Fx Copy
LaTeX Copy
Adiabatic wall enthalpy, is the Enthalpy of a fluid flowing around a solid body; it corresponds to the adiabatic wall temperature. Check FAQs
haw=he+r(h0-he)
haw - Adiabatic Wall Enthalpy?he - Static Enthalpy?r - Recovery Factor?h0 - Total Specific Enthalpy?

Adiabatic Wall Enthalpy for Flat Plate Example

With values
With units
Only example

Here is how the Adiabatic Wall Enthalpy for Flat Plate equation looks like with Values.

Here is how the Adiabatic Wall Enthalpy for Flat Plate equation looks like with Units.

Here is how the Adiabatic Wall Enthalpy for Flat Plate equation looks like.

472Edit=40Edit+2.7Edit(200Edit-40Edit)
You are here -
HomeIcon Home » Category Engineering » Category Mechanical » Category Fluid Mechanics » fx Adiabatic Wall Enthalpy for Flat Plate

Adiabatic Wall Enthalpy for Flat Plate Solution

Follow our step by step solution on how to calculate Adiabatic Wall Enthalpy for Flat Plate?

FIRST Step Consider the formula
haw=he+r(h0-he)
Next Step Substitute values of Variables
haw=40J/kg+2.7(200J/kg-40J/kg)
Next Step Prepare to Evaluate
haw=40+2.7(200-40)
LAST Step Evaluate
haw=472J/kg

Adiabatic Wall Enthalpy for Flat Plate Formula Elements

Variables
Adiabatic Wall Enthalpy
Adiabatic wall enthalpy, is the Enthalpy of a fluid flowing around a solid body; it corresponds to the adiabatic wall temperature.
Symbol: haw
Measurement: Specific EnergyUnit: J/kg
Note: Value should be greater than 0.
Static Enthalpy
Static Enthalpy is the constant enthalpy of the fluid.
Symbol: he
Measurement: Specific EnergyUnit: J/kg
Note: Value should be greater than 0.
Recovery Factor
Recovery Factor is a dimensionless number defined by the ratio of difference in enthalpies.
Symbol: r
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Total Specific Enthalpy
Total Specific Enthalpy defined to be the sum of the internal energy E plus the product of the pressure p and volume V.
Symbol: h0
Measurement: Specific EnergyUnit: J/kg
Note: Value should be greater than 0.

Other Formulas to find Adiabatic Wall Enthalpy

​Go Adiabatic Wall Enthalpy using Recovery Factor
haw=he+rue22

Other formulas in Viscous Flow category

​Go Aerodynamic Heating Equation for Stanton number
St=qwρeue(haw-hw)
​Go Coefficient of Friction using Stanton Number for Flat Plate Case
μfriction=2StPr-23
​Go Drag per Unit Span
FD=0.86qxLRe
​Go Prandtl Number for Flat Plate with Viscous Flow
Pr=r2

How to Evaluate Adiabatic Wall Enthalpy for Flat Plate?

Adiabatic Wall Enthalpy for Flat Plate evaluator uses Adiabatic Wall Enthalpy = Static Enthalpy+Recovery Factor*(Total Specific Enthalpy-Static Enthalpy) to evaluate the Adiabatic Wall Enthalpy, The Adiabatic wall enthalpy for flat plate formula is defined as the function of static enthalpy, recovery factor and total enthalpy. Adiabatic Wall Enthalpy is denoted by haw symbol.

How to evaluate Adiabatic Wall Enthalpy for Flat Plate using this online evaluator? To use this online evaluator for Adiabatic Wall Enthalpy for Flat Plate, enter Static Enthalpy (he), Recovery Factor (r) & Total Specific Enthalpy (h0) and hit the calculate button.

FAQs on Adiabatic Wall Enthalpy for Flat Plate

What is the formula to find Adiabatic Wall Enthalpy for Flat Plate?
The formula of Adiabatic Wall Enthalpy for Flat Plate is expressed as Adiabatic Wall Enthalpy = Static Enthalpy+Recovery Factor*(Total Specific Enthalpy-Static Enthalpy). Here is an example- 472 = 40+2.7*(200-40).
How to calculate Adiabatic Wall Enthalpy for Flat Plate?
With Static Enthalpy (he), Recovery Factor (r) & Total Specific Enthalpy (h0) we can find Adiabatic Wall Enthalpy for Flat Plate using the formula - Adiabatic Wall Enthalpy = Static Enthalpy+Recovery Factor*(Total Specific Enthalpy-Static Enthalpy).
What are the other ways to Calculate Adiabatic Wall Enthalpy?
Here are the different ways to Calculate Adiabatic Wall Enthalpy-
  • Adiabatic Wall Enthalpy=Static Enthalpy+Recovery Factor*(Static Velocity^2)/2OpenImg
Can the Adiabatic Wall Enthalpy for Flat Plate be negative?
No, the Adiabatic Wall Enthalpy for Flat Plate, measured in Specific Energy cannot be negative.
Which unit is used to measure Adiabatic Wall Enthalpy for Flat Plate?
Adiabatic Wall Enthalpy for Flat Plate is usually measured using the Joule per Kilogram[J/kg] for Specific Energy. Joule per Gram[J/kg], Joule per Centigram[J/kg], Square Meter per Square Second[J/kg] are the few other units in which Adiabatic Wall Enthalpy for Flat Plate can be measured.
Copied!