2-Phase 4-Wire OS) equation looks like with Values.

Here is how the Area of X-Section using Line Losses (2-Phase 4-Wire OS) equation looks like with Units.

Here is how the Area of X-Section using Line Losses (2-Phase 4-Wire OS) equation looks like.

0.003Edit=1.7E-5Edit10.63Edit(890Edit)228.23Edit(62Editcos(30Edit))2
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Area of X-Section using Line Losses (2-Phase 4-Wire OS)

Area of X-Section using Line Losses (2-Phase 4-Wire OS) Solution

Follow our step by step solution on how to calculate Area of X-Section using Line Losses (2-Phase 4-Wire OS)?

FIRST Step Consider the formula
A=ρL(P)22Ploss(Vmcos(Φ))2
Next Step Substitute values of Variables
A=1.7E-5Ω*m10.63m(890W)228.23W(62Vcos(30°))2
Next Step Convert Units
A=1.7E-5Ω*m10.63m(890W)228.23W(62Vcos(0.5236rad))2
Next Step Prepare to Evaluate
A=1.7E-510.63(890)228.23(62cos(0.5236))2
Next Step Evaluate
A=0.00301639162240292
LAST Step Rounding Answer
A=0.003

Area of X-Section using Line Losses (2-Phase 4-Wire OS) Formula Elements

Variables
Functions
Area of Overhead AC Wire
Area of Overhead AC Wire is defined as the cross-sectional area of the wire of an AC supply system.
Symbol: A
Measurement: AreaUnit:
Note: Value should be greater than 0.
Resistivity
Resistivity is the measure of how strongly a material opposes the flow of current through them.
Symbol: ρ
Measurement: Electric ResistivityUnit: Ω*m
Note: Value can be positive or negative.
Length of Overhead AC Wire
Length of Overhead AC Wire is the total length of the wire from one end to other end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Power Transmitted
Power Transmitted is defined as the product of current and voltage phasor in a overhead ac line at the receiving end.
Symbol: P
Measurement: PowerUnit: W
Note: Value should be greater than 0.
Line Losses
Line Losses is defined as the total losses occurring in an Overhead AC line when in use.
Symbol: Ploss
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Maximum Voltage Overhead AC
Maximum Voltage Overhead AC is defined as the peak amplitude of the AC voltage supplied to the line or wire.
Symbol: Vm
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Phase Difference
Phase Difference is defined as the difference between the phasor of apparent and real power (in degrees) or between voltage and current in an ac circuit.
Symbol: Φ
Measurement: AngleUnit: °
Note: Value should be greater than 0.
cos
Cosine of an angle is the ratio of the side adjacent to the angle to the hypotenuse of the triangle.
Syntax: cos(Angle)

Other Formulas to find Area of Overhead AC Wire

​Go Area of X-Section(2-Phase 4-Wire OS)
A=(P2)ρL((cos(Φ))2)Ploss(Vm2)2
​Go Area of X-Section using Load Current (2-Phase 4-Wire OS)
A=2(I)2ρLPloss

Other formulas in Wire Parameters category

​Go Line Losses(2-Phase 4-Wire OS)
Ploss=(4)((I)2)R
​Go Volume of Conductor Material(2-Phase 4-Wire OS)
V=(4)AL

How to Evaluate Area of X-Section using Line Losses (2-Phase 4-Wire OS)?

Area of X-Section using Line Losses (2-Phase 4-Wire OS) evaluator uses Area of Overhead AC Wire = Resistivity*Length of Overhead AC Wire*(Power Transmitted)^2/(2*Line Losses*(Maximum Voltage Overhead AC*cos(Phase Difference))^2) to evaluate the Area of Overhead AC Wire, The Area of X-Section using Line Losses (2-Phase 4-Wire OS) formula is defined as the cross-sectional area simply as the square of the wire's diameter in mils and calls that our area in units of “circular mils.” This makes number handling ever so much easier. Area of Overhead AC Wire is denoted by A symbol.

How to evaluate Area of X-Section using Line Losses (2-Phase 4-Wire OS) using this online evaluator? To use this online evaluator for Area of X-Section using Line Losses (2-Phase 4-Wire OS), enter Resistivity (ρ), Length of Overhead AC Wire (L), Power Transmitted (P), Line Losses (Ploss), Maximum Voltage Overhead AC (Vm) & Phase Difference (Φ) and hit the calculate button.

FAQs on Area of X-Section using Line Losses (2-Phase 4-Wire OS)

What is the formula to find Area of X-Section using Line Losses (2-Phase 4-Wire OS)?
The formula of Area of X-Section using Line Losses (2-Phase 4-Wire OS) is expressed as Area of Overhead AC Wire = Resistivity*Length of Overhead AC Wire*(Power Transmitted)^2/(2*Line Losses*(Maximum Voltage Overhead AC*cos(Phase Difference))^2). Here is an example- 0.003016 = 1.7E-05*10.63*(890)^2/(2*8.23*(62*cos(0.5235987755982))^2).
How to calculate Area of X-Section using Line Losses (2-Phase 4-Wire OS)?
With Resistivity (ρ), Length of Overhead AC Wire (L), Power Transmitted (P), Line Losses (Ploss), Maximum Voltage Overhead AC (Vm) & Phase Difference (Φ) we can find Area of X-Section using Line Losses (2-Phase 4-Wire OS) using the formula - Area of Overhead AC Wire = Resistivity*Length of Overhead AC Wire*(Power Transmitted)^2/(2*Line Losses*(Maximum Voltage Overhead AC*cos(Phase Difference))^2). This formula also uses Cosine (cos) function(s).
What are the other ways to Calculate Area of Overhead AC Wire?
Here are the different ways to Calculate Area of Overhead AC Wire-
  • Area of Overhead AC Wire=(Power Transmitted^2)*Resistivity*Length of Overhead AC Wire/(((cos(Phase Difference))^2)*Line Losses*(Maximum Voltage Overhead AC^2)*2)OpenImg
  • Area of Overhead AC Wire=2*(Current Overhead AC)^2*Resistivity*Length of Overhead AC Wire/(Line Losses)OpenImg
Can the Area of X-Section using Line Losses (2-Phase 4-Wire OS) be negative?
No, the Area of X-Section using Line Losses (2-Phase 4-Wire OS), measured in Area cannot be negative.
Which unit is used to measure Area of X-Section using Line Losses (2-Phase 4-Wire OS)?
Area of X-Section using Line Losses (2-Phase 4-Wire OS) is usually measured using the Square Meter[m²] for Area. Square Kilometer[m²], Square Centimeter[m²], Square Millimeter[m²] are the few other units in which Area of X-Section using Line Losses (2-Phase 4-Wire OS) can be measured.
Copied!