Area of Channel with known Conveyance of Channel at Section 1 Formula

Fx Copy
LaTeX Copy
Area of Channel Section 1 is the enclosed surface area, the product of length and breadth. Check FAQs
A1=K1nR123
A1 - Area of Channel Section 1?K1 - Conveyance of Channel at End Sections at (1)?n - Manning’s Roughness Coefficient?R1 - Hydraulics Radius of Channel Section 1?

Area of Channel with known Conveyance of Channel at Section 1 Example

With values
With units
Only example

Here is how the Area of Channel with known Conveyance of Channel at Section 1 equation looks like with Values.

Here is how the Area of Channel with known Conveyance of Channel at Section 1 equation looks like with Units.

Here is how the Area of Channel with known Conveyance of Channel at Section 1 equation looks like.

494.221Edit=1824Edit0.412Edit1.875Edit23
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Engineering Hydrology » fx Area of Channel with known Conveyance of Channel at Section 1

Area of Channel with known Conveyance of Channel at Section 1 Solution

Follow our step by step solution on how to calculate Area of Channel with known Conveyance of Channel at Section 1?

FIRST Step Consider the formula
A1=K1nR123
Next Step Substitute values of Variables
A1=18240.4121.875m23
Next Step Prepare to Evaluate
A1=18240.4121.87523
Next Step Evaluate
A1=494.221007817188
LAST Step Rounding Answer
A1=494.221

Area of Channel with known Conveyance of Channel at Section 1 Formula Elements

Variables
Area of Channel Section 1
Area of Channel Section 1 is the enclosed surface area, the product of length and breadth.
Symbol: A1
Measurement: AreaUnit:
Note: Value should be greater than 0.
Conveyance of Channel at End Sections at (1)
Conveyance of Channel at End Sections at (1) represents the carrying capacity of a stream cross-section based upon its geometry and roughness characteristics.
Symbol: K1
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Manning’s Roughness Coefficient
Manning’s Roughness Coefficient represents the roughness or friction applied to the flow by the channel.
Symbol: n
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Hydraulics Radius of Channel Section 1
Hydraulics Radius of Channel Section 1 is the ratio of the cross-sectional area of a channel or pipe in which a fluid is flowing to the wet perimeter of the conduit.
Symbol: R1
Measurement: LengthUnit: m
Note: Value should be greater than 0.

Other formulas in Non Uniform Flow category

​Go Conveyance of Channel at End Sections at 1
K1=(1n)A1R123
​Go Length of Reach given Average Energy Slope for Non-Uniform Flow
L=hfSfavg
​Go Frictional Loss given Average Energy Slope
hf=SfavgL
​Go Average Energy Slope given Frictional Loss
Sfavg=hfL

How to Evaluate Area of Channel with known Conveyance of Channel at Section 1?

Area of Channel with known Conveyance of Channel at Section 1 evaluator uses Area of Channel Section 1 = (Conveyance of Channel at End Sections at (1)*Manning’s Roughness Coefficient)/Hydraulics Radius of Channel Section 1^(2/3) to evaluate the Area of Channel Section 1, The Area of Channel with known Conveyance of Channel at Section 1 formula is defined as representing the area of a stream cross-section based upon its geometry and roughness characteristics alone and is independent of the streambed slope. Area of Channel Section 1 is denoted by A1 symbol.

How to evaluate Area of Channel with known Conveyance of Channel at Section 1 using this online evaluator? To use this online evaluator for Area of Channel with known Conveyance of Channel at Section 1, enter Conveyance of Channel at End Sections at (1) (K1), Manning’s Roughness Coefficient (n) & Hydraulics Radius of Channel Section 1 (R1) and hit the calculate button.

FAQs on Area of Channel with known Conveyance of Channel at Section 1

What is the formula to find Area of Channel with known Conveyance of Channel at Section 1?
The formula of Area of Channel with known Conveyance of Channel at Section 1 is expressed as Area of Channel Section 1 = (Conveyance of Channel at End Sections at (1)*Manning’s Roughness Coefficient)/Hydraulics Radius of Channel Section 1^(2/3). Here is an example- 494.221 = (1824*0.412)/1.875^(2/3).
How to calculate Area of Channel with known Conveyance of Channel at Section 1?
With Conveyance of Channel at End Sections at (1) (K1), Manning’s Roughness Coefficient (n) & Hydraulics Radius of Channel Section 1 (R1) we can find Area of Channel with known Conveyance of Channel at Section 1 using the formula - Area of Channel Section 1 = (Conveyance of Channel at End Sections at (1)*Manning’s Roughness Coefficient)/Hydraulics Radius of Channel Section 1^(2/3).
Can the Area of Channel with known Conveyance of Channel at Section 1 be negative?
No, the Area of Channel with known Conveyance of Channel at Section 1, measured in Area cannot be negative.
Which unit is used to measure Area of Channel with known Conveyance of Channel at Section 1?
Area of Channel with known Conveyance of Channel at Section 1 is usually measured using the Square Meter[m²] for Area. Square Kilometer[m²], Square Centimeter[m²], Square Millimeter[m²] are the few other units in which Area of Channel with known Conveyance of Channel at Section 1 can be measured.
Copied!