Ambient Air Humidity based on Wet Bulb Temperature Formula

Fx Copy
LaTeX Copy
Ambient air humidity refers to the moisture content present in the surrounding air at a given location an temperature. Check FAQs
YA=YW'-(hGkY'λW)(TG-TW)
YA - Ambient Air Humidity?YW' - Air Humidity at Wet Bulb Temperature?hG - Heat Transfer Coefficient of the Air Film?kY' - Mass Transfer Coefficient of the Moisture?λW - Heat of Vaporization at Wet Bulb Temperature?TG - Temperature of Air?TW - Wet Bulb Temperature?

Ambient Air Humidity based on Wet Bulb Temperature Example

With values
With units
Only example

Here is how the Ambient Air Humidity based on Wet Bulb Temperature equation looks like with Values.

Here is how the Ambient Air Humidity based on Wet Bulb Temperature equation looks like with Units.

Here is how the Ambient Air Humidity based on Wet Bulb Temperature equation looks like.

0.0157Edit=0.021Edit-(13.32Edit0.01Edit2250Edit)(30Edit-21Edit)
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Mass Transfer Operations » fx Ambient Air Humidity based on Wet Bulb Temperature

Ambient Air Humidity based on Wet Bulb Temperature Solution

Follow our step by step solution on how to calculate Ambient Air Humidity based on Wet Bulb Temperature?

FIRST Step Consider the formula
YA=YW'-(hGkY'λW)(TG-TW)
Next Step Substitute values of Variables
YA=0.021kg/kg of air-(13.32W/m²*K0.01mol/s*m²2250kJ/kg)(30°C-21°C)
Next Step Convert Units
YA=0.021kg/kg of air-(13.32W/m²*K0.01mol/s*m²2.3E+6J/kg)(303.15K-294.15K)
Next Step Prepare to Evaluate
YA=0.021-(13.320.012.3E+6)(303.15-294.15)
Next Step Evaluate
YA=0.015672kg/kg of air
LAST Step Rounding Answer
YA=0.0157kg/kg of air

Ambient Air Humidity based on Wet Bulb Temperature Formula Elements

Variables
Ambient Air Humidity
Ambient air humidity refers to the moisture content present in the surrounding air at a given location an temperature.
Symbol: YA
Measurement: Specific HumidityUnit: kg/kg of air
Note: Value should be greater than 0.
Air Humidity at Wet Bulb Temperature
Air humidity at Wet Bulb Temperature refers to the moisture content present in the surrounding air at a given location at the Wet Bulb temperature.
Symbol: YW'
Measurement: Specific HumidityUnit: kg/kg of air
Note: Value should be greater than 0.
Heat Transfer Coefficient of the Air Film
Heat Transfer Coefficient of the Air Film is the proportionality factor between the heat transfer rate and the temperature driving force.
Symbol: hG
Measurement: Heat Transfer CoefficientUnit: W/m²*K
Note: Value should be greater than 0.
Mass Transfer Coefficient of the Moisture
Mass Transfer Coefficient of the Moisture is the proportionality factor between the mass transfer rate and the concentration driving force.
Symbol: kY'
Measurement: Molar Flux of Diffusing ComponentUnit: mol/s*m²
Note: Value should be greater than 0.
Heat of Vaporization at Wet Bulb Temperature
The heat of vaporization at wet bulb temperature is the energy required per unit mass to convert liquid water into vapor at the wet bulb temperature of the gas liquid mixture.
Symbol: λW
Measurement: Latent HeatUnit: kJ/kg
Note: Value should be greater than 0.
Temperature of Air
The Temperature of Air is defined as the temperature at which the air-water mixture properties in humidification are calculated.
Symbol: TG
Measurement: TemperatureUnit: °C
Note: Value should be greater than -273.15.
Wet Bulb Temperature
Wet bulb temperature is the lowest temperature attainable by evaporating water into air at constant pressure.
Symbol: TW
Measurement: TemperatureUnit: °C
Note: Value should be greater than -273.15.

Other formulas in Adiabatic Saturation Temperature and Wet Bulb Temperature category

​Go Adiabatic Saturation Temperature
TS=TG-(YS'-Y')(λSCs)
​Go Air Inlet Temperature based on Adiabatic Saturation Temperature
TG=(YS'-Y')(λSCs)+TS

How to Evaluate Ambient Air Humidity based on Wet Bulb Temperature?

Ambient Air Humidity based on Wet Bulb Temperature evaluator uses Ambient Air Humidity = Air Humidity at Wet Bulb Temperature-(Heat Transfer Coefficient of the Air Film/(Mass Transfer Coefficient of the Moisture*Heat of Vaporization at Wet Bulb Temperature))*(Temperature of Air-Wet Bulb Temperature) to evaluate the Ambient Air Humidity, The Ambient Air Humidity based on Wet Bulb Temperature formula is defined as the humidity of the ambient air based on its humidity at wet bulb temperature and the heat and mass transfer rates. Ambient Air Humidity is denoted by YA symbol.

How to evaluate Ambient Air Humidity based on Wet Bulb Temperature using this online evaluator? To use this online evaluator for Ambient Air Humidity based on Wet Bulb Temperature, enter Air Humidity at Wet Bulb Temperature (YW'), Heat Transfer Coefficient of the Air Film (hG), Mass Transfer Coefficient of the Moisture (kY'), Heat of Vaporization at Wet Bulb Temperature W), Temperature of Air (TG) & Wet Bulb Temperature (TW) and hit the calculate button.

FAQs on Ambient Air Humidity based on Wet Bulb Temperature

What is the formula to find Ambient Air Humidity based on Wet Bulb Temperature?
The formula of Ambient Air Humidity based on Wet Bulb Temperature is expressed as Ambient Air Humidity = Air Humidity at Wet Bulb Temperature-(Heat Transfer Coefficient of the Air Film/(Mass Transfer Coefficient of the Moisture*Heat of Vaporization at Wet Bulb Temperature))*(Temperature of Air-Wet Bulb Temperature). Here is an example- -5.307 = 0.021-(13.32/(0.01*2250000))*(303.15-294.15).
How to calculate Ambient Air Humidity based on Wet Bulb Temperature?
With Air Humidity at Wet Bulb Temperature (YW'), Heat Transfer Coefficient of the Air Film (hG), Mass Transfer Coefficient of the Moisture (kY'), Heat of Vaporization at Wet Bulb Temperature W), Temperature of Air (TG) & Wet Bulb Temperature (TW) we can find Ambient Air Humidity based on Wet Bulb Temperature using the formula - Ambient Air Humidity = Air Humidity at Wet Bulb Temperature-(Heat Transfer Coefficient of the Air Film/(Mass Transfer Coefficient of the Moisture*Heat of Vaporization at Wet Bulb Temperature))*(Temperature of Air-Wet Bulb Temperature).
Can the Ambient Air Humidity based on Wet Bulb Temperature be negative?
No, the Ambient Air Humidity based on Wet Bulb Temperature, measured in Specific Humidity cannot be negative.
Which unit is used to measure Ambient Air Humidity based on Wet Bulb Temperature?
Ambient Air Humidity based on Wet Bulb Temperature is usually measured using the Kg of water vapour per Kg of air[kg/kg of air] for Specific Humidity. are the few other units in which Ambient Air Humidity based on Wet Bulb Temperature can be measured.
Copied!