Phase Difference is defined as the difference between the phasor of apparent and real power (in degrees) or between voltage and current in an ac circuit. Check FAQs
Φ=acos(2PIVm)
Φ - Phase Difference?P - Power Transmitted?I - Current Underground AC?Vm - Maximum Voltage Underground AC?

Angle using Current in Neutral Wire (2-Phase 3-Wire US) Example

With values
With units
Only example

Here is how the Angle using Current in Neutral Wire (2-Phase 3-Wire US) equation looks like with Values.

Here is how the Angle using Current in Neutral Wire (2-Phase 3-Wire US) equation looks like with Units.

Here is how the Angle using Current in Neutral Wire (2-Phase 3-Wire US) equation looks like.

78.1729Edit=acos(2300Edit9Edit230Edit)
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Angle using Current in Neutral Wire (2-Phase 3-Wire US)

Angle using Current in Neutral Wire (2-Phase 3-Wire US) Solution

Follow our step by step solution on how to calculate Angle using Current in Neutral Wire (2-Phase 3-Wire US)?

FIRST Step Consider the formula
Φ=acos(2PIVm)
Next Step Substitute values of Variables
Φ=acos(2300W9A230V)
Next Step Prepare to Evaluate
Φ=acos(23009230)
Next Step Evaluate
Φ=1.36437503282367rad
Next Step Convert to Output's Unit
Φ=78.1729310538342°
LAST Step Rounding Answer
Φ=78.1729°

Angle using Current in Neutral Wire (2-Phase 3-Wire US) Formula Elements

Variables
Functions
Phase Difference
Phase Difference is defined as the difference between the phasor of apparent and real power (in degrees) or between voltage and current in an ac circuit.
Symbol: Φ
Measurement: AngleUnit: °
Note: Value should be greater than 0.
Power Transmitted
Power Transmitted is the amount of power that is transferred from its place of generation to a location where it is applied to perform useful work.
Symbol: P
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Current Underground AC
Current Underground AC is defined as the current flowing through the overhead ac supply wire.
Symbol: I
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.
Maximum Voltage Underground AC
Maximum Voltage Underground AC is defined as the peak amplitude of the AC voltage supplied to the line or wire.
Symbol: Vm
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
cos
Cosine of an angle is the ratio of the side adjacent to the angle to the hypotenuse of the triangle.
Syntax: cos(Angle)
acos
The inverse cosine function, is the inverse function of the cosine function. It is the function that takes a ratio as an input and returns the angle whose cosine is equal to that ratio.
Syntax: acos(Number)
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other Formulas to find Phase Difference

​Go Angle of PF using Volume of Conductor Material (2 Phase 3 Wire US)
Φ=acos((2.914)KV)
​Go Angle of Pf using Line Losses (2-Phase 3-Wire US)
Φ=acos((2+(2PVm))(ρLPlossA))
​Go Angle using Current in Each Outer (2-Phase 3-Wire US)
Φ=acos(PIVm)

Other formulas in Wire Parameters category

​Go Line Losses using Volume of Conductor Material (2 Phase 3 Wire US)
Ploss=((2+2)P)2ρ(L)2(Vmcos(Φ))2V
​Go Length using Volume of Conductor Material (2 Phase 3 Wire US)
L=VPloss(cos(Φ)Vm)2ρ((2+2)P2)
​Go Constant using Volume of Conductor Material (2 Phase 3 Wire US)
K=V(cos(Φ))22.914
​Go Area of X Section using Volume of Conductor Material (2 Phase 3 Wire US)
A=V(2+2)L

How to Evaluate Angle using Current in Neutral Wire (2-Phase 3-Wire US)?

Angle using Current in Neutral Wire (2-Phase 3-Wire US) evaluator uses Phase Difference = acos(sqrt(2)*Power Transmitted/(Current Underground AC*Maximum Voltage Underground AC)) to evaluate the Phase Difference, The Angle using Current in Neutral Wire (2-Phase 3-Wire US) formula is defined as the phase angle between reactive and active power. Phase Difference is denoted by Φ symbol.

How to evaluate Angle using Current in Neutral Wire (2-Phase 3-Wire US) using this online evaluator? To use this online evaluator for Angle using Current in Neutral Wire (2-Phase 3-Wire US), enter Power Transmitted (P), Current Underground AC (I) & Maximum Voltage Underground AC (Vm) and hit the calculate button.

FAQs on Angle using Current in Neutral Wire (2-Phase 3-Wire US)

What is the formula to find Angle using Current in Neutral Wire (2-Phase 3-Wire US)?
The formula of Angle using Current in Neutral Wire (2-Phase 3-Wire US) is expressed as Phase Difference = acos(sqrt(2)*Power Transmitted/(Current Underground AC*Maximum Voltage Underground AC)). Here is an example- 4478.979 = acos(sqrt(2)*300/(9*230)).
How to calculate Angle using Current in Neutral Wire (2-Phase 3-Wire US)?
With Power Transmitted (P), Current Underground AC (I) & Maximum Voltage Underground AC (Vm) we can find Angle using Current in Neutral Wire (2-Phase 3-Wire US) using the formula - Phase Difference = acos(sqrt(2)*Power Transmitted/(Current Underground AC*Maximum Voltage Underground AC)). This formula also uses Cosine (cos)Inverse Cosine (acos), Square Root (sqrt) function(s).
What are the other ways to Calculate Phase Difference?
Here are the different ways to Calculate Phase Difference-
  • Phase Difference=acos(sqrt((2.914)*Constant Underground AC/Volume Of Conductor))OpenImg
  • Phase Difference=acos((2+(sqrt(2)*Power Transmitted/Maximum Voltage Underground AC))*(sqrt(Resistivity*Length of Underground AC Wire/Line Losses*Area of Underground AC Wire)))OpenImg
  • Phase Difference=acos(Power Transmitted/(Current Underground AC*Maximum Voltage Underground AC))OpenImg
Can the Angle using Current in Neutral Wire (2-Phase 3-Wire US) be negative?
No, the Angle using Current in Neutral Wire (2-Phase 3-Wire US), measured in Angle cannot be negative.
Which unit is used to measure Angle using Current in Neutral Wire (2-Phase 3-Wire US)?
Angle using Current in Neutral Wire (2-Phase 3-Wire US) is usually measured using the Degree[°] for Angle. Radian[°], Minute[°], Second[°] are the few other units in which Angle using Current in Neutral Wire (2-Phase 3-Wire US) can be measured.