Approximate Time Required to Cover Area of Land Irrigated with Water Formula

Fx Copy
LaTeX Copy
Time required to cover the given area with water is the Time required for water to cover an area. Check FAQs
t=2.3(Yf)log10(QQ-fA)
t - Time Required to Cover the Given Area With Water?Y - Depth of Water Flowing Over the Border Strip?f - Rate of Infiltration of Soil?Q - Discharge Through the Supply Ditch?A - Area of Land Strip to be Irrigated?

Approximate Time Required to Cover Area of Land Irrigated with Water Example

With values
With units
Only example

Here is how the Approximate Time Required to Cover Area of Land Irrigated with Water equation looks like with Values.

Here is how the Approximate Time Required to Cover Area of Land Irrigated with Water equation looks like with Units.

Here is how the Approximate Time Required to Cover Area of Land Irrigated with Water equation looks like.

0.6501Edit=2.3(0.1Edit0.05Edit)log10(72Edit72Edit-0.05Edit400Edit)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Irrigation Engineering » fx Approximate Time Required to Cover Area of Land Irrigated with Water

Approximate Time Required to Cover Area of Land Irrigated with Water Solution

Follow our step by step solution on how to calculate Approximate Time Required to Cover Area of Land Irrigated with Water?

FIRST Step Consider the formula
t=2.3(Yf)log10(QQ-fA)
Next Step Substitute values of Variables
t=2.3(0.1m/s0.05cm)log10(72m³/s72m³/s-0.05cm400)
Next Step Prepare to Evaluate
t=2.3(0.10.05)log10(7272-0.05400)
Next Step Evaluate
t=0.650114102863759s
LAST Step Rounding Answer
t=0.6501s

Approximate Time Required to Cover Area of Land Irrigated with Water Formula Elements

Variables
Functions
Time Required to Cover the Given Area With Water
Time required to cover the given area with water is the Time required for water to cover an area.
Symbol: t
Measurement: TimeUnit: s
Note: Value should be greater than 0.
Depth of Water Flowing Over the Border Strip
Depth of water flowing over the border strip.
Symbol: Y
Measurement: SpeedUnit: m/s
Note: Value should be greater than 0.
Rate of Infiltration of Soil
Rate of infiltration of soil is a measure of how fast water enters the soil, typically expressed in inches per hour.
Symbol: f
Measurement: LengthUnit: cm
Note: Value should be greater than 0.
Discharge Through the Supply Ditch
Discharge through the supply ditch.
Symbol: Q
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Area of Land Strip to be Irrigated
Area of land strip to be irrigated.
Symbol: A
Measurement: AreaUnit:
Note: Value should be greater than 0.
log10
The common logarithm, also known as the base-10 logarithm or the decimal logarithm, is a mathematical function that is the inverse of the exponential function.
Syntax: log10(Number)

Other formulas in Irrigation and Methods of Irrigation category

​Go Maximum Area that can be Irrigated with Supply Ditch of Discharge Q
Amax=Qf
​Go Determination of Supply Ditch of Discharge Q when Maximum Area is Irrigated
Q=(Amax)(f)
​Go Soil Infiltration Capacity when Maximum Area is Irrigated
f=QAmax

How to Evaluate Approximate Time Required to Cover Area of Land Irrigated with Water?

Approximate Time Required to Cover Area of Land Irrigated with Water evaluator uses Time Required to Cover the Given Area With Water = 2.3*(Depth of Water Flowing Over the Border Strip/Rate of Infiltration of Soil)*log10(Discharge Through the Supply Ditch/(Discharge Through the Supply Ditch-Rate of Infiltration of Soil*Area of Land Strip to be Irrigated)) to evaluate the Time Required to Cover the Given Area With Water, The Approximate Time Required to Cover Area of Land Irrigated with Water formula is defined as close but not the exact time required to cover the irrigated land with water. Time Required to Cover the Given Area With Water is denoted by t symbol.

How to evaluate Approximate Time Required to Cover Area of Land Irrigated with Water using this online evaluator? To use this online evaluator for Approximate Time Required to Cover Area of Land Irrigated with Water, enter Depth of Water Flowing Over the Border Strip (Y), Rate of Infiltration of Soil (f), Discharge Through the Supply Ditch (Q) & Area of Land Strip to be Irrigated (A) and hit the calculate button.

FAQs on Approximate Time Required to Cover Area of Land Irrigated with Water

What is the formula to find Approximate Time Required to Cover Area of Land Irrigated with Water?
The formula of Approximate Time Required to Cover Area of Land Irrigated with Water is expressed as Time Required to Cover the Given Area With Water = 2.3*(Depth of Water Flowing Over the Border Strip/Rate of Infiltration of Soil)*log10(Discharge Through the Supply Ditch/(Discharge Through the Supply Ditch-Rate of Infiltration of Soil*Area of Land Strip to be Irrigated)). Here is an example- 0.650114 = 2.3*(0.1/0.0005)*log10(72/(72-0.0005*400)).
How to calculate Approximate Time Required to Cover Area of Land Irrigated with Water?
With Depth of Water Flowing Over the Border Strip (Y), Rate of Infiltration of Soil (f), Discharge Through the Supply Ditch (Q) & Area of Land Strip to be Irrigated (A) we can find Approximate Time Required to Cover Area of Land Irrigated with Water using the formula - Time Required to Cover the Given Area With Water = 2.3*(Depth of Water Flowing Over the Border Strip/Rate of Infiltration of Soil)*log10(Discharge Through the Supply Ditch/(Discharge Through the Supply Ditch-Rate of Infiltration of Soil*Area of Land Strip to be Irrigated)). This formula also uses Common Logarithm (log10) function(s).
Can the Approximate Time Required to Cover Area of Land Irrigated with Water be negative?
No, the Approximate Time Required to Cover Area of Land Irrigated with Water, measured in Time cannot be negative.
Which unit is used to measure Approximate Time Required to Cover Area of Land Irrigated with Water?
Approximate Time Required to Cover Area of Land Irrigated with Water is usually measured using the Second[s] for Time. Millisecond[s], Microsecond[s], Nanosecond[s] are the few other units in which Approximate Time Required to Cover Area of Land Irrigated with Water can be measured.
Copied!