Area of Cross-Section of Electrode given Conductance and Conductivity Formula

Fx Copy
LaTeX Copy
The Electrode Cross-sectional Area is the size of the electrodes used in an electrolytic cell. Check FAQs
A=GlK
A - Electrode Cross-sectional Area?G - Conductance?l - Distance between Electrodes?K - Specific Conductance?

Area of Cross-Section of Electrode given Conductance and Conductivity Example

With values
With units
Only example

Here is how the Area of Cross-Section of Electrode given Conductance and Conductivity equation looks like with Values.

Here is how the Area of Cross-Section of Electrode given Conductance and Conductivity equation looks like with Units.

Here is how the Area of Cross-Section of Electrode given Conductance and Conductivity equation looks like.

62.5Edit=50Edit5Edit4Edit
You are here -
HomeIcon Home » Category Chemistry » Category Electrochemistry » Category Conductance and Conductivity » fx Area of Cross-Section of Electrode given Conductance and Conductivity

Area of Cross-Section of Electrode given Conductance and Conductivity Solution

Follow our step by step solution on how to calculate Area of Cross-Section of Electrode given Conductance and Conductivity?

FIRST Step Consider the formula
A=GlK
Next Step Substitute values of Variables
A=505m4S/m
Next Step Convert Units
A=50S5m4S/m
Next Step Prepare to Evaluate
A=5054
LAST Step Evaluate
A=62.5

Area of Cross-Section of Electrode given Conductance and Conductivity Formula Elements

Variables
Electrode Cross-sectional Area
The Electrode Cross-sectional Area is the size of the electrodes used in an electrolytic cell.
Symbol: A
Measurement: AreaUnit:
Note: Value can be positive or negative.
Conductance
Conductance (also known as electrical conductance) is defined as the potential for a substance to conduct electricity.
Symbol: G
Measurement: Electric ConductanceUnit:
Note: Value can be positive or negative.
Distance between Electrodes
The Distance between Electrodes is the separation between two parallel electrodes.
Symbol: l
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Specific Conductance
The Specific Conductance is the ability of a substance to conduct electricity. It is the reciprocal of specific resistance.
Symbol: K
Measurement: Electric ConductivityUnit: S/m
Note: Value can be positive or negative.

Other formulas in Conductance and Conductivity category

​Go Specific Conductance
K=1ρ
​Go Molar Conductance
λ=KM
​Go Equivalent Conductance
E=KV
​Go Molar Conductivity given Molarity
Λm=K1000M

How to Evaluate Area of Cross-Section of Electrode given Conductance and Conductivity?

Area of Cross-Section of Electrode given Conductance and Conductivity evaluator uses Electrode Cross-sectional Area = (Conductance*Distance between Electrodes)/(Specific Conductance) to evaluate the Electrode Cross-sectional Area, The Area of cross-section of electrode given conductance and conductivity formula is defined as the product of conductance and distance between the electrode per specific conductance of the electrolytic conductor. Electrode Cross-sectional Area is denoted by A symbol.

How to evaluate Area of Cross-Section of Electrode given Conductance and Conductivity using this online evaluator? To use this online evaluator for Area of Cross-Section of Electrode given Conductance and Conductivity, enter Conductance (G), Distance between Electrodes (l) & Specific Conductance (K) and hit the calculate button.

FAQs on Area of Cross-Section of Electrode given Conductance and Conductivity

What is the formula to find Area of Cross-Section of Electrode given Conductance and Conductivity?
The formula of Area of Cross-Section of Electrode given Conductance and Conductivity is expressed as Electrode Cross-sectional Area = (Conductance*Distance between Electrodes)/(Specific Conductance). Here is an example- 62.5 = (50*5)/(4).
How to calculate Area of Cross-Section of Electrode given Conductance and Conductivity?
With Conductance (G), Distance between Electrodes (l) & Specific Conductance (K) we can find Area of Cross-Section of Electrode given Conductance and Conductivity using the formula - Electrode Cross-sectional Area = (Conductance*Distance between Electrodes)/(Specific Conductance).
Can the Area of Cross-Section of Electrode given Conductance and Conductivity be negative?
Yes, the Area of Cross-Section of Electrode given Conductance and Conductivity, measured in Area can be negative.
Which unit is used to measure Area of Cross-Section of Electrode given Conductance and Conductivity?
Area of Cross-Section of Electrode given Conductance and Conductivity is usually measured using the Square Meter[m²] for Area. Square Kilometer[m²], Square Centimeter[m²], Square Millimeter[m²] are the few other units in which Area of Cross-Section of Electrode given Conductance and Conductivity can be measured.
Copied!