Fx Copy
LaTeX Copy
The Area of Partially Full Sewers refers to the cross-sectional flow area at a given water depth, crucial for hydraulic and flow rate calculations. Check FAQs
a=PqVAVs
a - Area of Partially Full Sewers?Pq - Proportionate Discharge?V - Velocity While Running Full?A - Area of Running Full Sewers?Vs - Velocity in a Partially Running Sewer?

Area of Cross-section while Running Partially Full given Proportionate Discharge Example

With values
With units
Only example

Here is how the Area of Cross-section while Running Partially Full given Proportionate Discharge equation looks like with Values.

Here is how the Area of Cross-section while Running Partially Full given Proportionate Discharge equation looks like with Units.

Here is how the Area of Cross-section while Running Partially Full given Proportionate Discharge equation looks like.

3.7957Edit=0.538Edit6.01Edit5.4Edit4.6Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Area of Cross-section while Running Partially Full given Proportionate Discharge

Area of Cross-section while Running Partially Full given Proportionate Discharge Solution

Follow our step by step solution on how to calculate Area of Cross-section while Running Partially Full given Proportionate Discharge?

FIRST Step Consider the formula
a=PqVAVs
Next Step Substitute values of Variables
a=0.5386.01m/s5.44.6m/s
Next Step Prepare to Evaluate
a=0.5386.015.44.6
Next Step Evaluate
a=3.79570695652174
LAST Step Rounding Answer
a=3.7957

Area of Cross-section while Running Partially Full given Proportionate Discharge Formula Elements

Variables
Area of Partially Full Sewers
The Area of Partially Full Sewers refers to the cross-sectional flow area at a given water depth, crucial for hydraulic and flow rate calculations.
Symbol: a
Measurement: AreaUnit:
Note: Value should be greater than 0.
Proportionate Discharge
Proportionate Discharge is the ratio of discharge while running partially full to running full.
Symbol: Pq
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Velocity While Running Full
Velocity while Running Full refers to the speed of fluid flow in a pipe when it's completely filled, influenced by pipe slope and roughness.
Symbol: V
Measurement: SpeedUnit: m/s
Note: Value should be greater than 0.
Area of Running Full Sewers
The Area of Running Full Sewers refers to the total cross-sectional area of the pipe when it is completely filled with fluid.
Symbol: A
Measurement: AreaUnit:
Note: Value should be greater than 0.
Velocity in a Partially Running Sewer
Velocity in a Partially Running Sewer is the speed of flow when the sewer isn't fully filled, influenced by depth and slope.
Symbol: Vs
Measurement: SpeedUnit: m/s
Note: Value should be greater than 0.

Other Formulas to find Area of Partially Full Sewers

​Go Area of Cross-section while Running Partially Full given Proportionate Area
a=PaA
​Go Area of Cross-Section while Running Partially Full given Discharge
a=qVs

Other formulas in Circular Sewer Section Running Partially Full category

​Go Hydraulic Mean Depth while Running Partially Full given Proportionate Hydraulic Mean Depth
rpf=RrfPhmd
​Go Velocity while Running Partially Full given Proportionate Velocity
Vs=VPv
​Go Roughness Coefficient while Running Partially Full using Proportionate Velocity
np=(NPv)(rpfRrf)23
​Go Hydraulic Mean Depth while Running Partially Full given Proportionate Velocity
rpf=(Pvnp(Rrf)23N)32

How to Evaluate Area of Cross-section while Running Partially Full given Proportionate Discharge?

Area of Cross-section while Running Partially Full given Proportionate Discharge evaluator uses Area of Partially Full Sewers = (Proportionate Discharge*Velocity While Running Full*Area of Running Full Sewers)/Velocity in a Partially Running Sewer to evaluate the Area of Partially Full Sewers, Area of Cross-section while Running Partially Full given Proportionate Discharge is defined as the total cross-sectional area of the pipe when it is completely filled with fluid. Area of Partially Full Sewers is denoted by a symbol.

How to evaluate Area of Cross-section while Running Partially Full given Proportionate Discharge using this online evaluator? To use this online evaluator for Area of Cross-section while Running Partially Full given Proportionate Discharge, enter Proportionate Discharge (Pq), Velocity While Running Full (V), Area of Running Full Sewers (A) & Velocity in a Partially Running Sewer (Vs) and hit the calculate button.

FAQs on Area of Cross-section while Running Partially Full given Proportionate Discharge

What is the formula to find Area of Cross-section while Running Partially Full given Proportionate Discharge?
The formula of Area of Cross-section while Running Partially Full given Proportionate Discharge is expressed as Area of Partially Full Sewers = (Proportionate Discharge*Velocity While Running Full*Area of Running Full Sewers)/Velocity in a Partially Running Sewer. Here is an example- 3.753376 = (0.538*6.01*5.4)/4.6.
How to calculate Area of Cross-section while Running Partially Full given Proportionate Discharge?
With Proportionate Discharge (Pq), Velocity While Running Full (V), Area of Running Full Sewers (A) & Velocity in a Partially Running Sewer (Vs) we can find Area of Cross-section while Running Partially Full given Proportionate Discharge using the formula - Area of Partially Full Sewers = (Proportionate Discharge*Velocity While Running Full*Area of Running Full Sewers)/Velocity in a Partially Running Sewer.
What are the other ways to Calculate Area of Partially Full Sewers?
Here are the different ways to Calculate Area of Partially Full Sewers-
  • Area of Partially Full Sewers=Proportionate Area*Area of Running Full SewersOpenImg
  • Area of Partially Full Sewers=Discharge when Pipe is Running Partially Full/Velocity in a Partially Running SewerOpenImg
Can the Area of Cross-section while Running Partially Full given Proportionate Discharge be negative?
No, the Area of Cross-section while Running Partially Full given Proportionate Discharge, measured in Area cannot be negative.
Which unit is used to measure Area of Cross-section while Running Partially Full given Proportionate Discharge?
Area of Cross-section while Running Partially Full given Proportionate Discharge is usually measured using the Square Meter[m²] for Area. Square Kilometer[m²], Square Centimeter[m²], Square Millimeter[m²] are the few other units in which Area of Cross-section while Running Partially Full given Proportionate Discharge can be measured.
Copied!