Agression Driver Formula

Fx Copy
LaTeX Copy
Agression Driver is defined as the resistance experienced by the voltage around the agression driver. Check FAQs
Ragr=Rvik(Cadj+Cgnd)Cga+Cadj
Ragr - Agression Driver?Rvi - Victim Driver?k - Time Constant Ratio?Cadj - Adjacent Capacitance?Cgnd - Ground Capacitance?Cga - Ground A Capacitance?

Agression Driver Example

With values
With units
Only example

Here is how the Agression Driver equation looks like with Values.

Here is how the Agression Driver equation looks like with Units.

Here is how the Agression Driver equation looks like.

1.1233Edit=1.98Edit0.62Edit(8Edit+2.98Edit)4Edit+8Edit
You are here -
HomeIcon Home » Category Engineering » Category Electronics » Category CMOS Design and Applications » fx Agression Driver

Agression Driver Solution

Follow our step by step solution on how to calculate Agression Driver?

FIRST Step Consider the formula
Ragr=Rvik(Cadj+Cgnd)Cga+Cadj
Next Step Substitute values of Variables
Ragr=1.980.62(8pF+2.98pF)4pF+8pF
Next Step Convert Units
Ragr=1.980.62(8E-12F+3E-12F)4E-12F+8E-12F
Next Step Prepare to Evaluate
Ragr=1.980.62(8E-12+3E-12)4E-12+8E-12
Next Step Evaluate
Ragr=1.123254
LAST Step Rounding Answer
Ragr=1.1233

Agression Driver Formula Elements

Variables
Agression Driver
Agression Driver is defined as the resistance experienced by the voltage around the agression driver.
Symbol: Ragr
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Victim Driver
Victim Driver refers to a type of electronic component that acts as an amplifier or attenuator to amplify or reduce the input signal.
Symbol: Rvi
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Time Constant Ratio
Time Constant Ratio is defined as the parameter characterizing the response to a step input of a first-order, linear time-invariant (LTI) system.
Symbol: k
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Adjacent Capacitance
Adjacent capacitance is the capacitance at adjacent point.
Symbol: Cadj
Measurement: CapacitanceUnit: pF
Note: Value should be greater than 0.
Ground Capacitance
Ground Capacitance is the capacitance at the ground of the CMOS Circuit.
Symbol: Cgnd
Measurement: CapacitanceUnit: pF
Note: Value should be greater than 0.
Ground A Capacitance
Ground A Capacitance is a measure of the ability of a grounding system to dissipate charge. It is defined as the ratio of the charge stored in the ground to the resulting voltage change.
Symbol: Cga
Measurement: CapacitanceUnit: pF
Note: Value should be greater than 0.

Other formulas in CMOS Design Characteristics category

​Go Static Current
istatic=PstaticVbc
​Go Built-in Potential
ψo=Vtln(NaNdni2)
​Go Change in Frequency Clock
Δf=KvcoVctrl
​Go Capacitance Onpath
Conpath=Ct-Coffpath

How to Evaluate Agression Driver?

Agression Driver evaluator uses Agression Driver = (Victim Driver*Time Constant Ratio*(Adjacent Capacitance+Ground Capacitance))/(Ground A Capacitance+Adjacent Capacitance) to evaluate the Agression Driver, The Agression Driver formula is defined as the resistance experienced by the the voltage around the Agression Driver. Agression Driver is denoted by Ragr symbol.

How to evaluate Agression Driver using this online evaluator? To use this online evaluator for Agression Driver, enter Victim Driver (Rvi), Time Constant Ratio (k), Adjacent Capacitance (Cadj), Ground Capacitance (Cgnd) & Ground A Capacitance (Cga) and hit the calculate button.

FAQs on Agression Driver

What is the formula to find Agression Driver?
The formula of Agression Driver is expressed as Agression Driver = (Victim Driver*Time Constant Ratio*(Adjacent Capacitance+Ground Capacitance))/(Ground A Capacitance+Adjacent Capacitance). Here is an example- 1.1253 = (1.98*0.62*(8E-12+2.98E-12))/(4E-12+8E-12).
How to calculate Agression Driver?
With Victim Driver (Rvi), Time Constant Ratio (k), Adjacent Capacitance (Cadj), Ground Capacitance (Cgnd) & Ground A Capacitance (Cga) we can find Agression Driver using the formula - Agression Driver = (Victim Driver*Time Constant Ratio*(Adjacent Capacitance+Ground Capacitance))/(Ground A Capacitance+Adjacent Capacitance).
Copied!