Fx Copy
LaTeX Copy
Volume of Real Gas given CP is the space occupied by that real gas at standard temperature and pressure. Check FAQs
Vreal_CP=((3[R]Tc8P'c)-c)V'm,r
Vreal_CP - Volume of Real Gas given CP?Tc - Critical Temperature?P'c - Critical Pressure of Real Gas?c - Clausius Parameter c?V'm,r - Reduced Molar Volume for Real Gas?[R] - Universal gas constant?

Actual Volume of Real Gas using Clausius Parameter c, Reduced and Critical Parameters Example

With values
With units
Only example

Here is how the Actual Volume of Real Gas using Clausius Parameter c, Reduced and Critical Parameters equation looks like with Values.

Here is how the Actual Volume of Real Gas using Clausius Parameter c, Reduced and Critical Parameters equation looks like with Units.

Here is how the Actual Volume of Real Gas using Clausius Parameter c, Reduced and Critical Parameters equation looks like.

2.1373Edit=((38.3145647Edit84.6E+6Edit)-0.0002Edit)8.96Edit
You are here -
HomeIcon Home » Category Chemistry » Category Kinetic Theory of Gases » Category Real Gas » fx Actual Volume of Real Gas using Clausius Parameter c, Reduced and Critical Parameters

Actual Volume of Real Gas using Clausius Parameter c, Reduced and Critical Parameters Solution

Follow our step by step solution on how to calculate Actual Volume of Real Gas using Clausius Parameter c, Reduced and Critical Parameters?

FIRST Step Consider the formula
Vreal_CP=((3[R]Tc8P'c)-c)V'm,r
Next Step Substitute values of Variables
Vreal_CP=((3[R]647K84.6E+6Pa)-0.0002)8.96
Next Step Substitute values of Constants
Vreal_CP=((38.3145647K84.6E+6Pa)-0.0002)8.96
Next Step Prepare to Evaluate
Vreal_CP=((38.314564784.6E+6)-0.0002)8.96
Next Step Evaluate
Vreal_CP=0.00213734273366428
Next Step Convert to Output's Unit
Vreal_CP=2.13734273366428L
LAST Step Rounding Answer
Vreal_CP=2.1373L

Actual Volume of Real Gas using Clausius Parameter c, Reduced and Critical Parameters Formula Elements

Variables
Constants
Volume of Real Gas given CP
Volume of Real Gas given CP is the space occupied by that real gas at standard temperature and pressure.
Symbol: Vreal_CP
Measurement: VolumeUnit: L
Note: Value can be positive or negative.
Critical Temperature
Critical Temperature is the highest temperature at which the substance can exist as a liquid. At this phase boundaries vanish, and the substance can exist both as a liquid and vapor.
Symbol: Tc
Measurement: TemperatureUnit: K
Note: Value should be greater than 0.
Critical Pressure of Real Gas
Critical Pressure of Real Gas is the minimum pressure required to liquify a substance at the critical temperature.
Symbol: P'c
Measurement: PressureUnit: Pa
Note: Value should be greater than 0.
Clausius Parameter c
Clausius parameter c is an empirical parameter characteristic to equation obtained from Clausius model of real gas.
Symbol: c
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Reduced Molar Volume for Real Gas
Reduced Molar Volume for Real Gas of a fluid is computed from the ideal gas law at the substance's critical pressure and temperature per mole.
Symbol: V'm,r
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Universal gas constant
Universal gas constant is a fundamental physical constant that appears in the ideal gas law, relating the pressure, volume, and temperature of an ideal gas.
Symbol: [R]
Value: 8.31446261815324

Other Formulas to find Volume of Real Gas given CP

​Go Actual Volume of Real Gas using Clausius Parameter b, Reduced and Critical Parameters
Vreal_CP=(b'+([R]T'c4P'c))Vr

Other formulas in Actual Volume of Real Gas category

​Go Actual Pressure of Real Gas given Clausius Parameter a, Reduced and Critical Parameters
Pa=(27([R]2)(T'c3)64a)Pr
​Go Actual Pressure of Real Gas given Clausius Parameter b, Reduced and Actual Parameters
Pb=([R](TrgTr)4((VrealVr)-b'))Pr
​Go Actual Pressure of Real Gas given Clausius Parameter c, Reduced and Actual Parameters
Pc=(3[R](TrgTr)8(c+(VrealVr)))Pr
​Go Actual Temperature of Real Gas given Clausius Parameter a, Reduced and Actual Parameters
TRP=((a64(pPr)27([R]2))13)Tr

How to Evaluate Actual Volume of Real Gas using Clausius Parameter c, Reduced and Critical Parameters?

Actual Volume of Real Gas using Clausius Parameter c, Reduced and Critical Parameters evaluator uses Volume of Real Gas given CP = (((3*[R]*Critical Temperature)/(8*Critical Pressure of Real Gas))-Clausius Parameter c)*Reduced Molar Volume for Real Gas to evaluate the Volume of Real Gas given CP, The Actual Volume of Real Gas using Clausius Parameter c, Reduced and Critical Parameters formula is defined as the physical force exerted on the walls of the container by a real gas. Volume of Real Gas given CP is denoted by Vreal_CP symbol.

How to evaluate Actual Volume of Real Gas using Clausius Parameter c, Reduced and Critical Parameters using this online evaluator? To use this online evaluator for Actual Volume of Real Gas using Clausius Parameter c, Reduced and Critical Parameters, enter Critical Temperature (Tc), Critical Pressure of Real Gas (P'c), Clausius Parameter c (c) & Reduced Molar Volume for Real Gas (V'm,r) and hit the calculate button.

FAQs on Actual Volume of Real Gas using Clausius Parameter c, Reduced and Critical Parameters

What is the formula to find Actual Volume of Real Gas using Clausius Parameter c, Reduced and Critical Parameters?
The formula of Actual Volume of Real Gas using Clausius Parameter c, Reduced and Critical Parameters is expressed as Volume of Real Gas given CP = (((3*[R]*Critical Temperature)/(8*Critical Pressure of Real Gas))-Clausius Parameter c)*Reduced Molar Volume for Real Gas. Here is an example- 2137.343 = (((3*[R]*647)/(8*4600000))-0.0002)*8.96.
How to calculate Actual Volume of Real Gas using Clausius Parameter c, Reduced and Critical Parameters?
With Critical Temperature (Tc), Critical Pressure of Real Gas (P'c), Clausius Parameter c (c) & Reduced Molar Volume for Real Gas (V'm,r) we can find Actual Volume of Real Gas using Clausius Parameter c, Reduced and Critical Parameters using the formula - Volume of Real Gas given CP = (((3*[R]*Critical Temperature)/(8*Critical Pressure of Real Gas))-Clausius Parameter c)*Reduced Molar Volume for Real Gas. This formula also uses Universal gas constant .
What are the other ways to Calculate Volume of Real Gas given CP?
Here are the different ways to Calculate Volume of Real Gas given CP-
  • Volume of Real Gas given CP=(Clausius Parameter b for Real Gas+(([R]*Critical Temperature For Clausius Model)/(4*Critical Pressure of Real Gas)))*Reduced VolumeOpenImg
Can the Actual Volume of Real Gas using Clausius Parameter c, Reduced and Critical Parameters be negative?
Yes, the Actual Volume of Real Gas using Clausius Parameter c, Reduced and Critical Parameters, measured in Volume can be negative.
Which unit is used to measure Actual Volume of Real Gas using Clausius Parameter c, Reduced and Critical Parameters?
Actual Volume of Real Gas using Clausius Parameter c, Reduced and Critical Parameters is usually measured using the Liter[L] for Volume. Cubic Meter[L], Cubic Centimeter[L], Cubic Millimeter[L] are the few other units in which Actual Volume of Real Gas using Clausius Parameter c, Reduced and Critical Parameters can be measured.
Copied!