Fx Copy
LaTeX Copy
The Area of Running Full Sewers refers to the total cross-sectional area of the pipe when it is completely filled with fluid. Check FAQs
A=aqsQratio(Nnp)(R)16
A - Area of Running Full Sewers?a - Area of Partially Full Sewers?qsQratio - Discharge Ratio?N - Roughness Coefficient for Running Full?np - Roughness Coefficient Partially Full?R - Hydraulic Mean Depth Ratio?

Area of Cross-section for Full Flow given Hydraulic Mean Depth and Discharge Ratio Example

With values
With units
Only example

Here is how the Area of Cross-section for Full Flow given Hydraulic Mean Depth and Discharge Ratio equation looks like with Values.

Here is how the Area of Cross-section for Full Flow given Hydraulic Mean Depth and Discharge Ratio equation looks like with Units.

Here is how the Area of Cross-section for Full Flow given Hydraulic Mean Depth and Discharge Ratio equation looks like.

5.4086Edit=3.8Edit0.532Edit(0.74Edit0.9Edit)(0.61Edit)16
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Area of Cross-section for Full Flow given Hydraulic Mean Depth and Discharge Ratio

Area of Cross-section for Full Flow given Hydraulic Mean Depth and Discharge Ratio Solution

Follow our step by step solution on how to calculate Area of Cross-section for Full Flow given Hydraulic Mean Depth and Discharge Ratio?

FIRST Step Consider the formula
A=aqsQratio(Nnp)(R)16
Next Step Substitute values of Variables
A=3.80.532(0.740.9)(0.61)16
Next Step Prepare to Evaluate
A=3.80.532(0.740.9)(0.61)16
Next Step Evaluate
A=5.40857446937071
LAST Step Rounding Answer
A=5.4086

Area of Cross-section for Full Flow given Hydraulic Mean Depth and Discharge Ratio Formula Elements

Variables
Area of Running Full Sewers
The Area of Running Full Sewers refers to the total cross-sectional area of the pipe when it is completely filled with fluid.
Symbol: A
Measurement: AreaUnit:
Note: Value should be greater than 0.
Area of Partially Full Sewers
The Area of Partially Full Sewers refers to the cross-sectional flow area at a given water depth, crucial for hydraulic and flow rate calculations.
Symbol: a
Measurement: AreaUnit:
Note: Value should be greater than 0.
Discharge Ratio
Discharge Ratio is the ratio of discharge at partial flow to discharge at full flow.
Symbol: qsQratio
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Roughness Coefficient for Running Full
The Roughness Coefficient for Running Full accounts for uniform surface resistance affecting flow velocity and friction loss.
Symbol: N
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Roughness Coefficient Partially Full
Roughness Coefficient Partially Full means roughness coefficient of pipe while running partially full.
Symbol: np
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Hydraulic Mean Depth Ratio
The Hydraulic Mean Depth Ratio refers to the ratio of the hydraulic mean depth for a partially full pipe to that when it's running full.
Symbol: R
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.

Other Formulas to find Area of Running Full Sewers

​Go Area of Cross-Section for Full Flow given Hydraulic Mean Depth Ratio
A=aqQ(Nnp)(R)16
​Go Area of Cross-section for Full Flow given Discharge Ratio
A=aqsQratio(Nnp)(rpfRrf)16

Other formulas in Area of Cross Section of Circular Sewer category

​Go Area of Cross-Section for Partial Flow given Hydraulic Mean Depth Ratio
a=A(qQ(Nnp)(R)16)
​Go Area of Cross-Section for Partial Flow given Discharge Ratio
a=A(qsQratio(Nnp)(rpfRrf)16)
​Go Area of Cross-section for Partial Flow given Hydraulic Mean Depth and Discharge Ratio
a=A(qsQratio(Nnp)(R)16)

How to Evaluate Area of Cross-section for Full Flow given Hydraulic Mean Depth and Discharge Ratio?

Area of Cross-section for Full Flow given Hydraulic Mean Depth and Discharge Ratio evaluator uses Area of Running Full Sewers = Area of Partially Full Sewers/(Discharge Ratio/((Roughness Coefficient for Running Full/Roughness Coefficient Partially Full)*(Hydraulic Mean Depth Ratio)^(1/6))) to evaluate the Area of Running Full Sewers, Area of Cross-section for Full Flow given Hydraulic Mean Depth and Discharge Ratio is defined as the total cross-sectional area of the pipe when it is completely filled with fluid. Area of Running Full Sewers is denoted by A symbol.

How to evaluate Area of Cross-section for Full Flow given Hydraulic Mean Depth and Discharge Ratio using this online evaluator? To use this online evaluator for Area of Cross-section for Full Flow given Hydraulic Mean Depth and Discharge Ratio, enter Area of Partially Full Sewers (a), Discharge Ratio (qsQratio), Roughness Coefficient for Running Full (N), Roughness Coefficient Partially Full (np) & Hydraulic Mean Depth Ratio (R) and hit the calculate button.

FAQs on Area of Cross-section for Full Flow given Hydraulic Mean Depth and Discharge Ratio

What is the formula to find Area of Cross-section for Full Flow given Hydraulic Mean Depth and Discharge Ratio?
The formula of Area of Cross-section for Full Flow given Hydraulic Mean Depth and Discharge Ratio is expressed as Area of Running Full Sewers = Area of Partially Full Sewers/(Discharge Ratio/((Roughness Coefficient for Running Full/Roughness Coefficient Partially Full)*(Hydraulic Mean Depth Ratio)^(1/6))). Here is an example- 5.408574 = 3.8/(0.532/((0.74/0.9)*(0.61)^(1/6))).
How to calculate Area of Cross-section for Full Flow given Hydraulic Mean Depth and Discharge Ratio?
With Area of Partially Full Sewers (a), Discharge Ratio (qsQratio), Roughness Coefficient for Running Full (N), Roughness Coefficient Partially Full (np) & Hydraulic Mean Depth Ratio (R) we can find Area of Cross-section for Full Flow given Hydraulic Mean Depth and Discharge Ratio using the formula - Area of Running Full Sewers = Area of Partially Full Sewers/(Discharge Ratio/((Roughness Coefficient for Running Full/Roughness Coefficient Partially Full)*(Hydraulic Mean Depth Ratio)^(1/6))).
What are the other ways to Calculate Area of Running Full Sewers?
Here are the different ways to Calculate Area of Running Full Sewers-
  • Area of Running Full Sewers=Area of Partially Full Sewers/((Discharge when Pipe is Running Partially Full/Discharge when Pipe is Running Full)/((Roughness Coefficient for Running Full/Roughness Coefficient Partially Full)*(Hydraulic Mean Depth Ratio)^(1/6)))OpenImg
  • Area of Running Full Sewers=Area of Partially Full Sewers/(Discharge Ratio/((Roughness Coefficient for Running Full/Roughness Coefficient Partially Full)*(Hydraulic Mean Depth for Partially Full/Hydraulic Mean Depth while Running Full)^(1/6)))OpenImg
Can the Area of Cross-section for Full Flow given Hydraulic Mean Depth and Discharge Ratio be negative?
No, the Area of Cross-section for Full Flow given Hydraulic Mean Depth and Discharge Ratio, measured in Area cannot be negative.
Which unit is used to measure Area of Cross-section for Full Flow given Hydraulic Mean Depth and Discharge Ratio?
Area of Cross-section for Full Flow given Hydraulic Mean Depth and Discharge Ratio is usually measured using the Square Meter[m²] for Area. Square Kilometer[m²], Square Centimeter[m²], Square Millimeter[m²] are the few other units in which Area of Cross-section for Full Flow given Hydraulic Mean Depth and Discharge Ratio can be measured.
Copied!