Area of X-Section (DC Two-Wire US) Formula

Fx Copy
LaTeX Copy
The Area of underground dc wire is the amount of two-dimensional space taken up by an object. Check FAQs
A=2(P2)ρlPline(Vm2)
A - Area of underground dc wire?P - Power Transmitted?ρ - Resistivity?l - Length of Wire DC?Pline - Line Losses?Vm - Maximum Voltage?

Area of X-Section (DC Two-Wire US) Example

With values
With units
Only example

Here is how the Area of X-Section (DC Two-Wire US) equation looks like with Values.

Here is how the Area of X-Section (DC Two-Wire US) equation looks like with Units.

Here is how the Area of X-Section (DC Two-Wire US) equation looks like.

0.0045Edit=2(300Edit2)1.7E-5Edit3.2Edit0.6Edit(60Edit2)
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Area of X-Section (DC Two-Wire US)

Area of X-Section (DC Two-Wire US) Solution

Follow our step by step solution on how to calculate Area of X-Section (DC Two-Wire US)?

FIRST Step Consider the formula
A=2(P2)ρlPline(Vm2)
Next Step Substitute values of Variables
A=2(300W2)1.7E-5Ω*m3.2m0.6W(60V2)
Next Step Prepare to Evaluate
A=2(3002)1.7E-53.20.6(602)
Next Step Evaluate
A=0.00453333333333333
LAST Step Rounding Answer
A=0.0045

Area of X-Section (DC Two-Wire US) Formula Elements

Variables
Area of underground dc wire
The Area of underground dc wire is the amount of two-dimensional space taken up by an object.
Symbol: A
Measurement: AreaUnit:
Note: Value can be positive or negative.
Power Transmitted
Power Transmitted is the amount of power that is transferred from its place of generation to a location where it is applied to perform useful work.
Symbol: P
Measurement: PowerUnit: W
Note: Value should be greater than 0.
Resistivity
Resistivity is the measure of how strongly a material opposes the flow of current through them.
Symbol: ρ
Measurement: Electric ResistivityUnit: Ω*m
Note: Value can be positive or negative.
Length of Wire DC
Length of Wire DC is the measurement or extent of something from end to end.
Symbol: l
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Line Losses
Line Losses is defined as the losses that are produced in the line.
Symbol: Pline
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Maximum Voltage
Maximum Voltage the highest voltage rating for electrical devices.
Symbol: Vm
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.

Other formulas in Wire Parameters category

​Go Volume of Conductor Material using Area and Length(DC Two-Wire US)
V=Al2
​Go Volume of Conductor Material using Load Current (DC Two-Wire US)
V=4ρ(l2)C12Pline
​Go Volume of Conductor Material using Resistance (DC Two-Wire US)
V=4(P2)R1AlPline(Vm2)
​Go Volume of Conductor Material (DC Two-Wire US)
V=4(P2)ρl2Pline(Vm2)

How to Evaluate Area of X-Section (DC Two-Wire US)?

Area of X-Section (DC Two-Wire US) evaluator uses Area of underground dc wire = 2*(Power Transmitted^2)*Resistivity*Length of Wire DC/(Line Losses*(Maximum Voltage^2)) to evaluate the Area of underground dc wire, Area of X-Section (DC Two-Wire US) formula is defined as the cross-sectional area simply as the square of the wire's diameter in mils and calls that our area in units of “circular mils.” This makes number handling ever so much easier. Area of underground dc wire is denoted by A symbol.

How to evaluate Area of X-Section (DC Two-Wire US) using this online evaluator? To use this online evaluator for Area of X-Section (DC Two-Wire US), enter Power Transmitted (P), Resistivity (ρ), Length of Wire DC (l), Line Losses (Pline) & Maximum Voltage (Vm) and hit the calculate button.

FAQs on Area of X-Section (DC Two-Wire US)

What is the formula to find Area of X-Section (DC Two-Wire US)?
The formula of Area of X-Section (DC Two-Wire US) is expressed as Area of underground dc wire = 2*(Power Transmitted^2)*Resistivity*Length of Wire DC/(Line Losses*(Maximum Voltage^2)). Here is an example- 0.004533 = 2*(300^2)*1.7E-05*3.2/(0.6*(60^2)).
How to calculate Area of X-Section (DC Two-Wire US)?
With Power Transmitted (P), Resistivity (ρ), Length of Wire DC (l), Line Losses (Pline) & Maximum Voltage (Vm) we can find Area of X-Section (DC Two-Wire US) using the formula - Area of underground dc wire = 2*(Power Transmitted^2)*Resistivity*Length of Wire DC/(Line Losses*(Maximum Voltage^2)).
Can the Area of X-Section (DC Two-Wire US) be negative?
Yes, the Area of X-Section (DC Two-Wire US), measured in Area can be negative.
Which unit is used to measure Area of X-Section (DC Two-Wire US)?
Area of X-Section (DC Two-Wire US) is usually measured using the Square Meter[m²] for Area. Square Kilometer[m²], Square Centimeter[m²], Square Millimeter[m²] are the few other units in which Area of X-Section (DC Two-Wire US) can be measured.
Copied!