Aquifer Thickness During Pumping is the thickness of aquifer during pumping stage. Check FAQs
bp=Q2.72Kw(h2-h1)log((r2r1),10)
bp - Aquifer Thickness During Pumping?Q - Discharge?Kw - Coefficient of Permeability?h2 - Depth of Water 2?h1 - Depth of Water 1?r2 - Radial Distance at Observation Well 2?r1 - Radial Distance at Observation Well 1?

Aquifer Thickness given Depth of Water in Two Wells Example

With values
With units
Only example

Here is how the Aquifer Thickness given Depth of Water in Two Wells equation looks like with Values.

Here is how the Aquifer Thickness given Depth of Water in Two Wells equation looks like with Units.

Here is how the Aquifer Thickness given Depth of Water in Two Wells equation looks like.

2.3615Edit=1.01Edit2.721125Edit(17.8644Edit-17.85Edit)log((10Edit1.07Edit),10)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Aquifer Thickness given Depth of Water in Two Wells

Aquifer Thickness given Depth of Water in Two Wells Solution

Follow our step by step solution on how to calculate Aquifer Thickness given Depth of Water in Two Wells?

FIRST Step Consider the formula
bp=Q2.72Kw(h2-h1)log((r2r1),10)
Next Step Substitute values of Variables
bp=1.01m³/s2.721125cm/s(17.8644m-17.85m)log((10m1.07m),10)
Next Step Convert Units
bp=1.01m³/s2.7211.25m/s(17.8644m-17.85m)log((10m1.07m),10)
Next Step Prepare to Evaluate
bp=1.012.7211.25(17.8644-17.85)log((101.07),10)
Next Step Evaluate
bp=2.36151065604315m
LAST Step Rounding Answer
bp=2.3615m

Aquifer Thickness given Depth of Water in Two Wells Formula Elements

Variables
Functions
Aquifer Thickness During Pumping
Aquifer Thickness During Pumping is the thickness of aquifer during pumping stage.
Symbol: bp
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Discharge
Discharge is the flow rate of water that is extracted from or injected into a well.
Symbol: Q
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value can be positive or negative.
Coefficient of Permeability
Coefficient of Permeability is the velocity in meters or centimeters per second of water through soils.
Symbol: Kw
Measurement: SpeedUnit: cm/s
Note: Value should be greater than 0.
Depth of Water 2
Depth of water 2 means the depth of the water in 2nd well.
Symbol: h2
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Depth of Water 1
Depth of Water 1 is the depth of water in the 1st considered well.
Symbol: h1
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Radial Distance at Observation Well 2
Radial Distance at Observation Well 2 is the value of radial distance from well 2 when we have prior information of other parameters used.
Symbol: r2
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Radial Distance at Observation Well 1
Radial Distance at Observation Well 1 is the value of radial distance from well 1 when we have prior information of other parameters used.
Symbol: r1
Measurement: LengthUnit: m
Note: Value should be greater than 0.
log
Logarithmic function is an inverse function to exponentiation.
Syntax: log(Base, Number)

Other Formulas to find Aquifer Thickness During Pumping

​Go Thickness of Confined Aquifer given Discharge in Confined Aquifer
bp=Q2πKw(Hi-hw)log((Rwr),e)

Other formulas in Aquifer Thickness category

​Go Aquifer Thickness from Impermeable Layer given Discharge in Confined Aquifer
Hi=hw+(Qlog((Rwr),e)2πKwbw)
​Go Thickness of Confined Aquifer given Discharge in Confined Aquifer with Base 10
taq=Qc2.72KWH(bw-hw)log((Rwr),10)

How to Evaluate Aquifer Thickness given Depth of Water in Two Wells?

Aquifer Thickness given Depth of Water in Two Wells evaluator uses Aquifer Thickness During Pumping = Discharge/((2.72*Coefficient of Permeability*(Depth of Water 2-Depth of Water 1))/(log((Radial Distance at Observation Well 2/Radial Distance at Observation Well 1),10))) to evaluate the Aquifer Thickness During Pumping, The Aquifer Thickness given Depth of Water in Two Wells formula is defined as the calculation of the value of aquifer thickness when we have prior information of depth of water in two wells. Aquifer Thickness During Pumping is denoted by bp symbol.

How to evaluate Aquifer Thickness given Depth of Water in Two Wells using this online evaluator? To use this online evaluator for Aquifer Thickness given Depth of Water in Two Wells, enter Discharge (Q), Coefficient of Permeability (Kw), Depth of Water 2 (h2), Depth of Water 1 (h1), Radial Distance at Observation Well 2 (r2) & Radial Distance at Observation Well 1 (r1) and hit the calculate button.

FAQs on Aquifer Thickness given Depth of Water in Two Wells

What is the formula to find Aquifer Thickness given Depth of Water in Two Wells?
The formula of Aquifer Thickness given Depth of Water in Two Wells is expressed as Aquifer Thickness During Pumping = Discharge/((2.72*Coefficient of Permeability*(Depth of Water 2-Depth of Water 1))/(log((Radial Distance at Observation Well 2/Radial Distance at Observation Well 1),10))). Here is an example- 2.656699 = 1.01/((2.72*11.25*(17.8644-17.85))/(log((10/1.07),10))).
How to calculate Aquifer Thickness given Depth of Water in Two Wells?
With Discharge (Q), Coefficient of Permeability (Kw), Depth of Water 2 (h2), Depth of Water 1 (h1), Radial Distance at Observation Well 2 (r2) & Radial Distance at Observation Well 1 (r1) we can find Aquifer Thickness given Depth of Water in Two Wells using the formula - Aquifer Thickness During Pumping = Discharge/((2.72*Coefficient of Permeability*(Depth of Water 2-Depth of Water 1))/(log((Radial Distance at Observation Well 2/Radial Distance at Observation Well 1),10))). This formula also uses Logarithmic Inverse (log) function(s).
What are the other ways to Calculate Aquifer Thickness During Pumping?
Here are the different ways to Calculate Aquifer Thickness During Pumping-
  • Aquifer Thickness During Pumping=Discharge/((2*pi*Coefficient of Permeability*(Initial Aquifer Thickness-Depth of Water))/(log((Radius of Influence/Radius of Well),e)))OpenImg
Can the Aquifer Thickness given Depth of Water in Two Wells be negative?
No, the Aquifer Thickness given Depth of Water in Two Wells, measured in Length cannot be negative.
Which unit is used to measure Aquifer Thickness given Depth of Water in Two Wells?
Aquifer Thickness given Depth of Water in Two Wells is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Aquifer Thickness given Depth of Water in Two Wells can be measured.
Copied!