Fx Copy
LaTeX Copy
Total Allowable Load for Nails or Spikes is the capacity or can say the maximum load allowed. Check FAQs
Pnails=1380(G52)Dspikes
Pnails - Total Allowable Load for Nails or Spikes?G - Specific Gravity of Wood Oven Dry?Dspikes - Diameter of Spike or Nail?

Allowable Load per Inch of Penetration into Member Receiving Point Example

With values
With units
Only example

Here is how the Allowable Load per Inch of Penetration into Member Receiving Point equation looks like with Values.

Here is how the Allowable Load per Inch of Penetration into Member Receiving Point equation looks like with Units.

Here is how the Allowable Load per Inch of Penetration into Member Receiving Point equation looks like.

2.4944Edit=1380(0.265Edit52)50Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Timber Engineering » fx Allowable Load per Inch of Penetration into Member Receiving Point

Allowable Load per Inch of Penetration into Member Receiving Point Solution

Follow our step by step solution on how to calculate Allowable Load per Inch of Penetration into Member Receiving Point?

FIRST Step Consider the formula
Pnails=1380(G52)Dspikes
Next Step Substitute values of Variables
Pnails=1380(0.26552)50mm
Next Step Convert Units
Pnails=1380(0.26552)0.05m
Next Step Prepare to Evaluate
Pnails=1380(0.26552)0.05
Next Step Evaluate
Pnails=2.49438716082263N
LAST Step Rounding Answer
Pnails=2.4944N

Allowable Load per Inch of Penetration into Member Receiving Point Formula Elements

Variables
Total Allowable Load for Nails or Spikes
Total Allowable Load for Nails or Spikes is the capacity or can say the maximum load allowed.
Symbol: Pnails
Measurement: ForceUnit: N
Note: Value should be greater than 0.
Specific Gravity of Wood Oven Dry
Specific gravity of wood oven dry, Specific gravity is the ratio of the density of a substance to the density of a given reference material.
Symbol: G
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Diameter of Spike or Nail
Diameter of Spike or Nail in mm are pieces of soft iron or steel or other materials of variable lengths and thicknesses, pointed at one end and with a head at the other serving to join pieces.
Symbol: Dspikes
Measurement: LengthUnit: mm
Note: Value should be greater than 0.

Other Formulas to find Total Allowable Load for Nails or Spikes

​Go Total Allowable Lateral Load for Nail or Spike
Pnails=C(Dspikes)32

Other formulas in Nails and Spikes category

​Go Diameter of Nail or Spike given Allowable Load per Inch of Penetration
Dspikes=Pnails1380(G)52

How to Evaluate Allowable Load per Inch of Penetration into Member Receiving Point?

Allowable Load per Inch of Penetration into Member Receiving Point evaluator uses Total Allowable Load for Nails or Spikes = 1380*(Specific Gravity of Wood Oven Dry^(5/2))*Diameter of Spike or Nail to evaluate the Total Allowable Load for Nails or Spikes, Allowable Load per Inch of Penetration into Member Receiving Point is defined by the parameters specific gravity of wood, oven dry and diameter of nail or spike. Total Allowable Load for Nails or Spikes is denoted by Pnails symbol.

How to evaluate Allowable Load per Inch of Penetration into Member Receiving Point using this online evaluator? To use this online evaluator for Allowable Load per Inch of Penetration into Member Receiving Point, enter Specific Gravity of Wood Oven Dry (G) & Diameter of Spike or Nail (Dspikes) and hit the calculate button.

FAQs on Allowable Load per Inch of Penetration into Member Receiving Point

What is the formula to find Allowable Load per Inch of Penetration into Member Receiving Point?
The formula of Allowable Load per Inch of Penetration into Member Receiving Point is expressed as Total Allowable Load for Nails or Spikes = 1380*(Specific Gravity of Wood Oven Dry^(5/2))*Diameter of Spike or Nail. Here is an example- 2.494387 = 1380*(0.265^(5/2))*0.05000001.
How to calculate Allowable Load per Inch of Penetration into Member Receiving Point?
With Specific Gravity of Wood Oven Dry (G) & Diameter of Spike or Nail (Dspikes) we can find Allowable Load per Inch of Penetration into Member Receiving Point using the formula - Total Allowable Load for Nails or Spikes = 1380*(Specific Gravity of Wood Oven Dry^(5/2))*Diameter of Spike or Nail.
What are the other ways to Calculate Total Allowable Load for Nails or Spikes?
Here are the different ways to Calculate Total Allowable Load for Nails or Spikes-
  • Total Allowable Load for Nails or Spikes=Coefficient Dependent on Group Number of Wood*(Diameter of Spike or Nail)^(3/2)OpenImg
Can the Allowable Load per Inch of Penetration into Member Receiving Point be negative?
No, the Allowable Load per Inch of Penetration into Member Receiving Point, measured in Force cannot be negative.
Which unit is used to measure Allowable Load per Inch of Penetration into Member Receiving Point?
Allowable Load per Inch of Penetration into Member Receiving Point is usually measured using the Newton[N] for Force. Exanewton[N], Meganewton[N], Kilonewton[N] are the few other units in which Allowable Load per Inch of Penetration into Member Receiving Point can be measured.