Allowable Stress given End Zone Reinforcement Formula

Fx Copy
LaTeX Copy
The Allowable Stress is also known as working load and is the ratio of tensile strentgth and factor of safety. Check FAQs
σal=2.5MtAsth
σal - Allowable Stress?Mt - Moment in Structures?Ast - End Zone Reinforcement?h - Total Depth?

Allowable Stress given End Zone Reinforcement Example

With values
With units
Only example

Here is how the Allowable Stress given End Zone Reinforcement equation looks like with Values.

Here is how the Allowable Stress given End Zone Reinforcement equation looks like with Units.

Here is how the Allowable Stress given End Zone Reinforcement equation looks like.

0.0137Edit=2.50.03Edit0.272Edit20.1Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Structural Engineering » fx Allowable Stress given End Zone Reinforcement

Allowable Stress given End Zone Reinforcement Solution

Follow our step by step solution on how to calculate Allowable Stress given End Zone Reinforcement?

FIRST Step Consider the formula
σal=2.5MtAsth
Next Step Substitute values of Variables
σal=2.50.03N*m0.27220.1cm
Next Step Convert Units
σal=2.50.03J0.27220.1cm
Next Step Prepare to Evaluate
σal=2.50.030.27220.1
Next Step Evaluate
σal=0.0137181738366989Pa
Next Step Convert to Output's Unit
σal=0.0137181738366989N/m²
LAST Step Rounding Answer
σal=0.0137N/m²

Allowable Stress given End Zone Reinforcement Formula Elements

Variables
Allowable Stress
The Allowable Stress is also known as working load and is the ratio of tensile strentgth and factor of safety.
Symbol: σal
Measurement: PressureUnit: N/m²
Note: Value should be greater than 0.
Moment in Structures
The Moment in Structures is an overturning effect (tends to bend or turn the member) created by the force(load) acting on a structural member.
Symbol: Mt
Measurement: EnergyUnit: N*m
Note: Value should be greater than 0.
End Zone Reinforcement
End Zone Reinforcement can be defined as the reinforcement which restrict the splitting of concrete, in addition to shear reinforcement, provided at each ends of member.
Symbol: Ast
Measurement: AreaUnit:
Note: Value should be greater than 0.
Total Depth
Total Depth is described as the total depth of the member.
Symbol: h
Measurement: LengthUnit: cm
Note: Value should be greater than 0.

Other formulas in Post Tensioned Members category

​Go End Zone Reinforcement along Transmission Length
Ast=2.5Mtσalh
​Go Bursting Force for Square End Zone
Fbst=F(0.32-0.3(YpoYo))
​Go Prestress in Tendon given Bursting Force for Square End Zone
F=Fbst0.32-0.3(YpoYo)
​Go Length of Side of Bearing Plate given Bursting Force for Square End Zone
Ypo=-((FbstF)-0.320.3)Yo

How to Evaluate Allowable Stress given End Zone Reinforcement?

Allowable Stress given End Zone Reinforcement evaluator uses Allowable Stress = (2.5*Moment in Structures)/(End Zone Reinforcement*Total Depth) to evaluate the Allowable Stress, The Allowable Stress given End Zone Reinforcement formula is defined as the maximum stress that can be safely applied to structure. Allowable Stress is denoted by σal symbol.

How to evaluate Allowable Stress given End Zone Reinforcement using this online evaluator? To use this online evaluator for Allowable Stress given End Zone Reinforcement, enter Moment in Structures (Mt), End Zone Reinforcement (Ast) & Total Depth (h) and hit the calculate button.

FAQs on Allowable Stress given End Zone Reinforcement

What is the formula to find Allowable Stress given End Zone Reinforcement?
The formula of Allowable Stress given End Zone Reinforcement is expressed as Allowable Stress = (2.5*Moment in Structures)/(End Zone Reinforcement*Total Depth). Here is an example- 26.97908 = (2.5*0.03)/(0.272*0.201).
How to calculate Allowable Stress given End Zone Reinforcement?
With Moment in Structures (Mt), End Zone Reinforcement (Ast) & Total Depth (h) we can find Allowable Stress given End Zone Reinforcement using the formula - Allowable Stress = (2.5*Moment in Structures)/(End Zone Reinforcement*Total Depth).
Can the Allowable Stress given End Zone Reinforcement be negative?
No, the Allowable Stress given End Zone Reinforcement, measured in Pressure cannot be negative.
Which unit is used to measure Allowable Stress given End Zone Reinforcement?
Allowable Stress given End Zone Reinforcement is usually measured using the Newton per Square Meter[N/m²] for Pressure. Pascal[N/m²], Kilopascal[N/m²], Bar[N/m²] are the few other units in which Allowable Stress given End Zone Reinforcement can be measured.
Copied!