Fx Copy
LaTeX Copy
Allowable unit load is the maximum load that can be given on the cross-section or lumber in timber. Check FAQs
Q|A=700(1-0.00000097(Ld)4)
Q|A - Allowable Unit Load?L - Length of Column?d - Least Dimension?

Allowable Unit Load for Hemlock Lumber Example

With values
With units
Only example

Here is how the Allowable Unit Load for Hemlock Lumber equation looks like with Values.

Here is how the Allowable Unit Load for Hemlock Lumber equation looks like with Units.

Here is how the Allowable Unit Load for Hemlock Lumber equation looks like.

434.7656Edit=700(1-0.00000097(5000Edit200Edit)4)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Timber Engineering » fx Allowable Unit Load for Hemlock Lumber

Allowable Unit Load for Hemlock Lumber Solution

Follow our step by step solution on how to calculate Allowable Unit Load for Hemlock Lumber?

FIRST Step Consider the formula
Q|A=700(1-0.00000097(Ld)4)
Next Step Substitute values of Variables
Q|A=700(1-0.00000097(5000mm200mm)4)
Next Step Convert Units
Q|A=700(1-0.00000097(5m0.2m)4)
Next Step Prepare to Evaluate
Q|A=700(1-0.00000097(50.2)4)
Next Step Evaluate
Q|A=434765625Pa
Next Step Convert to Output's Unit
Q|A=434.765625MPa
LAST Step Rounding Answer
Q|A=434.7656MPa

Allowable Unit Load for Hemlock Lumber Formula Elements

Variables
Allowable Unit Load
Allowable unit load is the maximum load that can be given on the cross-section or lumber in timber.
Symbol: Q|A
Measurement: PressureUnit: MPa
Note: Value should be greater than 0.
Length of Column
Length of Column is the distance between two points where a column gets its fixity of support so its movement is restrained in all directions.
Symbol: L
Measurement: LengthUnit: mm
Note: Value should be greater than 0.
Least Dimension
Least Dimension is the measure of the shortest side of the column.
Symbol: d
Measurement: LengthUnit: mm
Note: Value should be greater than 0.

Other Formulas to find Allowable Unit Load

​Go Allowable Unit Load for Longleaf Yellow Pine Lumber
Q|A=1450(1-0.00000162(Ld)4)
​Go Allowable Unit Load for Southern Cypress Lumber
Q|A=1100(1-0.00000168(Ld)4)
​Go Allowable Unit Load for Douglas Fir Lumber
Q|A=1200(1-0.00000112(Ld)4)

How to Evaluate Allowable Unit Load for Hemlock Lumber?

Allowable Unit Load for Hemlock Lumber evaluator uses Allowable Unit Load = 700*(1-0.00000097*(Length of Column/Least Dimension)^4) to evaluate the Allowable Unit Load, The Allowable Unit Load for Hemlock Lumber formula is defined as the maximum allowable load taken by the hemlock lumber cross-section. Allowable Unit Load is denoted by Q|A symbol.

How to evaluate Allowable Unit Load for Hemlock Lumber using this online evaluator? To use this online evaluator for Allowable Unit Load for Hemlock Lumber, enter Length of Column (L) & Least Dimension (d) and hit the calculate button.

FAQs on Allowable Unit Load for Hemlock Lumber

What is the formula to find Allowable Unit Load for Hemlock Lumber?
The formula of Allowable Unit Load for Hemlock Lumber is expressed as Allowable Unit Load = 700*(1-0.00000097*(Length of Column/Least Dimension)^4). Here is an example- 0.000435 = 700*(1-0.00000097*(5/0.2)^4).
How to calculate Allowable Unit Load for Hemlock Lumber?
With Length of Column (L) & Least Dimension (d) we can find Allowable Unit Load for Hemlock Lumber using the formula - Allowable Unit Load = 700*(1-0.00000097*(Length of Column/Least Dimension)^4).
What are the other ways to Calculate Allowable Unit Load?
Here are the different ways to Calculate Allowable Unit Load-
  • Allowable Unit Load=1450*(1-0.00000162*(Length of Column/Least Dimension)^4)OpenImg
  • Allowable Unit Load=1100*(1-0.00000168*(Length of Column/Least Dimension)^4)OpenImg
  • Allowable Unit Load=1200*(1-0.00000112*(Length of Column/Least Dimension)^4)OpenImg
Can the Allowable Unit Load for Hemlock Lumber be negative?
No, the Allowable Unit Load for Hemlock Lumber, measured in Pressure cannot be negative.
Which unit is used to measure Allowable Unit Load for Hemlock Lumber?
Allowable Unit Load for Hemlock Lumber is usually measured using the Megapascal[MPa] for Pressure. Pascal[MPa], Kilopascal[MPa], Bar[MPa] are the few other units in which Allowable Unit Load for Hemlock Lumber can be measured.
Copied!