Fx Copy
LaTeX Copy
Adjusted design value for lateral loading is given in terms of nominal design values and adjustment factors. Check FAQs
Z'=ZCDCmCtCegCdCdiCtn
Z' - Adjusted Design Value for Lateral Loading?Z - Nominal Design Value for Lateral Loading?CD - Load Duration Factor?Cm - Wet Service Factor?Ct - Temperature Factor?Ceg - End Grain Factor?Cd - Penetration Depth Factor?Cdi - Diaphragm Factor?Ctn - Toenail Factor?

Adjusted Design Value for Lateral Loading for Nails and Spikes Example

With values
With units
Only example

Here is how the Adjusted Design Value for Lateral Loading for Nails and Spikes equation looks like with Values.

Here is how the Adjusted Design Value for Lateral Loading for Nails and Spikes equation looks like with Units.

Here is how the Adjusted Design Value for Lateral Loading for Nails and Spikes equation looks like.

3.7611Edit=20Edit0.74Edit0.81Edit0.8Edit0.75Edit0.9Edit0.7Edit0.83Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Timber Engineering » fx Adjusted Design Value for Lateral Loading for Nails and Spikes

Adjusted Design Value for Lateral Loading for Nails and Spikes Solution

Follow our step by step solution on how to calculate Adjusted Design Value for Lateral Loading for Nails and Spikes?

FIRST Step Consider the formula
Z'=ZCDCmCtCegCdCdiCtn
Next Step Substitute values of Variables
Z'=20N0.740.810.80.750.90.70.83
Next Step Prepare to Evaluate
Z'=200.740.810.80.750.90.70.83
Next Step Evaluate
Z'=3.76111512N
LAST Step Rounding Answer
Z'=3.7611N

Adjusted Design Value for Lateral Loading for Nails and Spikes Formula Elements

Variables
Adjusted Design Value for Lateral Loading
Adjusted design value for lateral loading is given in terms of nominal design values and adjustment factors.
Symbol: Z'
Measurement: ForceUnit: N
Note: Value should be greater than 0.
Nominal Design Value for Lateral Loading
Nominal Design Value for Lateral Loading for connections or wood members with fasteners. Design values are principles or beliefs that are adopted by a designer to guide their work.
Symbol: Z
Measurement: ForceUnit: N
Note: Value should be greater than 0.
Load Duration Factor
Load Duration Factor is based on the ability of wood to recover after a reasonable load has been applied for a given time.
Symbol: CD
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Wet Service Factor
Wet Service Factor is used to signify wood that will not be used in a dry condition.
Symbol: Cm
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Temperature Factor
Temperature factor is the factor used for wood that is expected to be exposed to high temperatures for long periods of time.
Symbol: Ct
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
End Grain Factor
End Grain Factor is a factor used for wood design. End grain is the grain of wood seen when it is cut across the growth rings.
Symbol: Ceg
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Penetration Depth Factor
Penetration Depth Factor for split ring and shear plate connectors is the analyzing area for resistivity measurement depends on several factors of the material. In no case should Cd exceed unity.
Symbol: Cd
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Diaphragm Factor
Diaphragm Factor is the adjustment factor used in finding the design value for lateral loading for nails and spikes.
Symbol: Cdi
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Toenail Factor
Toenail Factor is the adjustment factor used for wood design.
Symbol: Ctn
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.

Other Formulas to find Adjusted Design Value for Lateral Loading

​Go Adjusted Design Value for Lateral Loading for Bolts
Z'=ZC'DCmCtCgCΔ
​Go Adjusted Design Value for Lateral Loading for Wood Screws
Z'=ZCDCmCtCegCd

Other formulas in Adjustment of Design Values for Connections with Fasteners category

​Go Adjusted Value for Loading Parallel to Grain for Split Ring and Shear Plate Connectors
P'=PC'DCmCtCgCΔCdCst
​Go Adjusted Value for Loading Normal to Grain for Split Ring and Shear Plate Connectors
Q'=QC'DCmCtCgCΔCd

How to Evaluate Adjusted Design Value for Lateral Loading for Nails and Spikes?

Adjusted Design Value for Lateral Loading for Nails and Spikes evaluator uses Adjusted Design Value for Lateral Loading = Nominal Design Value for Lateral Loading*Load Duration Factor*Wet Service Factor*Temperature Factor*End Grain Factor*Penetration Depth Factor*Diaphragm Factor*Toenail Factor to evaluate the Adjusted Design Value for Lateral Loading, The Adjusted Design Value for Lateral Loading for Nails and Spikes formula is defined as the design value which is the product of the nominal design value of lateral loads and adjustment factors for nails and spikes. Adjusted Design Value for Lateral Loading is denoted by Z' symbol.

How to evaluate Adjusted Design Value for Lateral Loading for Nails and Spikes using this online evaluator? To use this online evaluator for Adjusted Design Value for Lateral Loading for Nails and Spikes, enter Nominal Design Value for Lateral Loading (Z), Load Duration Factor (CD), Wet Service Factor (Cm), Temperature Factor (Ct), End Grain Factor (Ceg), Penetration Depth Factor (Cd), Diaphragm Factor (Cdi) & Toenail Factor (Ctn) and hit the calculate button.

FAQs on Adjusted Design Value for Lateral Loading for Nails and Spikes

What is the formula to find Adjusted Design Value for Lateral Loading for Nails and Spikes?
The formula of Adjusted Design Value for Lateral Loading for Nails and Spikes is expressed as Adjusted Design Value for Lateral Loading = Nominal Design Value for Lateral Loading*Load Duration Factor*Wet Service Factor*Temperature Factor*End Grain Factor*Penetration Depth Factor*Diaphragm Factor*Toenail Factor. Here is an example- 3.761115 = 20*0.74*0.81*0.8*0.75*0.9*0.7*0.83.
How to calculate Adjusted Design Value for Lateral Loading for Nails and Spikes?
With Nominal Design Value for Lateral Loading (Z), Load Duration Factor (CD), Wet Service Factor (Cm), Temperature Factor (Ct), End Grain Factor (Ceg), Penetration Depth Factor (Cd), Diaphragm Factor (Cdi) & Toenail Factor (Ctn) we can find Adjusted Design Value for Lateral Loading for Nails and Spikes using the formula - Adjusted Design Value for Lateral Loading = Nominal Design Value for Lateral Loading*Load Duration Factor*Wet Service Factor*Temperature Factor*End Grain Factor*Penetration Depth Factor*Diaphragm Factor*Toenail Factor.
What are the other ways to Calculate Adjusted Design Value for Lateral Loading?
Here are the different ways to Calculate Adjusted Design Value for Lateral Loading-
  • Adjusted Design Value for Lateral Loading=Nominal Design Value for Lateral Loading*Load Duration Factor for Bolts*Wet Service Factor*Temperature Factor*Group Action Factor*Geometry FactorOpenImg
  • Adjusted Design Value for Lateral Loading=Nominal Design Value for Lateral Loading*Load Duration Factor*Wet Service Factor*Temperature Factor*End Grain Factor*Penetration Depth FactorOpenImg
  • Adjusted Design Value for Lateral Loading=Nominal Design Value for Lateral Loading*Wet Service Factor*Load Duration Factor*Temperature Factor*Penetration Depth Factor*End Grain Factor*Group Action Factor*Geometry FactorOpenImg
Can the Adjusted Design Value for Lateral Loading for Nails and Spikes be negative?
No, the Adjusted Design Value for Lateral Loading for Nails and Spikes, measured in Force cannot be negative.
Which unit is used to measure Adjusted Design Value for Lateral Loading for Nails and Spikes?
Adjusted Design Value for Lateral Loading for Nails and Spikes is usually measured using the Newton[N] for Force. Exanewton[N], Meganewton[N], Kilonewton[N] are the few other units in which Adjusted Design Value for Lateral Loading for Nails and Spikes can be measured.
Copied!