Air infiltration rate into room (CFM) Formula

Fx Copy
LaTeX Copy
Air Infiltration Rate into Room is the volumetric flow rate of outside air into a building/room. Check FAQs
CFM=ACH(V60)
CFM - Air Infiltration Rate into Room?ACH - Number of Air Changes Per Hour?V - Room Volume?

Air infiltration rate into room (CFM) Example

With values
With units
Only example

Here is how the Air infiltration rate into room (CFM) equation looks like with Values.

Here is how the Air infiltration rate into room (CFM) equation looks like with Units.

Here is how the Air infiltration rate into room (CFM) equation looks like.

6400Edit=16Edit(400Edit60)
You are here -
HomeIcon Home » Category Physics » Category Mechanical » Category Refrigeration and Air Conditioning » fx Air infiltration rate into room (CFM)

Air infiltration rate into room (CFM) Solution

Follow our step by step solution on how to calculate Air infiltration rate into room (CFM)?

FIRST Step Consider the formula
CFM=ACH(V60)
Next Step Substitute values of Variables
CFM=16(400ft³60)
Next Step Convert Units
CFM=16(11.326760)
Next Step Prepare to Evaluate
CFM=16(11.326760)
Next Step Evaluate
CFM=3.02046363651624m³/s
Next Step Convert to Output's Unit
CFM=6399.99999999999ft³/min
LAST Step Rounding Answer
CFM=6400ft³/min

Air infiltration rate into room (CFM) Formula Elements

Variables
Air Infiltration Rate into Room
Air Infiltration Rate into Room is the volumetric flow rate of outside air into a building/room.
Symbol: CFM
Measurement: Volumetric Flow RateUnit: ft³/min
Note: Value can be positive or negative.
Number of Air Changes Per Hour
Number of air changes per hour is a measure of the air volume added to or removed from a space in one hour, divided by the volume of the space.
Symbol: ACH
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Room Volume
Room volume is volume of the conditioned space under study or under consideration.
Symbol: V
Measurement: VolumeUnit: ft³
Note: Value can be positive or negative.

Other formulas in Cooling Loads category

​Go Cooling load for roof, wall or glass given Corrected Cooling Load Temperature Difference
Q=UoArCLTDc
​Go Corrected Cooling Load Temperature Difference given Cooling Load Temperature Difference
CLTDc=CLΔt+LM+(78-tr)+(ta-85)
​Go Average outside temperature on design day
to=tod-(DR2)
​Go Total heat removed from ventilation air
Qt=Qs+Qlv

How to Evaluate Air infiltration rate into room (CFM)?

Air infiltration rate into room (CFM) evaluator uses Air Infiltration Rate into Room = Number of Air Changes Per Hour*(Room Volume/60) to evaluate the Air Infiltration Rate into Room, Air infiltration rate into room (CFM) formula is defined as the measure of the flow rate of outdoor air that infiltrates into a room through cracks, crevices, and other openings, typically measured in cubic feet per minute, which affects the indoor air quality and building energy efficiency. Air Infiltration Rate into Room is denoted by CFM symbol.

How to evaluate Air infiltration rate into room (CFM) using this online evaluator? To use this online evaluator for Air infiltration rate into room (CFM), enter Number of Air Changes Per Hour (ACH) & Room Volume (V) and hit the calculate button.

FAQs on Air infiltration rate into room (CFM)

What is the formula to find Air infiltration rate into room (CFM)?
The formula of Air infiltration rate into room (CFM) is expressed as Air Infiltration Rate into Room = Number of Air Changes Per Hour*(Room Volume/60). Here is an example- 1.4E+7 = 16*(11.3267386369359/60).
How to calculate Air infiltration rate into room (CFM)?
With Number of Air Changes Per Hour (ACH) & Room Volume (V) we can find Air infiltration rate into room (CFM) using the formula - Air Infiltration Rate into Room = Number of Air Changes Per Hour*(Room Volume/60).
Can the Air infiltration rate into room (CFM) be negative?
Yes, the Air infiltration rate into room (CFM), measured in Volumetric Flow Rate can be negative.
Which unit is used to measure Air infiltration rate into room (CFM)?
Air infiltration rate into room (CFM) is usually measured using the Cubic Foot per Minute[ft³/min] for Volumetric Flow Rate. Cubic Meter per Second[ft³/min], Cubic Meter per Day[ft³/min], Cubic Meter per Hour[ft³/min] are the few other units in which Air infiltration rate into room (CFM) can be measured.
Copied!